INITIAL INSTALLATION
1 . Turn off the circuit breakers and the wall switch to the
fan supply line leads .
DANGER:
Failure to disconnect the power
supply prior to installation may result in serious injury or
death .
2 . Determine the mounting method to use .
Standard mounting
is best suited for ceilings 8 ft . or
higher . For taller ceilings you may want to use a longer
downrod (sold separately) .
Angle mounting
is best suited for angled or vaulted
ceilings . A longer downrod is sometimes necessary to
ensure proper blade clearance .
Important:
If using the
angle mount, check to ensure the ceiling angle is not
steeper than 16° .
Closemount-style
mounting is more suitable for
ceilings lower than 8 ft .
Flushmount installation
is not available for this item .
Standard Mounting
Flushmount
Closemount
Angle Mounting
3 . Ensure the blades (L) will be at least 30 in . from any
obstructions . Also check the downrod (A) length to
ensure the blades (L) will be at least 7 ft. above the floor.
3
7 ft.
Minimum
30 in.
Minimum
A
L