background image

 

 

ASSEMBLY INSTRUCTIONS 

 

GAS HOSE CONNECTIONS 

 
SR2201BI, SRR2201BI & SR4001BIS, SR4001BIR: Attach the hose to the manifold inlet nipple 
and  tighten  hose  clip

or  secure  the  hose  to  the  manifold  inlet  fitting  as  shown  in  FIG.01  & 

FIG.02 below. 
 
SR2, SRR2 & SR40, SR40: Attach the hose to the manifold 
inlet  fitting  with  a  national  standard  NG  connector  and  secure  the  hose  to  the  manifold  inlet 
fitting  as  shown  in  FIG.03  below. 

NOTE:

  Installation  and  service  must  be  performed  by  a 

qualified installer, service agency or your gas provider.

 

 

 

 

FIG.01 

FIG.02 

FIG.03 

Содержание SR2201BI/I2 Plus

Страница 1: ...r their mixture at 30mbar Injector SR2201BI I2 SRR2201BI I2 1 2 mm SR4001BIS I2 SR4001BIR I2 1 65mm AT DE SK CH Cat I3 B P 50 Butane propane or their mixture at 50mbar Injector SR2201BI I2 SRR2201BI I...

Страница 2: ...r kit unattended while using 6 In the event of a gas leak the appliance shall not be used or if alight turn off gas supply at the LPG cylinder or the nearest main shut off valve of city network gas An...

Страница 3: ...ce The dress guard is not supplied with the appliance the installer shall inform the user of the local rules in force and advise the fitting of the same dealer s or qualified installer s dress guard H...

Страница 4: ...I2E I2E 3 0mm 13 kW 946 g h The marking on the injector for example 1 20 indicates that the size of injector is 1 20mm LP Gas Regulator A gas regulator confirming to the national standard must be fit...

Страница 5: ...Igniter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M...

Страница 6: ...iter 1 29 Plate Control panel 1 09 Burner head 1 30 Bracket Burner Bowl 1 10 Leakage Protector 1 31 Frame 1 11 Windpipe 1 32 Screw M4F07 4 12 Nut Pilot Igniter 1 33 Nut M4 4 13 Washer 1 34 Screw M6F41...

Страница 7: ...6 SR2201BI I2 SR4001BIS I2 series exploded...

Страница 8: ...7 SRR2201BI I2 SR4001BIR I2 series exploded...

Страница 9: ...d inlet fitting as shown in FIG 01 FIG 02 below SR2201BII2 SRR2201BII2 SR4001BISI2 SR4001BIRI2 Attach the hose to the manifold inlet fitting with a national standard NG connector and secure the hose t...

Страница 10: ...rner kit onto the opening of your wooden table as shown in FIG 01 NOTE You may need to use and attach the optional table support bracket kit as shown in FIG 02 to secure the slats you saw off Adjust a...

Страница 11: ...perpendicular to the igniter box Lay the other logs in a teepee configuration over the first log It is important that the logs not lay directly on top of the burner By blocking the burner it will imp...

Страница 12: ...11 SR4001BIS I2 SR4001BIR I2...

Страница 13: ...e ground with screw Attach the manifold inlet fitting with the national standard NG connector supplied Connection of the NG supply to the appliance inlet should be made by a qualified installer Note F...

Страница 14: ...NSTRUCTIONS 74BUINSTALLATION OF THE LID When the appliance is not in use disconnect and take off the logs and close the lid to use as a normal table NOTE Be sure unit is cool before touching any of th...

Страница 15: ...ES Turn off the gas supply at the cylinder or main shut off valve of city network gas Do not try to light any appliance Do not touch any electrical switches Do not use any phone including cellular pho...

Страница 16: ...e area clear and free from combustible materials gasoline and other flammable vapors and liquids Installation and repair should be done by a qualified service person The appliance should be inspected...

Страница 17: ...regulator for details regarding fitting 3 Test for gas leaks Do a leak test each time the cylinder is installed whether or not it has been filled Check all other joints at least once a year lf the hos...

Страница 18: ...areas where the hose may be subjected to accidental damage 7 Open tank valve fully Turn the on off valve at the unit to the off position to pressurize the hose assembly Use a soapy water solution to...

Страница 19: ...y part has been under water Immediately call a qualified service technician to water WHAT TO DO IF YOU SMELL GAS Turn off the gas supply at the cylinder or main shut off valve of city network gas Do n...

Страница 20: ...s to ensure it is not cracked or damaged in any way INSPECTION AFTER REPAIR Any repairs must be performed by a qualified installer service agency or your gas provider 1 Check all the joints 2 Smell al...