3
SR2201BI/I2+ & SRR2201BI/I2+ BUILT-IN GAS FIRE BURNER KIT
SR2201BI &
SRR2201BI
Injector Orifice
Heat Input(Hs)
Gas Rate
I3+(28-30/37), I3B/P(30)
1.2mm
6.5 kW
473 g/h
I3 B/P(50)
1.02mm
6.5 kW
473 g/h
SR2 &
SRR2
I2L
1.95mm
6.5 kW
473 g/h
I2H/I2E/I2E+
1.72mm
6.5 kW
473 g/h
SR4001BIS/I2+ & SR4001BIR/I2+ BUILT-IN GAS FIRE BURNER KIT
SR4001BIS &
SR4001BIR
Injector Orifice
Heat Input(Hs)
Gas Rate
I3+(28-30/37), I3B/P(30)
1.65mm
12 kW
873 g/h
I3 B/P(50)
1.45mm
12 kW
873 g/h
SR40
&SR40
I2L
3.0mm
12 kW
873 g/h
I2H/I2E/I2E+
3.0mm
13 kW
946 g/h
The marking on the injector, for example,
“1. 20” indicates that the size of injector is 1.20mm.
LP Gas Regulator
A gas regulator confirming to the national standard must be fitted to the gas cylinder to provide
the appropriate gas pressure.
The outlet pressure of the LPG regulator must comply with the table below:
I3B/P(30)
I3B/P(50)
I3+
LPG
LPG
Butane
Propane
28~30mbar
50mbar
28~30mbar
37mbar
Do Not
use this appliance with an adjustable regulator. We suggest use this appliance with LP
gas cylinder of
5KG
. Cylinder
’s maximum height 70cm and maximum width 60cm
Instructions for assembly
Read these instructions through carefully before commencing assembly, and then follow them
step-by-step.