6
7
1.4 First aid instructions
• Inhalation of acid fumes: move to fresh air, keep warm
and calm. Consult a doctor if necessary.
• Acid splashing on skin: rinse splashes from the skin
immediately using plenty of water and take off
stained clothes.
• Acid exposure to eyes: rinse eyes immediately with
plenty of water, also under the eyelids. Consult a
doctor.
• If acid gets into mouth: rinse your mouth immediately
with plenty of water. A few glasses of water may be
drunk. Consult a doctor if necessary.
1.5 Restrictions on use
• The operator of the acid applicator must not be
under the influence of narcotics, alcohol or powerful
medications.
• In case of illness or disablement, the operation of
the machine must be authorized by the attending
physician.
• The acid applicator must not be used dry.
• Pumping inflammable liquids, liquids for human
consumption, or additives is forbidden.
• Do not pump acid that has been diluted with water
unless specifically permitted by the manufacturer.
2. Technical specifications
You can find the identity information of the machine in
the machine plate shown in the picture below. With this
information it is easier to maintain the product and order
spare parts.
Type the information of your machine to the pattern
below to be able to find it easily.
Spreader 4000 Spreader 6000
Operating voltage
12 V
12 V
Max. required
current
7 A
13 A
Max. pressure
3 bar
3 bar
Max. pumping
capacity
6 l/min
12 l/min
Weight
3,1 kg
3,1 kg