§ AT : Auto - Tuning
§
§ D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
o
of
f
e
ea
ac
ch
h
p
pa
ar
ra
am
me
et
te
er
r
If you press ENT key + key in the monitor screen or Function mode, you can enter
into Setup mode.
Generally Setup mode is used when user builds system. There are AT, HBA, BIAS, FILT,
C T, Communication mode parameter, LOCK1/LOCK2 & etc.
You can register & change Setting value by choosing , , keys.
3
-
6.
SETUP
MODE)
Initial Value :
OFF
Setting range
: OFF, ON
Contents
: Set whether At operates or not.
AT operation
: If you press ENT key after AT parameter
is On, AT operates & AT lamp flickers.
AT cancel
: AT is cancelled automatically as follows;
When AT parameter is Off
When SV is changed
Burn-out
When ADC error happens
Running is stopped
When you operate AT of 8 channels
simultaneously, channel parameter
becomes
¡ 1->2->¡ƒ->A¡–by pressing CH
key. When
¡ A¡–is shown , change Off in
the window SV into On. AT of all
channels operates by pressing ENT key
simultaneously.
When you operates AT in a channel
only, AT is On after you choose channel
by pressing CH key.
AT operates in the channel wanted in
that time.
C H
ZO N E
P V
S V
§ Rate : SV Rate
§ CHEN : Channel Enable
§ Anti Reset Windup
Initial Value
: 0 (Auto)
Setting range
: 0 (Auto) ~ 100 %
Contents
: Set the range of valid operation in
Integral operation to prevent fro m
overshoot by the effect of over-
integral.
C H
ZO N E
P V
S V
§ DISL : DI Select
C H
ZO N E
P V
S V
Initial Value :
OFF
Setting range
: 0 (0.0) ~ maximum range / min
Contents
: Set SV variation per min.
If it is Off, it doesn¡
fl
t operates.
If you change SV in RUN, Rate operates.
If you operate AT during Rate is
o perating, Rate is stopped at once and
AT operates as new SV.
Initial Value :
0
Setting range
: 0, 1
Contents
: Select whether you use DI function or
now
C H
ZO N E
P V
S V
Initial Value :
CONT
Setting range
: OFF, CONT, MONI
Contents
: Select whether you use each channel
a bout each Memory zone or not.
OFF :
Appoint a channel not used.
Not displayed a channel display in
setting Off
.
CONT :
become normal control condition.
MONI :
Displayed only PV value and Not
o perated to control.
C H
ZO N E
P V
S V