![Hanshen HC350D Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/hanshen/hc350d/hc350d_manual_3679977012.webp)
-
11
-
Table 5 Function on back panel
NO.
NAME
FUNCTION
1
Grounding Bolt
Connect this bolt for reliable grounding via wire or connect the input power supply
for reliable grounding.
2
Cooling Fan
For cooling inner calorific parts inside machine
3
Heating
Fuse
(
8A
)
The fuse will be broken down for protecting transformer while the regulator is
short circuit.
4
Power supply for
heating
For supplying DC 36V to regulator
(
cannot be used for other places, otherwise,
bear your own consequences
)
5
Power Switch
Be automatic power-off when welding machine is overload or malfunction.
Generally, the switch is to pull to the connection and to close or cut off input
power supply.
6
Nameplate
For description of parameters. Refer to it while operating
7
Power Cable Box
For connect with power supply in 380V
5.3 Wire Feeder Control Panel
A
V
手 动 送 丝
I N C H I N G
WELDING VOLT.ADJ.
电 压 调 整
WELDING CUR.ADJ.
电 流 调 整
FIG 6 Control Panel for Wire Feeder
Table 6 Function for Control Panel of Wire Feeder
NO
NAME
FUNCTION
1
Current Adjust
For welding current adjust. The relative value of current is shown
from 10 to 100 by scale while presetting current.
2
Feeding Wire by
Manual
For feeding the wire into torch before welding.
3
Voltage Adjust
For welding voltage adjustment.