Troubleshooting table
Page GB-30
Troubleshooting table
Malfunctions can occur in all electrical appliances. This does not necessarily mean
there is a defect in the appliance. For this reason, please check the tables to see if you
can correct the malfunction.
WARNING
Risk of electric shock in case of improper repair!
Never try to repair a defective or suspected defective appliance yourself. You can put
your own and future users’ lives in danger. Only authorised specialists are allowed to
carry out this repair work.
Problem
Possible cause
Solutions, tips, explanations
Compressor off, in-
terior light off.
No electricity to socket.
Check the socket with another appliance.
Mains plug is loose.
Check the tightness of the mains plug.
Compressor off, in-
terior light on.
The temperature controller
(13) is set to “0”.
Turn the temperature controller to a higher
position (see “Setting the temperature“ on
page GB-12).
Desired temperature has
been reached.
Further cooling not required. When the in-
side temperature rises, the compressor au-
tomatically turns on.
Appliance cools
too quickly.
The temperature controller is
set at too high a level.
Select a lower setting (see “Setting the tem-
perature“ on page GB-12).
The appliance
doesn’t cool suffi-
ciently.
The temperature controller is
set at too low a level.
Select a higher setting (see “Setting the tem-
perature“ on page GB-12).
Door not tightly closed or
door seal is not completely
tight.
See “Checking and cleaning the door seals”
on page GB-19.
The appliance is near a heat
source.
Place insulation plate between the applianc-
es or change location.
Food has been stored warm. Only store cooled foods.
Too many goods frozen.
Maintain maximum freezing capacity (see
“Technical data“ on page GB-35).
Thick ice layer in the freezer
area.
Defrost the freezer area (see page GB-19).
Ambient temperature too low
or too high.
Adjust the ambient temperature to the cli-
mate category (see “Technical data“ on
page GB-35).
Compressor seems defec-
tive.
Set the temperature controller to “7”. If the
compressor does not switch on within an
hour, please contact our service centre (see
page GB-32).
Содержание HKGK 17455 A2IWD
Страница 72: ......