29
Panel messages
6 4 System-related messages
Sensor A fault, sensor B fault
(Sensor A: Message code: M031*)
(Sensor B: Message code: M032*)
A temperature sensor or sensor circuit
has failed. Call for service.
Program memory failure**
(Message code: M022*)
At power-up, the system has failed the Program Checksum Test. This indicates
a problem with the fi rmware (operation program) and requires a service call.
The settings have been reset (Persistent Memory Error)**
(Message code: M021*)
Contact your dealer or service organization if this message appears on more than one
power-up.
The clock has failed**
(Message code: M020*)
Contact your dealer or service organization.
Confi guration error
The spa will not start up. Contact your dealer or service organization.
The GFCI test failed (system could not test the GFCI)
(Message code: M036*)
(North America only) May indicate an unsafe installation. Contact your dealer or
service organization.
A pump may be stuck On
(Message code: M034*)
Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER.
Contact your dealer or service organization.
Hot fault
(Message code: M035*)
A pump appears to have been stuck ON when spa was last powered POWER DOWN
THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.
* View chapter 6.8 for instructions on how to review the
fault log that corresponds with the message code.
** This message can be reset from the panel using the
CLEAR button (see the box on page 28).
Содержание TP 700
Страница 1: ...USER MANUAL TP 700 ...