27
Panel messages
control system
6 2 Heater-related messages
heater
The water fl ow is low
(Message code: M016*)
There may not be enough water fl ow
through the heater to carry the heat
away from the heating element. Heater
start up will begin again after about
1 minute. See "Flow Related Checks"
below.
The water fl ow has failed
(Message code: M017*)
There is not enough water fl ow through the heater to carry the heat away from the
heating element and the heater has been disabled. (See "Water Flow Checklist" on
chapter 3.2). After the problem has been resolved, reset the message**.
The heater may be dry**
(Message code: M028*)
Possible dry heater, or not enough water in the heater to start it. The spa is shut
down for 15 minute. Reset this message* to reset the heater start-up. (See "Water
Flow Checklist" on chapter 3.2)
* View chapter 6.8 for instructions on how to review the
fault log that corresponds with the message code.
** This message can be reset from the panel using the
CLEAR button (see the box on page 28).
The heater is dry**
(Message code: M027*)
There is not enough water in the heater to start it. The spa is shut down. After the
problem has been resolved, you must reset the message* to restart heater start up.
(See "Water Flow Checklist" on chapter 3.2)
Содержание TP 700