6
Fittings
(see page 60)
Installation tool
(see page 60)
Dimensions
(see page 61)
Installation example
Installation examples with measurements and pipe dimensions
can be found starting on page 62.
Technical Data
Operating pressure in front of the shower fitting:
max. 1 MPa
Recommended operating pressure:
0,3 – 0,5 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60 °C
Recommended hot water temp.:
42 °C
safety lock:
38 °C
Warning
: Exceeding this temperature can cause burns!
Safety Notes
• The shower system may only be used for bathing, hygienic
and body cleansing purposes.
• Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system without
proper supervision. Persons under the influence of alcohol or
drugs are prohibited from using this shower system.
• Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be kept
between the shower and you.
• The hot and cold supplies must be of equal pressures.
Operation
(see page 76)
Electrical connection
• The electrical connection may only be carried out by an
electrician!
• Preinstall electrcal power 230 V/N/PE/50 Hz (length: 0.3 m)
• The system must be protected via a leakage current protective
device (RCD/ FI) with a measurement difference current of ≤
30 mA.
Assembly basic kit
(see page 68)
Assembly Finish set
(see page 73)
•
Important!
The fitting must be installed, flushed and tested
after the valid norms.
• Where the contractor mounts the product, he should ensure
that the entire area of the wall to which the mounting plate is
to be fitted, is flat (no projecting joints or tiles sticking out), that
the structure of the wall is suitable for the installation of the
product and has no weak points.
• The enclosed screws and dowels are only suitable for con-
crete. For another wall constructions the manufacturer‘s indica-
tions of the dowel manufacturer have to be taken into account.
• The performance of the waste must be of sufficient size.
• The shower may only be connected following (downstream
from) a shut-off valve of the sanitary fitting.
Maintenance Instructions
• The non return valves must be checked regularly according to
DIN EN 1717 in accordance with national or regional regula-
tions (at least once a year).
Spare parts
(see page 76)
Service Replace illuminant
(see page 77)
Cleaning
(see page 78)
Electrician
The installation and testing work must be performed by a skilled
electrician in observance of VDE 0100 part 701 and IEC
60364-7-701.
English
Assembly see page 68
Содержание Rainmaker 28412180
Страница 62: ...62 62 50 l min Rain AIR Rain AIR XXL Whirl AIR Quattro...
Страница 64: ...64 64 50 l min Rain AIR Rain AIR XXL Whirl AIR Quattro...
Страница 66: ...66 66 50 l min Rain AIR Rain AIR XXL Whirl AIR Trio Quattro...
Страница 70: ...70 11 12 4x 4 5x90 13 14 1 2 3 Rainmaker 28412180...
Страница 71: ...71 15 16 6 mm 17 1 2 18 19 min 60 mm Rainmaker 28412180 28403000 26115000...
Страница 72: ...72 Rainmaker 28412180 28404000 26117000 15 16 6 mm 17 1 2 18 20 min 60 mm 19...
Страница 74: ...74 Rainmaker 26115000 26117000 28403000 28404000 6 1 3 2 7 8 9 10 5 SW 3 mm SW 4 mm 2 1 SW 4 mm SW 10 mm...
Страница 79: ...79 4 5 6...