7
English
Assembly
(see page 64)
Spare parts
(see page 71)
XXX = Colors
000 = Chrome Plated
250 = Brushed Gold-Optic
340 = Brushed Black Chrome
400 = White/Chrome Plated
Dimensions
(see page 66)
Flow diagram
(see page 66)
Test certificate
(see page 72)
Operation
(see page 69)
Hansgrohe recommends not to use as drinking water the first half litre flowing from
the tap in the morning, after the hygiene rinse is enabled, or after prolonged
non-use. If the fitting opens again after approx. 5 s, the viewing window must be
uncovered.
Hygiene rinse
To enable or disable the hygiene rinse, proceed as follows:
• Disconnect electrical plug connection between fitting and battery housing or
power pack. During this time, briefly reach with your hand into the detection
area of the sensor window so that the capacitor discharges.Restore the power
connection after 10 s.
• The LED blinks to indicate the software version (e.g. blinking once = software
version 1)
• wait for LED to go out
• Cover the sensor window completely with your hand or a white piece of paper
for 5 s - 10 s. (Water output starts for 5 s)
• Uncover the sensor window
• the currently enabled mode is indicated by the flashing of the LED: 1 x =
enabled, 2 x = disabled
• A subsequent change of operating mode is possible again after calibration
• The fitting only returns to normal operation 60 s after the last change of
operating mode
Permanent rinse
After setting the parameters for the hygiene rinse or making a net reset, wait for
approx. 90 s before you can enable the "Permanent rinse" function.
• cover sensor window completely with your hand or a white piece of paper
• The fitting opens for approx. 5 s and immediately closes again. If the fitting
opens again after approx. 5 s, the viewing window must be uncovered.
• Permanent rinse is enabled for approx. 180 s and can be interrupted at any time
by a movement in the field of vision.
Thermal disinfection
• Thermal disinfection pursuant to process sheet DVGW W 551 (≥ 70°C /
> 3 min) must only be carried out by qualified personnel.
• Risk of scalding with thermal disinfection!
• The cold water feed must be locked during thermal disinfection. Afterwards,
"Permanent rinse" can be enabled.
Net reset
A net reset causes the fittings to re-adjust.
• Interrupt the voltage supply to the fittings
• Briefly reach into the field of vision of the fittings to cause the capacitor to
discharge
• Wait for approx. 10 s, then plug the connectors in again
• The fittings will re-adjust during the next 30 s. Do not reach into the field of vision
during this period of time.
Disposal of waste batteries and old Electrical &
Electronic Equipment
(applicable in the European Union
and other European countries with separate collection
systems).
This symbol on the battery, the product or the packaging indicates that the battery
or the product shall not be treated as household waste. By ensuring the battery or
product are disposed of correctly, you will help prevent potentially negative
consequences for the environment and human health. The recycling of the materials
will help to conserve natural resources. To ensure that the battery or product will be
treated properly, hand over the product at end-of-life to the applicable collection
point for the recycling of batteries, electrical and electronic equipment. For more
detailed information about recycling of this product or battery, please contact your
local Civic Office, your household waste disposal service or the shop where you
purchased the product.
Содержание Focus 31171 Series
Страница 64: ...64 3 Nm 2 1 2 1 6 7 3 5 ca 670 mm 600 mm 1 2 0 4 SW 19 mm 4 Nm SW 10 mm ...
Страница 67: ...67 8 11 2 1 10 9 1 2 7 5 6 3 2 2 1 1 4 SW 10 mm SW 19 mm SW 19 mm 4 Nm SW 10 mm SW 22 mm SW 22 mm 2Nm ...
Страница 68: ...68 3 1 2 ca 5 10 sec ca 5 sec ca 60 sec 1 2 1 CR P2 6 V Lithium 2 4 3 4 ...