Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children may only use the product unsupervised if they have been suitable
instructed and trained to use the product safely and to understand the risks of
improper operation.
Only the battery housing with battery CR-P2 or power pack HG No.
30589310 supplied by Hansgrohe may be connected to the electrical
connection cable of the fittings.
A damaged connecting line must not be replaced. The transformer may no
longer be used.
The transformer and its mains plug may only be installed or plugged in in dry
interior rooms outside of the protected zones.
The transformer must not be installed in protection zones 0 or 1.
The wall socket must be outside of the protected zones.(see page 64, Fig. 5)
The fitting may be installed in protected zone 2.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• Leave enough space above the tap for servicing. (min. 200 mm)
• The fittings must not be installed on washstands with raised edge. (see page 64)
• At the start of operation, or after maintenance, function of the faucet may be
delayed due to reflections during adjustment of the operating distance. The
faucet will automatically calibrate itself. The self-calibration will start after
10-15 minutes.
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Electrical installation
Electrician
The installation and test work must be performed by an authorized electrician
under consideration of DIN VDE 0100 part 701 / IEC 60364-7-701.
Electrical connection
Voltage supply: 230 V AC ± 10 %/ 50- 60 Hz
The circuit must be protected via a ground fault protector (RCD / FI) with a
measured differential current of ≤ 30 mA. The proper function of this protective
device must be checked at regular intervals.
Any work may only be carried out in a de-energized state. Here, the voltage
supply must be safely separated via the main switch or mains plugs.
The wall socket must be outside of the protected zones.(see page 64, Fig. 5)
Adjustment
This mixer has the following feature: background fade-out with integrated range
adjustment, that means the mixer is automatically adjusted on to the local conditions
(washbasin, brightness, reflection) by the sensory mechanism.
Battery operation
The indicator LED signals that the battery must be changed.
Battery voltage ≤ approx. 5.5 V: The indicator LED in the sensor window blinks
when the fitting is operated, water withdrawal continues to be possible
Battery voltage ≤ approx. 5.5 V: The indicator LED in the sensor window lights
continuously, water withdrawal is no longer possible, the battery must be replaced.
Attention! After insertion of the battery, the fitting should not be activated for
approx. 30 seconds. This time is required for self-adjustment.
Replacement, installation and disposal of batteries is subject to the regulations speci-
fied in EN 60335-1 Appendix 3 Section 7.12.
Power supply pack operation
For the replacement of a power supply pack, the procedure corresponds to the
replacement of a battery.
Normal operation
The range of the detection area or the removal of the switch-on/off point from the
fittings depends on the ambient optical conditions (for example, the shape and
reflection of the washstand and the ambient light) as well as on the shape, the size,
the speed and the reflection of the object that was brought into the detection area.
The detection area of the fittings or the distance of the switch-on/off point from the
fittings is approx. 160 to 200 mm in normal operation. The detection of dark (for
example grey-black) objects by the fittings is inadequate because of their low
reflection. The range of the detection area or the distance of the switch-on/off point
can be smaller than 160 mm. The detection of bright or reflecting objects by the
fittings is very good as a result of their high reflectivity. The range of the detection
area or the distance of the switch-on/off point can be greater than 200 mm. Strong
light sources should not shine directly on the sensor window of the fittings. Drops of
water or condensed water on the sensor window of the fittings can initiate
unintended running of the water.
Range setting for infrared proximity electronics
It may be necessary to reduce the range of the infrared proximity electronics by
manual mode switching when the fittings are connected to very small or highly
reflecting washstands. The following two modes can be selected:
• Maximum range (factory setting)
• Reduced range (maximum range reduced by approx. 50 mm)
The LED behind the sensor window signals which mode the fittings are currently in:
• Short blinking when the fittings are closed = "reduced range"
• No blinking when the fittings are closed = "maximum range"
Perform the following steps to change from "maximum" to "reduced" range or vice
versa:
• Disconnect electrical plug connection between fitting and battery housing or
power pack. During this time, briefly reach with your hand into the detection
area of the sensor window so that the capacitor discharges. Restore the power
connection after 10 s.
• The LED blinks to indicate the software version (e.g. blinking once = software
version 1)
• Wait for calibration to finish (The light emitting diode lights continuously for 10 s)
• cover sensor window completely with your hand or a white piece of paper
(Water output starts for 5 s)
• Uncover the sensor window
• The LED indicates the currently activated mode by blinking: Once = "maximum
range", twice = "reduced range"
• The LED then lights permanently until the calibration of the just set range of the
infrared proximity switch has completed
• Range setting can be repeated within the next 10 s
• When the LED goes off again, the fittings are ready for operation
Technical Data
Operating pressure:
max. 0,8 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa
flow pressure:
max. 42°C
Follow-up time:
1 - 2, s
Automatic switching-off:
after 10 s
battery:
CR-P2 / 6 V Lithium
transformer:
230 V AC ± 10 % / 50 – 60 Hz / 20 mA
Protection category:
IPX5
installation site of type plate:
see page 71
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
(see page 65)
The desired maximum temperature for example max. 38°C can be pre-set thanks to
the safety function.
Maintenance
(see page 67)
The check valves must be checked regularly according to EN 806-5 in accordance
with national or regional regulations (at least once a year).
Cleaning
(see page 72)
Never use high pressure cleaners or steam cleaners to clean the fittings.
Cleaning washbasin
(see page 68)
After setting the parameters for the hygiene rinse or making a net reset, wait for
approx. 90 s before you can enable the "Clean wash basin" function.
Protected area
(see page 64)
Exchange battery
(see page 68)
0, 1, 2
Содержание Focus 31171 Series
Страница 64: ...64 3 Nm 2 1 2 1 6 7 3 5 ca 670 mm 600 mm 1 2 0 4 SW 19 mm 4 Nm SW 10 mm ...
Страница 67: ...67 8 11 2 1 10 9 1 2 7 5 6 3 2 2 1 1 4 SW 10 mm SW 19 mm SW 19 mm 4 Nm SW 10 mm SW 22 mm SW 22 mm 2Nm ...
Страница 68: ...68 3 1 2 ca 5 10 sec ca 5 sec ca 60 sec 1 2 1 CR P2 6 V Lithium 2 4 3 4 ...