background image

2

Technical Information

Recommended water pressure 

15 - 75 PSI

Max. water pressure 

145 PSI

Recommended hot water temp. 

120° - 140° F*

Max. hot water temp 

176°F*

Flow rate 

1.5 GPM

Hole size in mounting surface 

1⅜"

Max. depth of mounting surface 

1⅝"

Battery 

CR-P2 / 6 V Lithium

Automatic shutoff 

after 1 minute**

*Please know and follow all applicable local plumbing 
codes when setting the temperature on the water heater.
**This is the maximum amount of time the faucet will run 
while a hand is within range of the sensor.

English

Installation Considerations

•  For best results, Hansgrohe recommends that 

this unit be installed by a licensed, professional 
plumber.

•  Please read over these instructions thoroughly be-

fore beginning installation.  Make sure that you 
have all tools and supplies needed to complete 
the installation.

•  Keep this booklet and the receipt (or other proof 

of date and place of purchase) for this product in 
a safe place.  The receipt is required should it be 
necessary to request warranty parts.  

•  Flush the hot and cold supplies thoroughly 

before installing the faucet.  Damage to the 
faucet caused by debris is not covered under the 
warranty.

•  The hot and cold supplies should be of equal 

pressure.

•  The faucet should 

not

 be used with a continuous 

flow water heater.  

•  Do not install the faucet on a sink with a raised 

edge.

•  Strong light sources should not shine directly on 

the sensor window of the faucet.  

•  The faucet should only be used with the battery 

pack supplied by Hansgrohe.  Do not attempt to 
use any other battery pack. 

•  The faucet incorporates automatic range adjust-

ment -- the sensor automatically adjusts itself to 
local conditions (lavatory, brightness, etc.)  

•  The distance between the switch on/off point 

to the faucet is approx. 6¼" - 8" under normal 
conditions.  The detection area may be less for 
dark, non-reflective objects, or greater for bright, 
highly reflective objects. 

•  If the sink is very small or highly reflec-

tive, follow the range reduction instruc-

tions

. When the faucet is in reduced range 

mode, the LED in the sensor window will flash 
while the faucet is not in use.  

•  Drops of water or condensation on the sensor 

window may cause the faucet to run.

•  If the LED in the sensor window flashes while the 

faucet is in use, the battery is low, but the faucet 
may still be used.  If the LED stays on, the faucet 
will not run, and the battery must be changed. 

•  The spray pattern will be unattractive 

immediately after installation or service, 

due to air in the faucet.  After the faucet 

is used 10 - 15 times, the spray pattern 

will clear.

•  At the start of operation, or after maintenance, 

function of the faucet may be delayed due to 
reflections during adjustment of the operating 
distance. The faucet will automatically calibrate 
itself. The self-calibration will start after 10-15 
minutes.

Содержание AXOR Starck Series

Страница 1: ...Starck 10101001 Starck 10106001 Starck X 10170001 10175001 EN Installation User Instructions Warranty FR Instructions de montage Mode d emploi Garantie ES Instrucciones de montaje Manejo Garant a...

Страница 2: ...on a sink with a raised edge Strong light sources should not shine directly on the sensor window of the faucet The faucet should only be used with the battery pack supplied by Hansgrohe Do not attempt...

Страница 3: ...es sources lumineuses puissantes ne doivent pas clairer directement sur la fen tre de capteur du robinet Le robinet doit tre utilis uniquement avec la batterie fournie par Hansgrohe N utilisez aucune...

Страница 4: ...tro de gama del sensor No permita que fuentes de luz muy intensas iluminen directamente la ventana del sensor del grifo El grifo s lo debe usarse con el paquete de bat er as que suministra Hansgrohe N...

Страница 5: ...01 10106001 Starck X 10170001 10175001 Do not install this faucet on a sink with a raised lip N installez pas le robinet sur un vier muni d un rebord sur lev No instale el grifo en un fregadero con bo...

Страница 6: ...6 Starck 10101xx1 10106xx1 Tools Required Outiles Utiles Herramientas tiles Starck X 10170001 10175001 5 4 4 2 3 1 17 11 G 1 2 2 2 max 1 4 10 mm 19 mm...

Страница 7: ...mantenimiento las v lvulas de retenci n art culo 96456000 deben retirarse y verificarse anualmente 98801000 98809000 98867000 95377000 95654000 96456000 13961000 95379000 CR P2 6V Lithium Hansgrohe SE...

Страница 8: ...e mounting surface Install and tighten the mounting nut Tighten the tensioning screws Connect the adapters to the stops Install the filters Connect the hoses to the adapters Use two wrenches Do not al...

Страница 9: ...los filtros Conecte las mangueras a los adaptadores Use dos llaves No permita que las mangueras se tuerzan Installation Positionnez le robinet sur la surface de montage Installez et serrez l crou de m...

Страница 10: ...et the spray pattern may be unattractive for the first 10 15 uses after installation or service Models with manual temperature adjust ment only Pull the temperature lever forward to make the water coo...

Страница 11: ...rifo del paquete de bater as Retire la tuerca de la parte posterior del grifo Connectez le c ble d alimentation du robinet la batterie Ouvrez les conduites d alimentation en eau chaude et froide Retir...

Страница 12: ...er cooler backward to make it warmer Dry any drops of water from the faucet or mounting surface Replace the faucet body Replace the screw Turn the water supplies on Reconnect the power cable Wait 30 s...

Страница 13: ...cable de alimentaci n Espere 30 segundos Coloque la mano delante del grifo para encenderlo Retirez le corps du robinet Tournez la vis de contr le de la temp rature vers l avant pour que l eau soit plu...

Страница 14: ...once to indicate that it is in the maximum range mode When the LED stays on cover the sensor window with your hand or with a white card for 20 40 seconds to reset the electronics If the card or hand...

Страница 15: ...mientras el sensor se vuelve a calibrar Cuando el LED se apague el grifo estar listo para usar R duire la port e du capteur Le capteur est r gl sur la port e maximale en usine Si le robinet est utilis...

Страница 16: ...possible de faire couler l eau La DEL t moin de la fen tre d tectrice est allum e en continu il n est plus possible de faire couler l eau la pile doit tre remplac e El diodo piloto en la ventana del s...

Страница 17: ...17 Changethesprayformer Changezleformedejet Cambie laformade chorro 2 mm 2 mm 1 2 4 3...

Страница 18: ...18 Clean the sink Nettoyage du lavabo Limpiar el lavabo Cleaning Nettoyage Limpieza 1 2 ca 5 sec...

Страница 19: ...be removed and checked yearly Las v lvulas de retenci n deben retirarse y verificarse anualmente Les clapets de non retour article n 96456000 doivent tre retir s et v rifi s chaque ann e Maintenance E...

Страница 20: ...ampoos can cause damage Rinse the product with clean water after each use Residue from basin tub tile cleaner can cause damage to faucets and fittings Immediately rinse any overspray from the Hansgroh...

Страница 21: ...ados Evite la acumulaci n de restos de jab n o sarro limpiando el producto Hansgrohe cuando sea necesario Seleccione un agente de limpieza dise ado espec ficamente para el tipo de producto No use esto...

Страница 22: ...respect to Hansgrohe Commercial products and ii for 5 years with respect to Axor products THIS WARRANTY DOES NOT COVER AND HANSGROHE WILL NOT PAY FOR A Conditions malfunctions or damage not resulting...

Страница 23: ...r rights that vary from state to state TO THE EXTENT PERMITTED BY LAW ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE EXPRESS WARRANTY...

Страница 24: ...Hansgrohe Inc 1490 Bluegrass Lakes Parkway Alpharetta GA 30004 Tel 800 334 0455 Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90423026 Revised 04 2014...

Отзывы: