2
Technical Information
Recommended water pressure
15 - 75 PSI
Max. water pressure
145 PSI
Recommended hot water temp.
120° - 140° F*
Max. hot water temp
176°F*
Flow rate
1.5 GPM
Hole size in mounting surface
1⅜"
Max. depth of mounting surface
1⅝"
Battery
CR-P2 / 6 V Lithium
Automatic shutoff
after 1 minute**
*Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
**This is the maximum amount of time the faucet will run
while a hand is within range of the sensor.
English
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• Please read over these instructions thoroughly be-
fore beginning installation. Make sure that you
have all tools and supplies needed to complete
the installation.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
• Flush the hot and cold supplies thoroughly
before installing the faucet. Damage to the
faucet caused by debris is not covered under the
warranty.
• The hot and cold supplies should be of equal
pressure.
• The faucet should
not
be used with a continuous
flow water heater.
• Do not install the faucet on a sink with a raised
edge.
• Strong light sources should not shine directly on
the sensor window of the faucet.
• The faucet should only be used with the battery
pack supplied by Hansgrohe. Do not attempt to
use any other battery pack.
• The faucet incorporates automatic range adjust-
ment -- the sensor automatically adjusts itself to
local conditions (lavatory, brightness, etc.)
• The distance between the switch on/off point
to the faucet is approx. 6¼" - 8" under normal
conditions. The detection area may be less for
dark, non-reflective objects, or greater for bright,
highly reflective objects.
• If the sink is very small or highly reflec-
tive, follow the range reduction instruc-
tions
. When the faucet is in reduced range
mode, the LED in the sensor window will flash
while the faucet is not in use.
• Drops of water or condensation on the sensor
window may cause the faucet to run.
• If the LED in the sensor window flashes while the
faucet is in use, the battery is low, but the faucet
may still be used. If the LED stays on, the faucet
will not run, and the battery must be changed.
• The spray pattern will be unattractive
immediately after installation or service,
due to air in the faucet. After the faucet
is used 10 - 15 times, the spray pattern
will clear.
• At the start of operation, or after maintenance,
function of the faucet may be delayed due to
reflections during adjustment of the operating
distance. The faucet will automatically calibrate
itself. The self-calibration will start after 10-15
minutes.