• The instrument will continuously update the concentration on the display. The value will be 

displayed blinking. When the reading is under range “----” symbol appears blinking.

 

• The titration curve can be viewed during a titration by pressing 

Plot ON

. Press 

Plot OFF

 to 

return to the titration screen.

• At the end of the titration, the concentration is displayed in the selected unit. The titration curve 

can be viewed by pressing 

Plot ON

.

 

• Press the 

LOG

 key to save the result and the titration curve. A message will be displayed for a 

few seconds indicating the amount of free log space.

• Press 

Restart

 to begin a new titration or the 

ESC

 key to return to the titration menu.

Содержание HI84534

Страница 1: ...INSTRUCTION MANUAL HI84534 Titratable Acidity Minititrator pH Meter For Vinegar...

Страница 2: ...a Hanna Instruments product Please read this instruction manual carefully before using this meter This manual will provide you with the necessary information for correct use of this meter as well as...

Страница 3: ...PUMP 12 5 TITRATOR SETUP 13 5 1 ELECTRODE 13 5 2 DOSING PUMP 14 6 SETUP MENU 17 6 1 CONCENTRATION UNIT 17 6 2 CALIBRATION TIMEOUT 17 6 3 pH RESOLUTION 17 6 4 TEMPERATURE UNIT 18 6 5 TIME 18 6 6 DATE 1...

Страница 4: ...E PREPARATION 27 9 2 PROCEDURE 27 9 3 ERRORS AND WARNING MESSAGES 29 10 pH MEASUREMENT 30 11 LOGGING 31 11 1 TITRATOR 31 11 2 METER 32 11 3 PC INTERFACE AND DATA TRANSFER 33 12 TITRATOR GLP INFORMATIO...

Страница 5: ...egar HI1131B pH electrode HI7662 T Temperature probe HI7082 Electrode fill solution 30 mL 100 mL beakers 2 pcs Tube set aspiration tube with titrant bottle cap and dispensing tube with tip Dosing pump...

Страница 6: ...ectrode and pump 2 1 PRINCIPLE OF OPERATION Vinegar acidity is determined by neutralization of all available hydrogen ions present in the sample with a strong base solution H HO H2 O In an ideal solut...

Страница 7: ...type of vinegar depends on what liquid the ethanol has been fermented in White vinegar is made a vodka type liquor made from grain while apple cider vinegar is made from apples and balsamic vinegarism...

Страница 8: ...to pH 8 2 Pump speed 10 mL min Stirring speed 600 rpm Data storage Up to 200 titrations pH mV meter pH range 2 0 to 16 0 pH 2 00 to 16 00 pH pH resolution 0 1 pH 0 01 pH pH accuracy 0 01 pH pH calibra...

Страница 9: ...2 T Power supply 12 Vdc power adapter Dimension 235 x 200 x 150 mm 9 2 x 7 9 x 5 9 Weight 1 9 kg 67 0 oz Environment 0 to 50 C 32 to 122 F max 95 RH non condensing REQUIRED REAGENTS Code Description H...

Страница 10: ...Temperature probe 7 pH electrode 8 Electrode holder 9 Beaker 10 Power switch 11 USB connector PC interface 12 USB connector storage interface 13 Power adapter 14 BNC electrode connector 15 Temperatur...

Страница 11: ...s to scroll the information displayed while viewing a help screen or to move between the options from the instrument s Setup CAL used to access the electrode and pump calibration options HELP used to...

Страница 12: ...ATC automatic or MTC manual 8 Temperature reading 9 Indicates the parameter can be modified 4 5 DOSING PUMP The dosing pump is based on a valve that automatically moves the titrant between the titrant...

Страница 13: ...on in the protective cap with a few drops of HI70300 or HI80300 storage solution Follow the preparation procedure section before taking measurements Note Never store the pH electrode in distilled or d...

Страница 14: ...on the pump 2 Once the syringe is in place lower the barrel until it sits flush on the holder Puttheo ringandsyringe fixingnutoverthesyringe 3 andturnclockwisetosecureitinplace 4 Place the valve on t...

Страница 15: ...The prime cycle is used to fill the syringe before starting a set of titrations Two rinse cycles of the syringe are shown in the figure below The dispensing tube is connected to the top of the valve...

Страница 16: ...rt A minimum of 3 rinses is recommended to ensure all of the air bubbles have been removed To stop the prime cycle press Stop To pause the prime cycle press Pause to continue press Continue Note The P...

Страница 17: ...C to return to the main screen 6 1 CONCENTRATION UNIT Option AA or g L AA Press the corresponding virtual option key to select the concentration unit AA g 100 mL Acetic Acid g L AA g L Acetic Acid 6 2...

Страница 18: ...new value or the ESC key to return to the setup menu without saving the changes 6 6 DATE Press the Modify key to change the date and date format Press Format to cycle between the available date format...

Страница 19: ...screen and CSV files 6 10 LCD CONTRAST Option 0 to 15 Press Modify to change the display s contrast Use the keys or keys to increase or decrease the value Press Accept to confirm the new value or the...

Страница 20: ...rmation are not available 6 13 TUTORIAL Option Enable or Disable If enabled additional information will be displayed during the calibration and titrations 6 14 METER INFORMATION Press Select to view t...

Страница 21: ...may be used Note The HI84534 will not accept other pH buffers for calibration Pour small quantities of selected buffer solutions into clean beakers For accurate calibration use two beakers for each bu...

Страница 22: ...med press the ESC key to exit and save the one point calibration Two Point Calibration Remove the electrode holder with electrodes from the top of the beaker Place the second beaker with calibration b...

Страница 23: ...s the STIR key If necessary press the keys in order to select a different buffer value Note Previously confirmed buffers are removed from the list of available buffers The symbol will be shown on the...

Страница 24: ...tency exists between the current and the previous calibration Clear the previous calibration by pressing Clear and proceed with calibration from the current calibration point The instrument will keep...

Страница 25: ...tte to add exactly 2 mL of HI84534 55 calibration standard to a clean beaker Note Failure to use a clean pipette will result in erroneous readings Fill the beaker up to the 50 mL mark with the distill...

Страница 26: ...alibration or Stop to abort it At the end of the calibration Calibration Completed appears on display To repeat the calibration press Restart or the ESC key to return to the main screen 8 3 ERRORS AND...

Страница 27: ...50 mL with distilled or deionized water 9 2 PROCEDURE Place the dispensing tip over a waste beaker and press Start The pump will dispense a small amount of titrant when it resets Place the stir bar in...

Страница 28: ...pressing Plot ON Press Plot OFF to return to the titration screen At the end of the titration the concentration is displayed in the selected unit The titration curve can be viewed by pressing Plot ON...

Страница 29: ...xceeds the specified limits the message Wrong input will be displayed and the pH or temperature reading will blink Another titration can be started by pressing Restart If an error with the stirrer occ...

Страница 30: ...reading A message indicating the free log space will be displayed for a few seconds Ifmeasurementsaretakensuccessivelyindifferentsamples itisrecommendedtorinsetheelectrodesthoroughly withdeionizedordi...

Страница 31: ...If the saved concentration was out of range the or symbols are displayed in front of the reading Press Delete to delete the selected log from the memory Press Del All to delete all records Press Info...

Страница 32: ...letetherecordorNotoreturntothepreviousscreen Deletingasinglerecordwillrenumber the list of records If the titrator log is empty the message No records available will be displayed 11 2 METER The instru...

Страница 33: ...a USB stick using the export function from the log recall menu Two text files are transferred on the USB stick These files can be used for further analysis on a PC The logged data can also be transfer...

Страница 34: ...displayed 12 2 ELECTRODE The pH meter GLP screens display the last pH calibration data Press Electrode to view information regarding electrode calibration The following items are included in electrod...

Страница 35: ...f range Check cable connection to meter and verify protective cap is off Check the quality of the sample Clean the electrodes Refill with fresh fill solution The meter does not accept the pH buffer so...

Страница 36: ...rd or contact the vendor Error xx message is displayed Internal error Power off the meter and then power it on again If the error persists contact the vendor Stirrer error message is displayed at the...

Страница 37: ...B pH electrode HI7662 T Temperature probe ELECTRODE FILL SOLUTION HI7082 Fill solution for HI1131B 4 x 30 mL ELECTRODE STORAGE SOLUTION HI70300L Electrode storage solution 500 mL ELECTRODE CLEANING SO...

Страница 38: ...roduced by the user to the supplied equipment may degrade the meter s performance For yours and the meter s safety do not use or store the meter in hazardous environments WARRANTY HI84534 is warranted...

Страница 39: ...Hanna Instruments reserves the right to modify the design construction or appearance of its products without advance notice...

Страница 40: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN84534 Printed in ROMANIA...

Отзывы: