15 Accessories

13.  ACCESSORIES

Ordering Information

Product Description

Conductivity Solutions

HI7030M 

or 

HI7030L

12880 µS/cm standard solution, 230 or 500 mL

HI7031M 

or 

HI7031L

1413 µS/cm standard solution, 230 or 500 mL

HI7033M 

or 

HI7033L

84 µS/cm standard solution, 230 or 500 mL

HI7034M 

or 

HI7034L

80000 µS/cm standard solution, 230 or 500 mL

HI7035M 

or 

HI7035L

111800 µS/cm standard solution, 230 or 500 mL

HI7037M 

or 

HI7037L

100 % NaCl seawater salinity standard solution, 230 or 500 mL

HI7039M 

or 

HI7039L

5000 µS/cm standard solution, 230 or 500 mL

Other Accessories

HI60501

PVC immersion electrode holder

HI60501-0

O-rings for 

HI60501

 electrode holder

HI60501-2

PVC protective end cap, inside height 68 mm (2.6”)

HI60503

PVDF immersion electrode holder

HI60503-2

PVDF protective end cap, inside height 68 mm (2.6”)

HI605011

PVC mounting flange

HI60542

In-line electrode holder, direct pipe installation

HI76510-05

Patch cable, 5 m (16’5”)

HI76510-10

Patch cable, 10 m (32’9”)

HI76510-15

Patch cable, 15 m (49’2”)

HI76510-25

Patch cable, 25 m (82’)

HI76510-50

Patch cable, 50 m (164’)

BL120-400

Flow-cell probe adapter kit

BL120-401

Flow-cell valve

BL120-402

Flow-cell tubing,10 m (32’9”)

BL120-410

Flow cell

BL120-463

Flow-cell kit for Ø 63 mm (2.5”) pipe

BL120-475

Flow-cell kit for Ø 75 mm (3”) pipe

BL120-500

Probe fitting kit

BL120-550

Probe saddle for Ø 50 mm (2”) pipe, 1 ¼” thread

BL120-563

Probe saddle for Ø 63 mm (2.5”) pipe, 1 ¼” thread

BL120-575

Probe saddle for Ø 75 mm (3”) pipe, 1 ¼” thread

For additional accessories information contact your local sales office.

Содержание HI7630-28

Страница 1: ...4805 0 to 30 mS cm T 0 to 50 C p max 6 bar SN XXXXXXXXXXXX HI7630 2800 Conductivity and Temperature Industrial Smart Probes Please scan the QR code or follow the link to download the HI510 controller...

Страница 2: ...intenance 14 13 Accessories 15 14 Abbreviations 16 Certification 16 Recommendations for Users 16 Warranty 16 Dear Customer Thank you for choosing a Hanna Instruments product Please read this instructi...

Страница 3: ...ons detailed in this manual 3 GENERAL DESCRIPTION INTENDED USE HI7630 28 and HI7630 48 are Conductivity and Temperature probes designed to be paired with the HI510 Universal Process Controller The pro...

Страница 4: ...conductivity probes can be installed directly in line immersed in a tank or in a flow cell and are suited for continuous measurement of conductivity and associated parameters required in applications...

Страница 5: ...h standard solution Process Single point Temperature Range 0 0 to 50 0 C 32 0 to 122 0 F Accuracy 0 5 C 1 0 F Calibration Single point offset controller setting Temperature compensation mode Linear Na...

Страница 6: ...ion Salinity Single point with standard solution Resistivity Single point Process Single point Temperature Range 0 0 to 100 0 C 32 0 to 212 0 F Accuracy 0 5 C 1 0 F Calibration Single point offset con...

Страница 7: ...189 mm 7 4 Four Ring Probes HI7630 48zz 28 mm 1 1 72 mm 2 8 50 mm 2 12 mm 0 5 3 4 NPT 216 mm 8 5 HI7630 4800 216 mm 8 5 Align the pins and key then push the plug into the socket Rotate the collar to...

Страница 8: ...essibility for maintenance when selecting placement Typical installation examples with mounting accessories Accessories are sold separately In line mounting and flow cell installation require that the...

Страница 9: ...PT 2 Vent hole 3 O ring 4 Probe Tank immersion with submersible electrode holder I II III 1 2 4 3 5 6 7 9 8 1 Probe cable 2 Cable gland 3 Electrode holder cap 4 Adjustable immersion level 5 Electrode...

Страница 10: ...3 and cable gland on top 2 The cable is shielded inside the holder to prevent any damage to the insulation F Tighten the cable gland 2 step III and slide the cap 3 back onto the electrode holder 5 Fl...

Страница 11: ...n the board 4 Position excess cable through the cable gland before tightening the nut 5 Remove the ground screw and hardware located below the PROBE connector and attach ground lead g COMM B A IN1 IN2...

Страница 12: ...oss contamination when a two point calibration is required use two beakers one for rinsing the probe and the other for calibration Go to Probe Settings in Channel Setup and set Meas Mode to EC Procedu...

Страница 13: ...ed in conductivity EC Meas Mode The user can subsequently change Meas Mode to RES to measure in resistivity units M cm Ultrapure water self ionizes into H and OH ions and has a conductivity of 0 055 S...

Страница 14: ...ccurate readings Remove and inspect the probe during scheduled service intervals Dry clean the sensor with a soft bristle brush to loosen any debris For a more thorough cleaning Use a cloth and warm w...

Страница 15: ...1 2 PVC protective end cap inside height 68 mm 2 6 HI60503 PVDF immersion electrode holder HI60503 2 PVDF protective end cap inside height 68 mm 2 6 HI605011 PVC mounting flange HI60542 In line electr...

Страница 16: ...oduced by the user to the supplied equipment may degrade its performance Do not use or store the product in hazardous environments WARRANTY The probes are warrantied for six months against defects in...

Отзывы: