Range

0.0-5.0 g/L

Resolution

0.1 g/L

Precision

SD ±0.1 g/L @ 2.0 g/L

Light Source

Tungsten lamp with narrow band interference filter @ 525 nm

Light Detector

Silicon Photocell

Method

The reaction between Tartaric Acid and the reagents causes a yellow/

orange red tint in the sample.

Environment

0 to 50°C (32 to 122°F); max 95% RH non-condensing

Battery Type

4 x 1,5 volt AA batteries / 12 to 20 VDC through voltage adapter

Dimensions

225 x 85 x 80 mm (8.7 x 3.3 x 3.1")

Weight

500 g (17,6 oz.)

REQUIRED REAGENTS

Code

Description

Quantity/test

HI 83748A-0

Tartaric Acid Reagent A

5 mL

HI 83748B-0

Tartaric Acid Reagent B

6 drops

SPECIFICATIONS

Precision is how closely repeated measurements agree
with each other.  Precision is usually expressed as
standard deviation (SD). Accuracy is defined as the
nearness of a test result to the true value.
Although good precision suggests good accuracy,
precise results can be inaccurate. The figure explains
these definitions.
In a laboratory using a standard solution of 2.0 g/L
tartaric acid and a representative lot of reagent, an
operator obtained with a single instrument a standard
deviation of 

0.1 mg/L.

PRECISION AND ACCURACY

16

Battery replacement must only take place in a non-
hazardous area.
The blinking “ ” will appear when the batteries power
gets low.
When batteries are completely discharged, “0% bAtt”
will appear and after two seconds the instrument is
switched off.
Remove the battery cover from the bottom of the
instrument and change the old batteries with 4 fresh
1.5V batteries, paying attention to the correct polarity.
Replace the cover.

BATTERIES REPLACEMENT

REAGENT SETS
HI 83748-20

Tartaric Acid reagents set for wine (20 tests)

OTHER ACCESSORIES
HI 740027P

1.5V AA batteries (10 pcs)

HI 731318

Tissue for wiping cuvets (4 pcs)

HI 731321

Glass cuvets (4 pcs)

HI 731325W

Caps for cuvets (4 pcs)

HI 93703-50

Cuvets cleaning solution (230 mL)

HI 740226

5 mL graduated syringe

HI 731340

200 

µ

L automatic pipette

HI 731350

Plastic tips for 200 

µ

L automatic pipette (25 pcs)

ACCESSORIES

Содержание HI 83748

Страница 1: ...Instruction Manual HI 83748 TARTARIC ACID ISM for wine analysis w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives MAN83748R3 04 06 w w w h a n n a i n s t c o m...

Страница 2: ...N ACCURATE MEASUREMENT 11 MEASUREMENT PROCEDURE 13 BATTERIES REPLACEMENT 16 ACCESSORIES 16 CE DECLARATION OF CONFORMITY 17 WARRANTY 17 HANNA LITERATURE 18 USER NOTES 19 Dear Customer Thank you for cho...

Страница 3: ...s Tissue for wiping cuvets Instruction manual Instrument Quality Certificate Rigid carrying case Note save all packing material until you are sure that the instrument works correctly Any defective ite...

Страница 4: ...n poly phenols and tartaric acid in red and proteins in white wine This explains why as pigment polymerization occurs the holding capacity of tartaric acid diminishes resulting in delayed casse The su...

Страница 5: ...ccurate The figure explains these definitions In a laboratory using a standard solution of 2 0 g L tartaric acid and a representative lot of reagent an operatorobtainedwithasingleinstrumentastandard d...

Страница 6: ...the substance as the other factors are known Photometric chemical analysis is based on the possibility to develop an absorbing compound from a specific chemical reaction between sample and reagents G...

Страница 7: ...zeroing cuvets are optically identical to provide the same measurement conditions Whenever possible use the same cuvet for both It is necessary that the surface of the cuvet is clean and not scratche...

Страница 8: ...READ key to perform measurement 8 Power Socket 12V to 20V DC 2 5 Watt FUNCTIONAL DESCRIPTION FRONT REAR INSTRUMENT DESCRIPTION 13 Turn the instrument on by pressing ON OFF MEASUREMENT PROCEDURE When t...

Страница 9: ...ng a zero measurement The light intensity is automatically re adjusted auto calibration features if necessary 12 Proper use of the dropper a to get good reproducible results tap the dropper on the tab...

Страница 10: ...ries and restart the meter Light low there is not enough light to perform a measurement Please check the preparation of the zero cuvet 11 The instructions listed below should be carefully followed dur...

Отзывы: