background image

4

5

Front Panel

Front Panel

Front Panel

Front Panel

Front Panel

FUNCTIONAL DESCRIPTION

FUNCTIONAL DESCRIPTION

FUNCTIONAL DESCRIPTION

FUNCTIONAL DESCRIPTION

FUNCTIONAL DESCRIPTION

1) Liquid Crystal Display (LCD).

2)

CAL

 key

to enter or exit/escape calibration mode.

3)

CFM

 key, to confirm different values.

4)

°C key and  °C keys, to manually increase/decrease tem-

perature or select pH buffer.

5)

RANGE 

key, to select measurement range (

HI 2211

 only).

6)

MEM

 key,

 

to store a value into memory.

7)

MR

 key, to recall the stored value.

8)

Secondary LCD.

9) Primary LCD.
10)

ON/OFF

 switch.

11) Power adapter socket.
12) BNC electrode connector.
13) Temperature probe socket.
14) Electrode reference socket.

The Hanna 

HI 2210 

and 

HI 2211 

are microprocessor-based pH and

temperature bench meters.

HI 2211

 can also be used for ion concentration (ISE) and Oxidation

Reduction Potential (ORP) in the mV range.
pH measurements are compensated for temperature effect manually or
automatically with the 

HI 7662

 temperature probe.

The instrument is equipped with a large easy-to-read LCD which shows
the pH (or mV) and temperature simultaneously, together with graphic
symbols.
The calibration process is guided step by step through clear indications on
the LCD. A stability indicator makes the calibration procedure error-free.

Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during shipping.
If there is any damage, notify your Dealer or the nearest Hanna
Customer Service Center.
Each instrument is supplied with:

HI 1131B

 Glass-body Combination pH Electrode

HI 7662

 Temperature Probe

HI 76404

 Electrode Holder

pH 4.01 & 7.01

 Buffer Solutions, 20 mL each

HI 7071S

 Electrolyte Solution

• 12VDC Power Adapter
• Instruction Manual

Note:

Save all packing material until you are sure that the
instrument functions correctly. All defective items must be
returned in the original packing with the supplied accessories.

PRELIMINARY EXAMINATION

PRELIMINARY EXAMINATION

PRELIMINARY EXAMINATION

PRELIMINARY EXAMINATION

PRELIMINARY EXAMINATION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

Hanna Instruments reserves the right to modify the design,

construction and appearance of its products without advance notice.

Rear Panel

Rear Panel

Rear Panel

Rear Panel

Rear Panel

Содержание HI 2211

Страница 1: ...1 Instruction Manual Microprocessor based pH mV C Bench Meters HI 2210 HI 2211 www hannainst com...

Страница 2: ...pping any instrument make sure it is properly packed for complete protection WARRANTY 3 PRELIMINARY EXAMINATION 4 GENERAL DESCRIPTION 4 FUNCTIONAL DESCRIPTION 5 SPECIFICATIONS 6 OPERATIONAL GUIDE 7 pH...

Страница 3: ...mV and temperature simultaneously together with graphic symbols The calibration process is guided step by step through clear indications on the LCD A stability indicator makes the calibration procedur...

Страница 4: ...probe approximately 4 cm 1 into the sample to be tested and stir gently Allow time for the electrode to stabilize The pH is displayed on the primary LCD and the temperature on the secondary LCD If the...

Страница 5: ...temperature probe into the sample as close as possible to the electrode and wait for a few seconds If the temperature of the sample is known manual temperature compensation can be performed by disconn...

Страница 6: ...in this situation CAL 2 BUF pH BUFFER pH p p p p pH CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION Calibrate the instrument often especially if high accuracy is required The inst...

Страница 7: ...down the CAL MEM keys then power on the instrument The CAL message will appear and the secondary LCD will show 0 0 C Immerse the temperature probe in the vessel with ice and water as near as possible...

Страница 8: ...9 3 0 4 4 8 6 9 9 6 1 1 9 2 9 9 0 4 4 0 1 4 0 4 4 8 6 8 9 6 7 0 9 8 8 9 5 4 3 1 1 5 0 4 3 8 6 8 9 6 4 0 9 5 8 9 0 5 2 2 1 6 0 4 3 8 6 8 9 6 1 0 9 2 8 9 5 5 1 3 1 8 0 4 4 8 6 8 9 6 9 9 8 9 7 9 0 6 0 4...

Страница 9: ...e Preparation Procedure on page 16 before taking measurements Note NEVER STORE THE ELECTRODE IN DISTILLED OR DEIONIZED WATER PERIODIC MAINTENANCE PERIODIC MAINTENANCE PERIODIC MAINTENANCE PERIODIC MAI...

Страница 10: ...s e g n a r e t y l o r t c e l e e h t k c e h C e l a r e n e g e h t d n a l e v e l e d o r t c e l e e h t f o e t a t s s w o h s y a l p s i d e h T d n a V m e h t n i e g n a r f o t u O e l...

Страница 11: ...n FDA approved bottle 4x50 mL for single junction electrodes HI 8072 1M KNO3 Electrolyte in FDA approved bottle 4x50 mL HI 8082 3 5M KCl Electrolyte in FDA approved bottle 4x50 mL Typical Electrode Li...

Страница 12: ...IA 0 29 S VERSION HI 1331 ORP PRETREATMENT SOLUTIONS HI 7091L Reducing Pretreatment Solution 460 mL bottle HI 7092L Oxidizing Pretreatment Solution 460 mL bottle pH ELECTRODES All electrodes part numb...

Страница 13: ...I 3230 S VERSION 120 mm 4 7 12 mm 0 5 HI 4430 S VERSION FC 100B Plastic body PVDF double junction refillable combination pH electrode Use general purpose for food industry FC 200B Plastic body PVDF op...

Страница 14: ...To avoid damage or burns do not perform any measurement in microwave ovens EXTENSION CABLE FOR SCREW TYPE ELECTRODES SCREW TO BNC ADAPTER HI 7855 1 Extension cable 1 m 3 3 long HI 7855 3 Extension cab...

Страница 15: ...2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739 3014 Fax 886 2 2739 2...

Отзывы: