3
IMPORTANT: READ PRIOR TO STARTING THIS EQUIPMENT
1.0 INSTALLATION
1.1 Location
A. For typical placement in a compressed air system, see
drawing.
B. Air compressor intake – Locate air compressor so that
contaminants potentially harmful to the dryer (e.g. ammo
-
nia) are not drawn into the air system.
C.
Free Air Flow - Allow a minimum of 36 inches (914 mm)
clearance for free air flow.
Service - To facilitate maintenance leave 36 inches
(914 mm) of clearance in front of dryer.
D. Standard units are designed to operate in ambients:
Air-cooled: 40 to 110°F (4 to 43°C).
Water-cooled: 40 to 130°F (4 to 54°C).
E. The installation of a flexible connection prior to the dryer is
recommended to prevent possible damage from vibration.
NOTE:
Outdoor installation – Standard units are designed for
in door installation. Contact manufacturer if installing outdoors.