6.6  Start-up

6.6.1  Controller Settings

Set or verify settings on Controller.  Detailed operational 

points are presented in section 6.5.

WARNING - Enclosure may have live electric parts. 

De-energize dryer before opening enclosure.

6.6.2  Initial Pressurization

SLOWLY

 pressurize dryer to full line pressure. (If the 

dryer was installed with inlet and outlet isolation valves, 

the inlet isolation valve should be slowly opened while 

the outlet isolation valve remains closed.)
During initial start-up, check the entire system for leaks. 

If  necessary,  de-pressurize  the  dryer  and  correct  any 

leaks.

6.6.2.1  Energy Management Sensor (if installed)

Open and adjust the sample exhaust valve until a very 

slight, continuous gas bleed is felt exhausting out of the 

sample cell.

6.6.2.2  Dew Point Sensor (if installed)

Ensure  that  the  supply  air  valve  is  open  (one  turn).  

Open and adjust the sample exhaust valve until a very 

slight, continuous gas bleed is felt exhausting out of the 

sample cell.

6.6.3  Energizing the Dryer

Energize the dryer controls.

NOTE:

 The switching failure alarm may be activated if the 

unit is energized before it is pressurized. To deactivate 

alarm, allow dryer to cycle to next step and press the 

reset button.

6.6.4  Bringing the Dryer On-line

Establish a normal flow through the dryer. Slowly open 

the  outlet  isolation  valve  if  present.  Close  any  dryer 

bypass valves.

6.7  Operational Check Points

6.7.1  Power to unit

Check  periodically  that  there  is  power  to  the  unit 

(indicating lights illuminated).

6.7.2  Alarms

Periodically check for flashing red alarm LED. 

6.7.3  Tower Status LEDs

Illuminated LEDs indicate which tower is on-line drying 

or off-line regenerating.

6.7.4  Tower Pressure Gauges

Periodically  check  tower  pressure  gauges  to  verify 

that the pressure gauge of the on-line tower reads line 

pressure and the pressure gauge of the off-line tower 

reads below 2 psig (0.14 kgf/ cm

2

).

NOTE:

 Read the off-line tower pressure gauge when the 

tower is purging (air exhausting from muffler).

6.7.5  Process Valves

Determine  if  air  control  valves  are  operating  and 

sequencing correctly.

6.7.5.1  Valves – Models 500 and 600

Inlet switching valves are normally open, pneumatically 

piston-actuated, Y-angle poppet valves. A yellow indicator 

can be seen through a clear window at the top of the ac-

tuator housing when the valve is in the open position.
Purge exhaust valves are normally closed, pneumati-

cally piston-actuated, Y-angle poppet valves. A yellow 

indicator can be seen through a clear window at the top 

of the actuator housing when the valve is in the open 

position.
12 volt DC, normally-closed, 3-way pilot solenoid valves 

are wired to the controller and are used to direct pilot air 

to the actuators of the inlet switching and purge/repres-

surization valves.
Dryers are equipped with a safety relief valve that has 

been sized to provide overpressure protection due to a 

fire for both desiccant towers.

6.7.5.2  Valves – Models 750 through 4300

Inlet switching valves are resilient seated butterfly valves 

with double acting pneumatic rack and pinion actuators.  

A yellow arrow indicator located on the top of the actuator 

output shaft points to valve position indicator icons. Pilot 

air is directed to actuator ports to open both inlet valves 

upon loss of power.

(Model 750 only)

 Purge exhaust valves are normally 

closed, pneumatically piston-actuated, Y-angle poppet 

valves. A yellow indicator can be seen through a clear 

window at the top of the actuator housing when the valve 

is in the open position.

(Models 900 through 4300)

 Purge exhaust valves are 

resilient seated butterfly valves with spring return, fail 

closed, pneumatic rack and pinion actuators.  A yellow 

arrow indicator located on the top of the actuator output 

shaft points to valve position indicator icons. Pilot air is 

directed  to  actuator  ports  to  close  both  purge/repres-

surization valves upon loss of power.
12 volt DC, single solenoid, 4-way pilot valves are wired 

to the controller and are used to direct pilot air to the 

actuators of the inlet switching and purge/repressuriza-

tion valves.
Two  mainline  outlet  and  two  purge  line  check  valves 

are installed in the upper piping to control the flow of 

outlet and purge air.  Check valve sticking will result in 

excessive air discharge through a muffler. Excessive air 

discharge through the muffler can be associated with a 

leaking outlet check valve on the same side or a purge 

check valve of the opposite side tower.

Содержание HBP Series

Страница 1: ...36 Electrical Schematic 460VAC 3 phase 38 Electrical Schematic 575VAC 3 phase 39 Electrical Schematic 380VAC 3 phase 40 Electrical Schematic 415VAC 3 phase 41 Electrical Data Fusing Wire Sizing 42 WAR...

Страница 2: ...R WARNING and CAUTION are used to indicate hazard seriousness levels as follows DANGER Immediate hazard which will result in severe injury or death WARNING Hazard or unsafe practice which could result...

Страница 3: ...ryer in order to protect the desiccant bed from liquid and solid contamination Use an Air Line Filter in systems sup plied by a non lubricated oil free air compressor In systems supplied by a lubricat...

Страница 4: ...lectrical enclosure for a remote alarm The contact ratings are shown on the electrical drawing Compressor Aftercooler Separator Receiver Prefilters Afterfilters Receiver Desiccant Dryer Figure 1 Typic...

Страница 5: ...ty and purpose of the desic cant Layer 1 must be installed rst at the bottom of the vessel followed by layer number 2 etc until the complete charge of desiccant has been installed 4 Utilizing an appro...

Страница 6: ...E MAX F G C D B A MAX H K N MAX P L S GAS INLET M FACE OF CUSTOMER WET GAS INLET CONNECTION FACE OF CUSTOMER DRY GAS OUTLET CONNECTION R SLOT TYP 4 PLACES TOP VIEW SIDE VIEW RIGHT CHAMBER REMOVED FOR...

Страница 7: ...NPT 3 FLANGE 3 FLANGE 3 FLANGE 3 FLANGE 3 FLANGE 4 FLANGE 4 FLANGE 4 FLANGE 4 FLANGE 6 FLANGE 6 FLANGE T 2 NPT 2 NPT 3 FLANGE 3 FLANGE 3 FLANGE 3 FLANGE 3 FLANGE 4 FLANGE 4 FLANGE 4 FLANGE 6 FLANGE 6...

Страница 8: ...ge mounted on the gauge panel of the dryer indicates purge air pressure 5 4 Energy Management System The optional Energy Management System EMS automatically adjusts dryer operation to compensate for c...

Страница 9: ...DRAIN PORT TOWER INSULATION OPTIONAL CONTROL ENCLOSURE HIGH TENSION ENCLOSURE RIGHT TOWER PRESSURE GAUGE PURGE PRESSURE GAUGE REPRESS VALVE HEATER TEMP THERMOCOUPLE CENTER END IN PIPE OPPOSITE SIDE H...

Страница 10: ...ER DEPRESS VALVE ASME RELIEF VALVE REPRESS VALVE TOP VIEW FRONT VIEW PURGE HEATER WITH INSULATION PURGE SUCTION FILTER SILENCER PURGE BLOWER AND MOTOR REAR VIEW LEFT TOWER INLET VALVE ASME CODE TAG LE...

Страница 11: ...DEPRESS VALVE DESICCANT DRAIN PORT TOWER INSULATION OPTIONAL HIGH TENSION ENCLOSURE CONTROL ENCLOSURE RIGHT TOWER PRESSURE GAUGE PURGE PRESSURE GAUGE REPRESS VALVE PURGE BLOWER AND MOTOR PURGE BLOWER...

Страница 12: ...slowly depressurized Air exits through exhaust muf er M2 After the right tower has depressurized the Right Purge Valve V4 is opened and the Blower M and Heater H1 are energized The heated air ows thro...

Страница 13: ...LEFT TOWER SET 45 PSIG M RTD 3 SET 650 F 1TC SET 370 F V5 2PS SET 176 F 4PS SET 5 PSIG REGEN SET 45 PSIG SET AT 100 PSIG RIGHT TOWER V8 V12 V13 SOL E V7 V11 RV1 SET 165 PSIG DEWPOINTER OPTION DPA SOLE...

Страница 14: ...d because the repressurization step will occur before the bed temperature can fall to 150 F Note In Energy Management or Dew Point Control as the drying time extends beyond 4 hours additional cooling...

Страница 15: ...is installed in the OFF position if Switching Failure is disabled 6 JP6 Not Used NOTE Jumpers JP7 and JP8 are used by the factory during nal inspection to download language text and to enable factory...

Страница 16: ...for the Heated Desiccant Dryer Control a Program Mode b Setup Mode c Alarm Service Mode d Display Mode e Test Mode 2 Each Mode is described below 6 5 4 Program Mode 1 Press and hold and for 3 seconds...

Страница 17: ...Point Demand Control Displayed only when JP3 on DPNT CNTL SETPT XX C XXX F 1 Press to increment the setting to the desired value a Standard set point is 30 C 22 F b The allowable range of values is fr...

Страница 18: ...m Vapor Pressure Set Point screen 9 4 When nished press to acknowledge the se lection and scroll to the switchover delay set point screen a Factory set point is 60 MIN b The allowable range of values...

Страница 19: ...ing the drying cycle b Left or Right tower regenerating high pressure i Regenerating tower pressure switch is closed while purge valve is open after an initial time delay c Left or Right tower regener...

Страница 20: ...UNDER RANGE ALARM RIGHT TWR DEW POINT OVER RANGE ALARM LEFT TOWER TEMP UNDER RANGE ALARM LEFT TOWER TEMP OVER RANGE ALARM RIGHT TWR TEMP OVER RANGE ALARM RIGHT TWR TEMP UNDER RANGE ALARM RIGHT TWR DR...

Страница 21: ...rogram Mode b Humidity Sensor i Under range RH 15 ii Over range RH 115 c RTD i Over range Temperature above 448 F 231 C ii Under range Temperature below 20 F 28 C d On alarm condition i Local alarm is...

Страница 22: ...upplied to the controller whether the controller is switched on or off When a service time interval expires see also 14 d below the controller operates as follows a The service LED blinks and the appr...

Страница 23: ...e reminder lters HOURS TO SERVICE FILTERS XXXX Service reminder desiccant HOURS TO SERVICE DESICCANT XXXX Service reminder valves HOURS TO SERVICE VALVES XXXX Outlet Dew Point Displayed only if JP3 is...

Страница 24: ...ying Drying Drying Drying 1PS Closed Closed Closed Closed Closed Closed Closed then Open Open Open Open then Closed 2PS Closed Closed then Open Open Open Open then Closed Closed Closed Closed Closed C...

Страница 25: ...pressurized Exception If switching failure is disabled then pressure condition is ignored Screen 6 Step 6 TEST6 RT DRYING RT XX C XXX F Screen 7 Step 7 TEST7 DEPR LT LT XX C XXX F Note Sequence step...

Страница 26: ...d 600 Inlet switching valves are normally open pneumatically piston actuated Y angle poppet valves Ayellow indicator can be seen through a clear window at the top of the ac tuator housing when the val...

Страница 27: ...ization valve closes 6 9 1 2 On restoration of power 1 If power is lost when the off line tower is in either the HEAT or COOL step the off line tower will be either partially or fully repressurized On...

Страница 28: ...ASCII representation of the energy savings x Reserved for future use always 1 for now ETX end of text character OxO3 CR carriage return LF line feed JUMPERS The programming jumpers are as follows 0 o...

Страница 29: ...Layer 1 must be installed rst at the bottom of the vessel followed by layer number 2 etc until the complete charge of desiccant has been installed e Utilizing an appropriate sized funnel ll each desi...

Страница 30: ...Replacement may be required sooner if pressure drop across cartridge prevents the Dew Point Analyzer from operating properly Warning The Dew Point Analyzer lter housing is a pressure containing device...

Страница 31: ...k Valve leak ing 1 Check compressor supplying dryer 2 Check equipment downstream of dryer 3 Check pressure switch operation using tower pressure gauge for comparison Replace switch if defective 4a Che...

Страница 32: ...3 Regenerating tower Depressurization Valve failed to close 4 Repressurization valve V11 failed to open 5 Repressurization ori ces are blocked 1 Check pressure switch operation using tower pressure ga...

Страница 33: ...ins Repair or replace as necessary Useful life of desiccant has been exceeded Heater Over Temperature Alarm 1 Insuf cient purge gas ow 2 Temperature sensor failure 1 Check for purge blockage temperatu...

Страница 34: ...SOL C 2 1 3 LEFT TOWER SET 45 PSIG M RTD 3 SET 650 F 1TC SET 370 F V5 2PS SET 176 F 4PS SET 5 PSIG 18 REGEN 9 SET 45 PSIG SET AT 100 PSIG RIGHT TOWER 12 11 8 7 V8 26 V12 V13 SOL E V7 V11 SET 165 PSIG...

Страница 35: ...43 ENERGY MANAGEMENT SENSOR RTD4 HS1 DEWPOINTER OPTION 44 DEWPOINT ANALYZER 44A DEWPOINT ANALYZER FILTER INSULATION OPTION 54 CHAMBER INSULATION LEFT CHAMBER DRYING RIGHT CHAMBER REGEN CLOSED NO 3 WA...

Страница 36: ...TD 3 SET 650 F 1TC SET 370 F V5 V6 2PS REGEN SET 176 F 4PS SET 5 PSIG 18 9 RIGHT TOWER SET 45 PSIG SET AT 100 PSIG 12 11 8 7 26 V12 V13 SOL E V11 V7 V8 SET 165 PSIG DEWPOINTER OPTION DPA 15 3 22 14 13...

Страница 37: ...AGEMENT SENSOR RTD4 HS1 DEWPOINTER OPTION 44 DEWPOINT ANALYZER 44A DEWPOINT ANALYZER FILTER INSULATION OPTION 54 CHAMBER INSULATION FAILS IN POSITION LEFT CHAMBER DRYING RIGHT CHAMBER REGEN CLOSED NO...

Страница 38: ...ENERGY MGMT OPTION RTD4 1HTR 102 101 102 102 102 1CR 102 101 101 101 109 111 101 107 SOLENOID C 21 LEFT CHAMBER PURGE EXHAUST HEAT ENABLE C NO 101 102 20 21 80 81 70 72 21 10 11 84 85 86 87 88 89 32 3...

Страница 39: ...2HC2 2HC3 507 508 509 4 20MA OUT ENERGY MGMT OPTION RTD4 2HTR 102 101 102 102 102 1CR 102 101 101 101 109 111 101 107 SOLENOID C 21 LEFT CHAMBER DEPRESS LEFT CHAMBER PURGE EXHAUST HEAT ENABLE C NO 101...

Страница 40: ...ON RTD4 1HTR 102 101 102 102 102 1CR 102 101 101 101 109 111 101 107 SOLENOID C 21 LEFT CHAMBER DEPRESS LEFT CHAMBER PURGE EXHAUST HEAT ENABLE C NO 101 102 20 21 80 81 70 72 21 10 11 84 85 86 87 88 89...

Страница 41: ...101 102 102 102 1CR 102 101 101 101 109 111 101 107 SOLENOID C 21 LEFT CHAMBER DEPRESS LEFT CHAMBER PURGE EXHAUST HEAT ENABLE C NO 101 102 20 21 80 81 70 72 21 10 11 84 85 86 87 88 89 32 33 34 35 50...

Страница 42: ...AWG 4300 HEATER 2 35 KW 2 35 1 2 40 AMPS 2 8 AWG MOTOR 7 5 HP 9 15 AMPS 12 AWG Models 3200 3600 and 4300 use a two stage heater circuit with two contactors six fuses and six wires Electrical Service...

Страница 43: ...43...

Страница 44: ...arranty and any resulting charge or subsequent claim will not be paid THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WRITTEN ORAL OR STATUTORY AND IS EXPRESSED IN LIEU OF THE...

Отзывы: