INSTALLATION AND ADJUSTMENT
9
§3 Installation and Adjustment
§3.1 Parameters
Model
Parameters
HSG130(115V)
Input Voltage
(
V
)
1~110/115
±
10%
Input Current
(
A
)
43 (max.)
Input Power
(
KW
)
3.5
Welding
Current
(
A
)
35~140
No-load
Voltage
(
V
)
57
Duty cycle
(
4
0
℃)
20%130A
100%70A
Diameter(mm)
Fe
:
0.6/0.8 SS: 0.6/0.8 Flux-Cored
:
0.6/0.8/0.9
Protection
class
IP23
Insulation
class
H
Dimensions
(
mm
)
443*191*320
Weight
(
Kg
)
8.9
Note: The above parameters are subject to change with the improvement of
machines.
§3.2 Duty cycle and Over-temp
The CSA/UL rated duty cycle is defined as the proportion of the time that a machine can work
continuously over a 10 minute cycle when set at 100% of rated output welding current in 40C
(104F) ambient environment.
When the transformer reaches an over-heat condition, the heat sensor inside it will open and
will output an instruction to circuit board to cut AC relay and the output welding current while
illuminating the over-heat pilot lamp in the front panel. At this time, all welding operations should
cease for 15 minutes allowing the cooling fan to reduce the temperature. The unit will auto-reset
when correct temperature has been achieved and pilot light will go out. If the machine reached
the over-temp capacity again, the welding output current or the arc cycle should be reduced.
Содержание HSG130
Страница 10: ...OVERVIEW 8 2 4Principles of welding...
Страница 17: ...THANK YOU FOR USING OUR PRODUCTS 15 5 3 Replacement Exploded Parts Drawing...
Страница 18: ...THANK YOU FOR USING OUR PRODUCTS 16 5 4 MIG Gun Exploded Parts...
Страница 19: ...THANK YOU FOR USING OUR PRODUCTS 17 5 5 Electrical Schematic Drawing HSG130 115VAC input...