Quick Reference Guide Handicare 2000
37
The power
ed footr
est
does not operate
No 24 V = between
M14 and gr
ound
24 V= between
M14 and gr
ound
The operation switch
S26 or S28 is faulty
Main switch S21 switched of
f
The emer
gency switch S34
is faulty
The boar
d
P2 is faulty
The main switch S21 is faulty
The keyswitch S23
is faulty
Ther
e is a br
eak in the curr
ent between
U15 or U17 and U7
Br
oken fuse 25 A
Ther
e is a br
eak in the curr
ent between
M8-9,U8-2,U10-2, U11-2, U11-1, U10-1
and U18-3
Ther
e is a br
eak in the curr
ent between
U7 and M21
Br
eak in curr
ent between
M2, M3 and M14
Ther
e is a br
eak in the curr
ent between
the power
ed footr
est motor and M15
Flat batteries
The power
ed footr
est motor
is faulty
Ther
e is a br
eak
in the gr
ound connection and M16