Quick Reference Guide Handicare 2000
29
Lift does not move in downwar
ds dir
ection (right)
or upwar
ds dir
ection (left)
Code: “4”
Connect the molex testing link
The rail is on the leftside of the
stairs. The lift will not move up.
The voltage between M7-5 and
gr
ound is 3,5 V
Main boar
d P1 is faulty
The rail is on the righttside of the
stairs. The lift will not move down.
The voltage between M7-5 and
gr
ound is 3,5 V
Main boar
d P1 is faulty
The
rail
is
on
the
leftside
of
the
stairs.
The lift will not move up
The voltage between
M7-5 and gr
ound is not 3,5 V
Ther
e is an obstacle blocking the
upperside of the pack or
the upperside of the footr
est
Ther
e is a br
eak in the curr
ent in the
line : M7-5, U9-4, U9-5, M7-7
The footr
estswitch S8
is faulty
The rail is on the right side of the
stairs. The lift will not move down.
The voltage between
M7-5 and gr
ound is not 3,5V
Ther
e is an obstacle blocking
the downside of the pack or the
downside of the footr
est
Ther
e is a br
eak in the curr
ent in
the line: M7-5, U9-2, U9-1, U9-4,
U9-5 and M7-7
The fr
ont chassis edge switch
S11 or S12 is faulty
The footr
est switch S8,S9
is faulty