AI-118 operation manual
issue 1 19.10.07 display version 07 . plc controller version 07
P.36 of 50
Fixed Length Mode
Press #6 fixed length mode icon at the “main function” page (figure 14) will turn to the
page of “fixed length mode” page.
1
3
4
5
6
7
2
Figure 24 Fixed Length Mode Page
1. Fixed length mode on/off button. When the fixed length mode is on, the mode
with the open state will be completed in order; when the fixed length mode is off,
the setting of the fixed length mode will not work.
2. A
red dot indicates that the machine is performing a fixed length operation of
mode 1, and which mode the red dot follows indicates which mode is in progress.
3. Go back to the previous page; the previous page is the “main function” page.
4. Press to turn on/off the corresponding fixed length mode.
5. Press to preset the additional strokes of corresponding fixed length mode.
6. Press to preset the times of corresponding fixed length mode
。
7. Display the number of completions of corresponding fixed length mode. When the
number is equal to the number of set times, it will turn to zero.