3 - 41
padPromptSignature
Displays a signature capture prompt on the pad. You can set the compressed capture
mode using the
(see page 3-51) command. The illustration depicts
the layout of the signature prompt. The data is returned in a special Transaction Team
signature data packet. This packets needs to be post-processed to extract the signature
data from the buffer. Please contact Hand Held Products for more information on
extracting the signature data returned from this command.
Syntax
BOOL padPromptSignature(
char *Title,
WORD MaxPoints,
char *SigData,
WORD SigBufSize,
WORD *SigDataSize
)
Parameter
Description
Title
Specifies the title of the displayed prompt pad. Its a pointer to a null terminated
character string.
MaxPoints
Maximum signature capture points (default = 1024)
SigData
A pointer to the buffer to hold the signature data
SigBufSize
Specifies the maximum size of the signature data buffer
SigDataSize
Returns a 16-bit value representing the size of the captured signature data
Returns
Returns TRUE upon success, FALSE otherwise.
See Also
padPromptHexNumber, padPromptNum, padPromptNumber, padPromptReset, padPromptString,
padPromptTimeout
padPromptString
Displays an alphanumeric keypad and returns the entered alphanumeric data. This
command prompts the user to enter alphanumeric data. The prompt includes
“ENTER”, “CLEAR”, ”C”, “UNDO”, and “CANCEL” buttons. “ENTER” accepts the
alphanumeric entry. “CLEAR” and “C” both clear the alphanumeric entry. “UNDO”
removes the last character entered. “CANCEL” exits the prompt. The alphanumeric
data can have up to 17 characters. The result is returned as a text string containing
the characters entered. The illustration depicts the string input keypad.
Syntax
BOOL padPromptString(
char *Title,
WORD MaxDigits,
char *Result
)
Parameter
Description
Title
Specifies the title of the displayed alphanumeric entry pad. Its a pointer to a null
terminated character string.
MaxDigits
Maximum alphanumeric characters to be displayed
Result
Returns a variable length text string containing the alphanumeric data entered
Returns
Returns TRUE upon success, FALSE otherwise.