3 - 62
Syntax
BOOL padSetType (
int Type
)
Parameter
Description
Type
Used to specify the type of Transaction Team pad
Returns
Returns TRUE if the type of pad specified is valid and FALSE otherwise.
See Also
padOn, padSetPort, padSetPortAddr, padSetPortIrq
padSoundBell
This command allows you to play various different types of preset sounds stored in the Transaction Team 3100 Series
devices. The parameter
BellType
has the following valid decimal setting (hexadecimal values are in parenthesis):
0
(0x00) - cancels any sound being played
1
(0x01) - plays the standard “bell” sound
16
(0x10) - plays an “alarm” sound
20
(0x14) - plays a “success” sound
24
(0x18) - plays a “fail” sound
Syntax
BOOL padSoundBell(
WORD BellType
)
Parameter
Description
BellType
Type of sound the device makes
Returns
Returns TRUE upon success, FALSE otherwise.
See Also
padSoundTone, padSoundSetFreq, padSoundEnable
padSoundEnable
This command enables or disables the speaker on a Transaction Team 3100 Series or compatible device.
Syntax
BOOL padSoundEnable(
BYTE Enable
)
Parameter
Description
Enable
Zero to disable; Non-zero to enable
Returns
Returns TRUE upon success, FALSE otherwise.
See Also
padSoundTone, padSoundBell, padSoundSetFreq