HAMPTON BAY Wood Insert HI200 Скачать руководство пользователя страница 23

HI200 Hampton Wood Cast Insert

23

WARRANTY

Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects 
each unit thoroughly before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to 
the  original purchaser of a Hampton Product. This warranty is not transferable.

The Warranty:  

Limited Lifetime

H200 / H300: Firebox castings on all Hampton Wood burning Appliances are covered against manufacturer defects for a period of three (3) years parts and 
subsidized labour* and a further two (2) years, parts only. Stainless steel baffl es are covered against manufacturer defects for a period of three (3) years 
parts and subsidized labour* and parts only thereafter.

HI300: Steel fi reboxes to be free from defects in materials and workmanship, also covered are vermiculite baffl es and air tubes (against warpage) against 
manufacturer's defects for a period of 3 years parts and subsidized labor and parts only thereafter. 

External casting, not directly in contact with the fi re, such as hobs, sides, side shelves, ash lips, legs, fronts, fi re doors and surrounds are covered against 
cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for three (3) years and parts only thereafter from date of pur-
chase.

Blowers and electrical are covered against manufacturer defect for two years parts and one year subsidized labour* from date of purchase. Replacement 
blowers are considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of 
three (3) months coverage from date of replacement.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a 
receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer 
within three days of installation. Reported damage after this time will be subject to rejection.

Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distribu-
tor or agent provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI 
and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Hampton product. FPI will not be liable for results or costs of 
workmanship from unauthorized service persons or dealers. 

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint (charcoal units),  porcelain (including pinholes, scratches and minor shade mismatch), 
door or glass gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit 
once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty 
policy.

Refractory liners (fi rebrick), gaskets, door handles, paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper instal-
lation, negligence or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative 
air pressure caused by mechanical systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

* Subsidy according to job scale as predetermined by FPI.

Содержание Wood Insert HI200

Страница 1: ...da V4G 1H4 918 739b HI200 Wood Cast Insert 07 19 11 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Ple...

Страница 2: ...MPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact loc...

Страница 3: ...ace 11 Installation Into a Masonry Fireplace 11 Fan Cast Faceplate Installation 12 Brick Flue Baffle Secondary Air Tube Installation 14 Firebrick Assembly 14 Draft Control 14 First Fire 15 Fan Operati...

Страница 4: ...PROTECTION AGENCY CERTIFIED TO COMPLY WITH JULY 1990 PARTICULATE EMISSION STANDARDS JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC 2011 2012 2013 Duplicate Serial MADE IN CANADA 339 DATE OF MANUFAC...

Страница 5: ...nsert use these dimensions to en sure appropriate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STA...

Страница 6: ...9 9 16 4 9 16 15 1 16 6 3 8 14 1 8 25 NOTE BeforeassemblingyourInsert use these dimensions to en sure appropriate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section...

Страница 7: ...lling and using your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department Y...

Страница 8: ...ial with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a K factor of 0 29 Step a Use formula above to convert specification to R...

Страница 9: ...daptor using 3 screws 1 in the front and 1 each on the left and right side Flex Liner Diagram 1 Your insert is very heavy and will require two or three people to move it into position 1 Remove the Doo...

Страница 10: ...wn in diagram 4 While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged See diagram 5 Pull Rod 10 Ensure that the unit is still level 11 To complete the i...

Страница 11: ...spection authority Three methods of flue connection are acceptable in most areas these include 1 Positive flue connection where a large blocking plate and a short connector pipe is used 2 Direct flue...

Страница 12: ...unting Bracket Mounting Bracket Gasket Gasket 2 Slide the unit into position leaving partially out to allow for installation of the left and right side surrounds 3 Install the left and right side surr...

Страница 13: ...g temperature or at least 30 minutes after starting fire 8 Surround adjustments can be made up or down loosen 4 bolts shown on face of unit Diagram 7 and adjust Surround can also be adjusted left or r...

Страница 14: ...talltheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side asfaraspossibleandthenbringitback i...

Страница 15: ...nced during the heating up process Thesenoiseswillbeminimalwhenyourunit reaches temperature 12 Before opening your door to reload open draftfullyforapproximately10to15seconds until fire has been re es...

Страница 16: ...of by burial in soil or otherwise locally dispersed they should be retained in the closedcontaineruntilallcindershavethoroughly cooled Other waste should not be placed in the ash container SOME SAFETY...

Страница 17: ...ure that the glass gasketing will properly seal your unit 5 Re install the glass retainer Ensure that it rests on the gasket and not the glass 6 Secure glass retainer using the 4 screws Do not wrench...

Страница 18: ...justment as the door gasket material com presses over time Removal of spacers will allow the latch to be moved closer to the door frame causing a tighter seal 1 Remove the Latch Assembly from the unit...

Страница 19: ...ch by undoing the inner 2 bolts Adjust to desired location and retighten the 2 bolts make sure the door catch closes freely and makes a good seal Do a paper test to confirm seal Latch Assembly Latch A...

Страница 20: ...Density Door Gasket Kit 20 210 911 Fan Blower Assembly Metallic Black 210 915 Fan Blower Assembly Timberline Brown 910 157 P Blower Fan Motor 910 684 Power Cord 120 Volts 910 142 Fan Thermodisc 910 14...

Страница 21: ...ast Insert 21 CAST FACEPLATE Part Description 210 921 Metallic Black Faceplate 210 925 Timberline Brown Faceplate 1 Top Surround 2 Left Side Surround 3 Right Side Faceplate Not available as a replacem...

Страница 22: ...t Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Part...

Страница 23: ...days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FP...

Страница 24: ...__________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No ___________________________________...