BRICK FLUE BAFFLE &
SECONDARY AIR TUBE

INSTALLATION

The fl ue baffl e system located in the upper area 
of the fi rebox is removable to make cleaning 
your chimney system easier.  The brick baffl es 
must be installed prior to your fi rst  fi re. 

 Smoke 

spillage and draft problems may occur if  the 
baffl es are improperly positioned. 

 Check the 

position of the brick baffl es on a regular basis as 
they can be dislodged if too much fuel is forced 
into the fi rebox. 

FIREBRICK ASSEMBLY

Firebrick is included to extend the life of your 
insert and radiate heat more evenly.  Check to 
see that all fi rebricks are in their correct posi-
tions and have not become misaligned during 
shipping.  

Side View

Front View

Front View

DRAFT CONTROL

Before establishing your fi rst fi re, it is important 
that you fully understand the operation of draft 
control. The draft control rod is on the left side 
of the Insert and it controls the intensity of the 
fi re by increasing or decreasing the amount 
of air allowed into the fi rebox. To increase the 
draft, slide the rod to the left and to decrease 
the draft, slide the rod to the right.

1)

  If the two air tubes are installed continue 

on to Step 2), if not, follow the instructions 
below. Install the air tube into the holes in the 
side channels. The notch goes on the right 
hand side with the air holes facing toward 
the door. Slide the tube into the left hand 
side, as far as possible and then bring it back 
into the hole on the right hand side until it 
locks into position. If the tube will not slide 
in easily simply use a pair of vise grips or 
pliers and tap it into place with a hammer. A 
tighter fi t will ensure the tube will not move 
when the unit is burning. 

2)

  Slide the left baffl e brick over the front air 

tube and then slide it back over the rear air 
tube.

3) 

Tilt the left baffl e brick up on top of the side 
channel and it will leave enough room to 
position the right baffl e brick in the same 
manner as Step 1) above. Then reposition 
the left baffl e brick fl at on the air tube. 

4) Important: push both baffl e bricks so 

they are tight against the side walls and 
to the back.

Note:  When getting the chimney cleaned, 

remove the baffl e bricks for access 
to the fl ue, then replace them when 
cleaning is completed.

As well as a primary and glass wash air system, 
the unit has a full secondary draft system that 
allows air to the induction ports at the top of the 
fi rebox, just below the fl ue baffl e.

WARNING:  To build a fi re in ignorance or to 
disregard the informa tion contained in this 
section can cause serious permanent dam-
age to the unit and void your warranty.

INSTALLATION

Slide Left to

Increase Draft

Slide Right to

Decrease Draft

Содержание Wood Insert HI200

Страница 1: ...da V4G 1H4 918 739b HI200 Wood Cast Insert 07 19 11 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Ple...

Страница 2: ...MPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact loc...

Страница 3: ...ace 11 Installation Into a Masonry Fireplace 11 Fan Cast Faceplate Installation 12 Brick Flue Baffle Secondary Air Tube Installation 14 Firebrick Assembly 14 Draft Control 14 First Fire 15 Fan Operati...

Страница 4: ...PROTECTION AGENCY CERTIFIED TO COMPLY WITH JULY 1990 PARTICULATE EMISSION STANDARDS JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC 2011 2012 2013 Duplicate Serial MADE IN CANADA 339 DATE OF MANUFAC...

Страница 5: ...nsert use these dimensions to en sure appropriate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STA...

Страница 6: ...9 9 16 4 9 16 15 1 16 6 3 8 14 1 8 25 NOTE BeforeassemblingyourInsert use these dimensions to en sure appropriate clearances will be met refer to Masonry and Factory Built Fireplace Clearances section...

Страница 7: ...lling and using your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department Y...

Страница 8: ...ial with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a K factor of 0 29 Step a Use formula above to convert specification to R...

Страница 9: ...daptor using 3 screws 1 in the front and 1 each on the left and right side Flex Liner Diagram 1 Your insert is very heavy and will require two or three people to move it into position 1 Remove the Doo...

Страница 10: ...wn in diagram 4 While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged See diagram 5 Pull Rod 10 Ensure that the unit is still level 11 To complete the i...

Страница 11: ...spection authority Three methods of flue connection are acceptable in most areas these include 1 Positive flue connection where a large blocking plate and a short connector pipe is used 2 Direct flue...

Страница 12: ...unting Bracket Mounting Bracket Gasket Gasket 2 Slide the unit into position leaving partially out to allow for installation of the left and right side surrounds 3 Install the left and right side surr...

Страница 13: ...g temperature or at least 30 minutes after starting fire 8 Surround adjustments can be made up or down loosen 4 bolts shown on face of unit Diagram 7 and adjust Surround can also be adjusted left or r...

Страница 14: ...talltheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side asfaraspossibleandthenbringitback i...

Страница 15: ...nced during the heating up process Thesenoiseswillbeminimalwhenyourunit reaches temperature 12 Before opening your door to reload open draftfullyforapproximately10to15seconds until fire has been re es...

Страница 16: ...of by burial in soil or otherwise locally dispersed they should be retained in the closedcontaineruntilallcindershavethoroughly cooled Other waste should not be placed in the ash container SOME SAFETY...

Страница 17: ...ure that the glass gasketing will properly seal your unit 5 Re install the glass retainer Ensure that it rests on the gasket and not the glass 6 Secure glass retainer using the 4 screws Do not wrench...

Страница 18: ...justment as the door gasket material com presses over time Removal of spacers will allow the latch to be moved closer to the door frame causing a tighter seal 1 Remove the Latch Assembly from the unit...

Страница 19: ...ch by undoing the inner 2 bolts Adjust to desired location and retighten the 2 bolts make sure the door catch closes freely and makes a good seal Do a paper test to confirm seal Latch Assembly Latch A...

Страница 20: ...Density Door Gasket Kit 20 210 911 Fan Blower Assembly Metallic Black 210 915 Fan Blower Assembly Timberline Brown 910 157 P Blower Fan Motor 910 684 Power Cord 120 Volts 910 142 Fan Thermodisc 910 14...

Страница 21: ...ast Insert 21 CAST FACEPLATE Part Description 210 921 Metallic Black Faceplate 210 925 Timberline Brown Faceplate 1 Top Surround 2 Left Side Surround 3 Right Side Faceplate Not available as a replacem...

Страница 22: ...t Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Part...

Страница 23: ...days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FP...

Страница 24: ...__________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No ___________________________________...

Отзывы: