HAMPTON BAY H35-LP1 Скачать руководство пользователя страница 8

8

Hampton

®

 H35 Direct Vent Freestanding Gas Stove

OPTIONAL FAN INSTALLATION

Diagram 1

Diagram 2

LOCATING YOUR

 GAS STOVE

 
When selecting a location for your stove, ensure 
that the clearances listed above are met as well 
as ensuring that there is adequate accessibility 
for servicing and proper operation.

MANUFACTURED 

MOBILE HOME 

ADDITIONAL 

REQUIREMENTS

1)

  Ensure that structural members are not cut 

or weakened during installation.

2)

  Ensure proper grounding using the #8 

ground lug provided.

3)

  Appliance must be anchored to the fl oor 

with the supplied anchoring methods. 

COMBUSTION AND 

VENTILATION AIR

The combustion air from this appliance is drawn 
from outside the building through the outer fl ue. 

Extra provision for combustion air inside the 
room is not required.

A) Cross 

Corner 

B) Room 

Divider

C) Island 

 

D) Flat 

on 

Wall

E) 

Flat on Wall Corner 

F) 

Flush with Wall/Alcove

For Vent Termination requirements, see the 
"Exterior Vent Terminal Locations" section.

Fan Kit Contains:

Qty. Description

1  

 

Fan Speed Controller with nut, and  

 knob.

1  

 

Fan Assembly c/w green wire   

 attached 

1  

 Power 

cord 

 

1  

 

Plastic locking grommet

 

1)

  Remove the Top Control Panel Assembly 

by removing the three screws. Diagram 1.

2)

  Remove the nylon hole plug from the control 

panel.

3)

  Install the fan speed controller onto the 

control panel and secure with nut. Connect 
remaining wire harness wires to speed 
control. 

NOTE:

 Speed control wires must 

be in the down position when control panel 
is in place.

4)

  Push black knob onto speed control.

5)

  Remove the rear access panel on the back 

of the stove by removing the 6 screws. Install 
the fan onto pins as per Diagram 2.

 

 

NOTE: Do NOT damage, cut or remove 
the 3" aluminum air intake pipes.

 

Hint for pushing fan down onto pins - rub a 
bit of dish soap on the pins so the grommets 
will slide down more easily. Check to make 
sure the fan is seated properly on the pins 
- try to move the fan back and forth.

 

6)

  Push power cord through hole in the rear 

panel 14" - 16" and tie a loose knot in the 
cord on the inside to prevent the power cord 
from being pulled out. Diagram 2.

7)

   Install locking grommet to power cord and 

push through hole in the rear panel and give 
a 1/4 turn to secure.

NOTE:  When running wires, keep them clear 

of valve assembly and tubing to avoid 
tangling of wires and valve.

NOTE: Be careful not to cut wires when pass-

ing through holes in the fi rebox.

8)

  Run green ground wire from fan and connect 

to grounding lug.

9)

  Connect green power cord ground wire to 

grounding lug. 

10)

 Run the neutral black wire from power cord 

and connect to fan motor.

11)

  Run the live black wire from power cord and 

connect to  speed control wire.

12)

 Connect the white wire of the wire harness 

to the fan terminal.

 

NOTE: Pull excess wire  next to fan to 
avoid excessive heat from the fi rebox.

13) 

Ensure all wires are pulled away from fi rebox 
to avoid excessive heat and secure with 
stick-on wire clip.

14)

 Re-attach control panel with 3 screws, re-

versing step 1. Re-attach rear access panel 
with 6 screws, reversing step 5.

NOTE: When power cord is plugged in, speed 
control is in the ON position and stove is 
burning, allow 10 - 15 minutes for the ther-
modisc (temperature switch) to activate and 
turn on the Fan automatically.

WARNING:  
Electrical Grounding Instructions
This appliance is equipped with 
a three pronged (grounding) plug 
for your protection against shock 
hazard and should be plugged 
directly into a properly grounded 
three-prong receptacle. Do not cut 
or remove the grounding prong 
from this plug.

INSTALLATION

Содержание H35-LP1

Страница 1: ...ncy or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas...

Страница 2: ...hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H35 has been approved by Warnock Hersey for both safety an...

Страница 3: ...5 INSTALLATION Speci cations 6 Information for Mobile Manufactured Homes After First Sale 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove...

Страница 4: ...one COPY OF SAFETY LABEL For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exibl...

Страница 5: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 6: ...or use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THIS APPLIANCE SHOULD BE INSTALLED REPAIRED INSPECTED BE FORE USE AND AT LEA...

Страница 7: ...nt Kit d Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Maintenance Instruction section If converting to Propane make...

Страница 8: ...e cut or remove the 3 aluminum air intake pipes Hint for pushing fan down onto pins rub a bit of dish soap on the pins so the grommets will slide down more easily Check to make sure the fan is seated...

Страница 9: ...Vent Direct Vent System Model DV GS venting systems in combination with the Direct Vent Freestanding Gas Stoves H35 NG1 and H35 LP1 have been tested and listed as direct vent heater systems by Warnoc...

Страница 10: ...p min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent ou...

Страница 11: ...V 08AB 911B 4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjusta...

Страница 12: ...A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 13: ...ct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direc...

Страница 14: ...below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Residential Manufactured and Mobile...

Страница 15: ...Arrangements Straight Horizontal Termination at a De Rated BTU The diagrams show all allowable combina tionsofstraighthorizontalterminationusing Rigid Pipe Restrictor position A Refer to the Conversio...

Страница 16: ...otal vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 8 feet total vertical and m...

Страница 17: ...en 90o elbows is required Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet tot...

Страница 18: ...nting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contour...

Страница 19: ...he 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent...

Страница 20: ...ater from enter ing and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex lin...

Страница 21: ...iredfor vertical to horizontal type installations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not ll air spaces with insulation The minimu...

Страница 22: ...apter is installedontheunitatthefactory Assemble the desired combination of pipe and elbows to the appliance adapter with pipe seams orientedtowardsthewallorceiling asmuch out of view as possible The...

Страница 23: ...es Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet meta...

Страница 24: ...ormance issues not covered under warranty Silicone red RTV is optional INSTALLATION 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the...

Страница 25: ...led before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure and or leaky chimneycon...

Страница 26: ...ri ce Size 33 DMS Convertible to Max Input Rating 30 000 Btu h Min Input Rating 14 300 Btu h Ori ce Size 37 DMS Propane Max Input Rating 34 000 Btu h Min Input Rating 17 500 Btu h Ori ce Size 51 DMS C...

Страница 27: ...te Any damage due to carboning re sulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Hamp ton Instal...

Страница 28: ...lot cap to expose the pilot orifice Remove the 2 screws push Burner Assembly to the left and lift out Burner Ori ce Installation of LPG Conversion Kit 1 Shut off the gas supply 2 H35 1 Lift off the Ca...

Страница 29: ...with the red o ring visible Fig 5 16 Reassemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type LPG Configuration Red o rin...

Страница 30: ...or place this in a convenient location away from the heat source 14 Tie up the loose wire with the wire clip Installation of the DC Sparker for the P90 Units Only 1 Locate the Piezo Ignitor situated...

Страница 31: ...wire from kit 9 Plug the DC spark generator wires to the DC Sparker 10 Connect the ground wire to the DC Sparker mounting bracket 12 Mount the heat shield to the DC Sparker Secure into place with the...

Страница 32: ...1 918 149 Decal Converted to 28 500 Btu 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more detailed instructi...

Страница 33: ...Tighten the screws Vent Restrictor setting at Low Btu for Straight Horizontal Venting 11 Attach the label This unit has been con verted to on top of the Serial decal over the higher Btu information 12...

Страница 34: ...on the burner tray Bracket Side View G 02 48 13 Test re to ensure proper light off make sure ame ows smoothly from one end of burner to the other If there is any ame hesitation check that area for any...

Страница 35: ...sides of the Front Casting 3 Fasten the Right Door to the 2 right hinges 2 screws per hinge Repeat for the Left Door TILE INSET INSTALLATION Side Tile Inset 1 Slide the Standard Side Tile Inset out t...

Страница 36: ...of the stove 2 Release the catches on the left and right side of the stove that secure the glass 3 Remove the glass by sliding it up and out 4 Pull all four door hinges out from the sides of the fron...

Страница 37: ...er failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do...

Страница 38: ...aximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Страница 39: ...t the logs have been incorrectly positioned 7 The unit should never be turned off and on again without a minimum of a 60 second wait 1 Choose a convenient location on the wall to install the receiver...

Страница 40: ...control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do n...

Страница 41: ...lve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WA...

Страница 42: ...e unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If...

Страница 43: ...n 11 mm wrench 16 Remove valve to ori ce nut with a 13 16 wrench 17 Remove inlet pipe with pipe wrench Note orientation of 90o elbow 18 Remove two 2 phillips head M5 screws on each side of the valve 1...

Страница 44: ...740 077 Side Insert Bracket 56 W842051 Gasket Upper Air Passage Top 57 W260108 Gasket Upper Air Passage Bottom 58 630 009 Gasket Lower Air Passage 59 Upper Air Passage Assy 61 945F Direct Vent Adaptor...

Страница 45: ...ly Gasket 69 Valve Shield 70 Valve Bracket 71 Valve Gasket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 730 550 Burner Assy 740 546 Base Assembly 79 Ba...

Страница 46: ...46 Hampton H35 Direct Vent Freestanding Gas Stove NOTES...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer de...

Страница 48: ...________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with reliability and simplicity in m...

Отзывы: