Hampton

®

 H35 Direct Vent Freestanding Gas Stove

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The  Direct Vent Freestanding Gas Stove must be 
installed in accordance with these instructions. 
Carefully read all the instructions in this manual 
fi rst. Consult the building authority having 
jurisdiction to determine the need for a permit 
prior to starting the installation.

Note: Failure to follow the instructions 

could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or property 
damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.

Note: These instructions take precedence over 

Simpson Dura-Vent instructions.

SPECIFICATIONS

Fuels: 

H35-NG1 is approved for use with 
natural gas.

 

H35-LP1 is approved for use 
with liquefied petroleum gases 
(propane).

Electrical:

  120V  A.C. system.

Circulation Fan: 

 Variable speed, 125/75.

Log Sets: 

 Ceramic fi bre, 7 per set.

Vent System:

 Coaxial (6-5/8" outer / 4" inner 

liner) rigid fl ue and termination cap.

The effi ciency rating of the appliance is a 
product thermal effi ciency  rating  determined 
under continuous operating conditions and 
was determined independent of any installed 
system.

INFORMATION FOR 

MOBILE / 

MANUFACTURED 

HOMES 

AFTER FIRST SALE

This Hampton

®

 product has been tested and 

listed by ITS Testing Services as a Direct Vent 
Wall Furnace to the following standards:  
CGA-2.17-M91, and ANSI Z21.88b-2003/CSA 
2.33b-2003.

This Direct Vent System Appliance must be 
installed in accordance with the manufacturer's 
installation instructions and the Manufactured 

INSTALLATION

Home Construction and Safety Standard, Title 
24 CFR, Part 3280, or the current Standard 
of Fire Safety Criteria for Manufactured 
Home Installations, Sites, and Communities 
ANSI/NFPA 501A, and with CAN/CSA Z240-MH 
Mobile Home Standard in Canada.

This appliance installation must comply with 
the manufacturer's installation instructions and 
local codes, if any. In the absence of local codes 
follow the current National Fuel Gas Code, ANSI 
Z223.1 and the current National Electrical Code 
ANSI/NFPA 70 in the U.S.A., and the current 
CAN/CGA B149 Gas Installation Code and the 
current Canadian Electrical Code CSA C22.1 
in Canada.

This Hampton

®

 Mobile/Manufactured 

Home Listed appliance comes factory 
equipped with a means to secure the 
unit.

This Hampton

®

 Mobile/Manufactured 

Home listed appliance comes equipped 
with a dedicated #8 ground lug to which 
an 18 gauge copper wire from the steel 
chassis ground must be attached.

This appliance may only be installed in 
an aftermarket permanently located, 
manufactured (USA only )or mobile 
home, where not prohibited by local 
codes.

This appliance is only for use with 
the type of gas indicated on the 
rating plate. This appliance is not 
convertible for use with other gases, 
unless a certifi ed kit is used.

INSTALLATION AND REPAIRS SHOULD 
BE DONE BY A QUALIFIED SERVICE 
PERSON. THIS APPLIANCE SHOULD BE 
INSTALLED, REPAIRED, INSPECTED BE-
FORE USE AND AT LEAST ANNUALLY BY 
A QUALIFIED SERVICE PERSON.  MORE 
FREQUENT CLEANING MAY BE REQUIRED 
DUE TO EXCESSIVE LINT FROM CARPET-
ING, ETC.  IT IS IMPERATIVE THAT THE 
CONTROL COMPARTMENT, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 

OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE AP-
PLIANCE SHOULD BE LOCATED OUT OF 
TRAFFIC AND AWAY FROM FURNITURE 
AND DRAPERIES.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however, we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:

1)

  Provide adequate clearances for servicing, 

proper operation and around the air openings 
into the combustion chamber. 

2)

  The appliance must be installed on a fl at, 

solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or it can be 
raised up on a platform to enhance its visual 
impact. The appliance may be installed on 
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's 
base extends the full width and depth of the 
appliance. The  Direct Vent Freestanding 
Gas Stove can be installed in a wide variety 
of ways and will fi t nearly any room layout. 
It may be installed in a recessed position, 
framed out into the room, or across a cor-
ner.

3)

  The  Direct Vent Freestanding Gas Stove  

is approved for alcove installations, which 
meet the clearances listed in the "Clear-
ance to Combustibles" section.  This unit is 
approved for manufactured home installa-
tions, see the "Manufactured Mobile Home 
Additional Requirements" section and the 
"Venting Arrangement" section for the re-
quired vent arrangements. If installed into a 
manufactured home the unit must be bolted 
down to the fl oor. 

4)

  This appliance is Listed for bedroom  instal-

lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.

5)

  This appliance is Listed for Alcove installa-

tions, maintain minimum Alcove clearances 
as follows,   minimum width of 40" (1016mm), 
a maximum depth of 36" (914mm), and 
minimum ceiling height of 64" (1626mm) 
from fl oor to ceiling.

6)

  We recommend that you plan your instal-

lation on paper using exact measurements 
for clearances and fl oor protection before 
actually installing this appliance.  Have a 
qualifi ed building inspector review your plans 
before installation.

WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID 
YOUR WARRANTY AND MAY CAUSE A 
SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES, ESPECIALLY 
THE FIREPLACE GLASS, AND SHOULD 
STAY AWAY TO AVOID BURNS OR CLOTH-
ING IGNITION.  

YOUNG CHILDREN SHOULD BE CARE-
FULLY  SUPERVISED WHEN THEY ARE IN 
THE SAME ROOM AS THE APPLIANCE.  

CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED ON 

OR NEAR THE APPLIANCE. 

Содержание H35-LP1

Страница 1: ...ncy or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas...

Страница 2: ...hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H35 has been approved by Warnock Hersey for both safety an...

Страница 3: ...5 INSTALLATION Speci cations 6 Information for Mobile Manufactured Homes After First Sale 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove...

Страница 4: ...one COPY OF SAFETY LABEL For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exibl...

Страница 5: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 6: ...or use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THIS APPLIANCE SHOULD BE INSTALLED REPAIRED INSPECTED BE FORE USE AND AT LEA...

Страница 7: ...nt Kit d Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Maintenance Instruction section If converting to Propane make...

Страница 8: ...e cut or remove the 3 aluminum air intake pipes Hint for pushing fan down onto pins rub a bit of dish soap on the pins so the grommets will slide down more easily Check to make sure the fan is seated...

Страница 9: ...Vent Direct Vent System Model DV GS venting systems in combination with the Direct Vent Freestanding Gas Stoves H35 NG1 and H35 LP1 have been tested and listed as direct vent heater systems by Warnoc...

Страница 10: ...p min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent ou...

Страница 11: ...V 08AB 911B 4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjusta...

Страница 12: ...A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 13: ...ct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direc...

Страница 14: ...below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Residential Manufactured and Mobile...

Страница 15: ...Arrangements Straight Horizontal Termination at a De Rated BTU The diagrams show all allowable combina tionsofstraighthorizontalterminationusing Rigid Pipe Restrictor position A Refer to the Conversio...

Страница 16: ...otal vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 8 feet total vertical and m...

Страница 17: ...en 90o elbows is required Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet tot...

Страница 18: ...nting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contour...

Страница 19: ...he 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent...

Страница 20: ...ater from enter ing and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex lin...

Страница 21: ...iredfor vertical to horizontal type installations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not ll air spaces with insulation The minimu...

Страница 22: ...apter is installedontheunitatthefactory Assemble the desired combination of pipe and elbows to the appliance adapter with pipe seams orientedtowardsthewallorceiling asmuch out of view as possible The...

Страница 23: ...es Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet meta...

Страница 24: ...ormance issues not covered under warranty Silicone red RTV is optional INSTALLATION 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the...

Страница 25: ...led before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure and or leaky chimneycon...

Страница 26: ...ri ce Size 33 DMS Convertible to Max Input Rating 30 000 Btu h Min Input Rating 14 300 Btu h Ori ce Size 37 DMS Propane Max Input Rating 34 000 Btu h Min Input Rating 17 500 Btu h Ori ce Size 51 DMS C...

Страница 27: ...te Any damage due to carboning re sulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Hamp ton Instal...

Страница 28: ...lot cap to expose the pilot orifice Remove the 2 screws push Burner Assembly to the left and lift out Burner Ori ce Installation of LPG Conversion Kit 1 Shut off the gas supply 2 H35 1 Lift off the Ca...

Страница 29: ...with the red o ring visible Fig 5 16 Reassemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type LPG Configuration Red o rin...

Страница 30: ...or place this in a convenient location away from the heat source 14 Tie up the loose wire with the wire clip Installation of the DC Sparker for the P90 Units Only 1 Locate the Piezo Ignitor situated...

Страница 31: ...wire from kit 9 Plug the DC spark generator wires to the DC Sparker 10 Connect the ground wire to the DC Sparker mounting bracket 12 Mount the heat shield to the DC Sparker Secure into place with the...

Страница 32: ...1 918 149 Decal Converted to 28 500 Btu 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more detailed instructi...

Страница 33: ...Tighten the screws Vent Restrictor setting at Low Btu for Straight Horizontal Venting 11 Attach the label This unit has been con verted to on top of the Serial decal over the higher Btu information 12...

Страница 34: ...on the burner tray Bracket Side View G 02 48 13 Test re to ensure proper light off make sure ame ows smoothly from one end of burner to the other If there is any ame hesitation check that area for any...

Страница 35: ...sides of the Front Casting 3 Fasten the Right Door to the 2 right hinges 2 screws per hinge Repeat for the Left Door TILE INSET INSTALLATION Side Tile Inset 1 Slide the Standard Side Tile Inset out t...

Страница 36: ...of the stove 2 Release the catches on the left and right side of the stove that secure the glass 3 Remove the glass by sliding it up and out 4 Pull all four door hinges out from the sides of the fron...

Страница 37: ...er failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do...

Страница 38: ...aximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Страница 39: ...t the logs have been incorrectly positioned 7 The unit should never be turned off and on again without a minimum of a 60 second wait 1 Choose a convenient location on the wall to install the receiver...

Страница 40: ...control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do n...

Страница 41: ...lve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WA...

Страница 42: ...e unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If...

Страница 43: ...n 11 mm wrench 16 Remove valve to ori ce nut with a 13 16 wrench 17 Remove inlet pipe with pipe wrench Note orientation of 90o elbow 18 Remove two 2 phillips head M5 screws on each side of the valve 1...

Страница 44: ...740 077 Side Insert Bracket 56 W842051 Gasket Upper Air Passage Top 57 W260108 Gasket Upper Air Passage Bottom 58 630 009 Gasket Lower Air Passage 59 Upper Air Passage Assy 61 945F Direct Vent Adaptor...

Страница 45: ...ly Gasket 69 Valve Shield 70 Valve Bracket 71 Valve Gasket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 730 550 Burner Assy 740 546 Base Assembly 79 Ba...

Страница 46: ...46 Hampton H35 Direct Vent Freestanding Gas Stove NOTES...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer de...

Страница 48: ...________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with reliability and simplicity in m...

Отзывы: