HAMPTON BAY H35-LP1 Скачать руководство пользователя страница 40

40

Hampton

®

 H35 Direct Vent Freestanding Gas Stove

COPY OF THE LIGHTING PLATE INSTRUCTIONS 

OPERATING INSTRUCTIONS

AUTOMATIC 

CONVECTION 

FAN OPERATION

The fan operates automatically - turn the knob at 
the top right rear corner to adjust to the desired 
speed. The fan will turn on as the stove comes 
up to operating temperature. After the unit has 
been turned off and the unit cooled to below a 
useful heat output range the fan will shut off 
automatically.

1)  Push in gas control knob slightly and turn to “PILOT” position.

2)  Push in control knob all the way and hold  in until the pilot lights 

up. Continue to hold the control knob in for about 20 seconds 
after the pilot is lit. Release knob.

3) Push in gas control knob slightly and turn to "ON" position.

4) Turn ON the fl ame switch.

2) Wait fi ve (5) minutes  to clear out any gas. If you then smell gas 

STOP! follow “B” in the safety information above on this label. If 
you don’t smell gas, go to the next step.

3)  Turn knob  on gas control counterclockwise           to “PILOT”.

4) Push in control knob all the way and hold in.  Immediately push 

black button on spark igniter until pilot lights. Continue to hold the 
control knob in for about 1/2 minute after the pilot is lit. Release 
knob and it will pop back up. Pilot should remain lit. If it goes out, 
repeat steps 3) and 4). 

 

If knob does not pop up when released, stop and immediately call 
your service technician or gas supplier.

 

 If the pilot will not stay lit after several tries, turn the gas control 
knob to “OFF” and call your service technician or gas supplier.

5)  Turn gas control knob counterclockwise        to “ON”.

6)  Use rocker switch to operate main burner.

DO NOT REMOVE THIS INSTRUCTION PLATE

FOR YOUR SAFETY READ BEFORE LIGHTING

A)

  This appliance has a pilot which must be lighted by  hand,  following  the  instructions below  exactly.

B)

  BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor because some gas is heavier than 

air and will settle on the fl oor.

      WHAT TO DO IF YOU SMELL GAS
 

-  Do not try to light any appliance

 

-  Do not touch any electric switch, do not use any phone in your building

 

-  Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.

 

-  If you cannot reach your gas supplier, call the fi re department.

C)

  Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to 

repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or explosion.

D)

  Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and 

to replace any part of the control system and any gas control which has been under water.

E) 

 This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

918-474a

Gas Inlet

OFF

WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, 
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause 
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance 
or additional information consult a qualifi ed installer, service agency or gas supplier.

 LIGHTING INSTRUCTIONS

TO TURN OFF GAS APPLIANCE

THERMOPILE
ELEMENT
THERMO-
ELECTRIQUE

PILOT BURNER
VEILLEUSE

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/

NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)

FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK: 

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures 
keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner 
and control compartment clean. See installation and operating instructions accompanying appliance.

STOP! Read the safety information above on this label.

FOR ALL PROPANE UNITS AND 

UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:

1)  Push in gas control knob slightly and turn clockwise           to  

“OFF”.  Knob  cannot  be  turned  from  “PILOT” to “OFF” unless 
knob is pushed in slightly. Do not force.

Gas Inlet

1 )  Tu r n   o ff   t h e   f l a m e   s w i t c h .
2 )   P u s h   i n   t h e   g a s   c o n t r o l   k n o b   s l i g h t l y   a n d   t u r n   c l o c k w i s e                   t o   “ O F F ” .   D o   n o t   f o r c e .
3 )  Tu r n   o ff   a l l   e l e c t r i c   p o w e r   t o   t h e   a p p l i a n c e   i f   s e r v i c e   i s   t o   b e   p e r f o r m e d .  

       Yo u   m a y   s h u t   o ff   t h e   p i l o t   d u r i n g   p r o l o n g e d   n o n   u s e   p e r i o d s   t o   c o n s e r v e   f u e l .

ADJUSTING FLAME 

HEIGHT

 
Your heater has an adjustable fl ame to tailor the 
look and heat output to your specifi c needs. It 
is adjusted by turning the fl ame adjustment dial 
on the gas control valve.

Turn clockwise to adjust the fl ame higher, coun-
terclockwise for a lower fl ame.

Содержание H35-LP1

Страница 1: ...ncy or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas...

Страница 2: ...hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H35 has been approved by Warnock Hersey for both safety an...

Страница 3: ...5 INSTALLATION Speci cations 6 Information for Mobile Manufactured Homes After First Sale 6 General Safety Information 7 Installation Checklist 7 Clearances to Combustibles 7 Locating Your Gas Stove...

Страница 4: ...one COPY OF SAFETY LABEL For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachusetts exibl...

Страница 5: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 6: ...or use with other gases unless a certi ed kit is used INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THIS APPLIANCE SHOULD BE INSTALLED REPAIRED INSPECTED BE FORE USE AND AT LEA...

Страница 7: ...nt Kit d Dura Vent Termination Kit 5 Make gas connections Refer to the Gas Connection section Test the pilot Must be as per diagram in the Maintenance Instruction section If converting to Propane make...

Страница 8: ...e cut or remove the 3 aluminum air intake pipes Hint for pushing fan down onto pins rub a bit of dish soap on the pins so the grommets will slide down more easily Check to make sure the fan is seated...

Страница 9: ...Vent Direct Vent System Model DV GS venting systems in combination with the Direct Vent Freestanding Gas Stoves H35 NG1 and H35 LP1 have been tested and listed as direct vent heater systems by Warnoc...

Страница 10: ...p min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent ou...

Страница 11: ...V 08AB 911B 4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjusta...

Страница 12: ...A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 13: ...ct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direc...

Страница 14: ...below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Residential Manufactured and Mobile...

Страница 15: ...Arrangements Straight Horizontal Termination at a De Rated BTU The diagrams show all allowable combina tionsofstraighthorizontalterminationusing Rigid Pipe Restrictor position A Refer to the Conversio...

Страница 16: ...otal vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 8 feet total vertical and m...

Страница 17: ...en 90o elbows is required Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet tot...

Страница 18: ...nting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contour...

Страница 19: ...he 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent...

Страница 20: ...ater from enter ing and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the 4 dia ex lin...

Страница 21: ...iredfor vertical to horizontal type installations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not ll air spaces with insulation The minimu...

Страница 22: ...apter is installedontheunitatthefactory Assemble the desired combination of pipe and elbows to the appliance adapter with pipe seams orientedtowardsthewallorceiling asmuch out of view as possible The...

Страница 23: ...es Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet meta...

Страница 24: ...ormance issues not covered under warranty Silicone red RTV is optional INSTALLATION 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the...

Страница 25: ...led before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressure and or leaky chimneycon...

Страница 26: ...ri ce Size 33 DMS Convertible to Max Input Rating 30 000 Btu h Min Input Rating 14 300 Btu h Ori ce Size 37 DMS Propane Max Input Rating 34 000 Btu h Min Input Rating 17 500 Btu h Ori ce Size 51 DMS C...

Страница 27: ...te Any damage due to carboning re sulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Hamp ton Instal...

Страница 28: ...lot cap to expose the pilot orifice Remove the 2 screws push Burner Assembly to the left and lift out Burner Ori ce Installation of LPG Conversion Kit 1 Shut off the gas supply 2 H35 1 Lift off the Ca...

Страница 29: ...with the red o ring visible Fig 5 16 Reassemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type LPG Configuration Red o rin...

Страница 30: ...or place this in a convenient location away from the heat source 14 Tie up the loose wire with the wire clip Installation of the DC Sparker for the P90 Units Only 1 Locate the Piezo Ignitor situated...

Страница 31: ...wire from kit 9 Plug the DC spark generator wires to the DC Sparker 10 Connect the ground wire to the DC Sparker mounting bracket 12 Mount the heat shield to the DC Sparker Secure into place with the...

Страница 32: ...1 918 149 Decal Converted to 28 500 Btu 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more detailed instructi...

Страница 33: ...Tighten the screws Vent Restrictor setting at Low Btu for Straight Horizontal Venting 11 Attach the label This unit has been con verted to on top of the Serial decal over the higher Btu information 12...

Страница 34: ...on the burner tray Bracket Side View G 02 48 13 Test re to ensure proper light off make sure ame ows smoothly from one end of burner to the other If there is any ame hesitation check that area for any...

Страница 35: ...sides of the Front Casting 3 Fasten the Right Door to the 2 right hinges 2 screws per hinge Repeat for the Left Door TILE INSET INSTALLATION Side Tile Inset 1 Slide the Standard Side Tile Inset out t...

Страница 36: ...of the stove 2 Release the catches on the left and right side of the stove that secure the glass 3 Remove the glass by sliding it up and out 4 Pull all four door hinges out from the sides of the fron...

Страница 37: ...er failure the burner switch and the optional remote control thermostat will continue to operate However a 120V A C power supply is needed for the fan blower operation Caution Ensure that the wires do...

Страница 38: ...aximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Страница 39: ...t the logs have been incorrectly positioned 7 The unit should never be turned off and on again without a minimum of a 60 second wait 1 Choose a convenient location on the wall to install the receiver...

Страница 40: ...control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do n...

Страница 41: ...lve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WA...

Страница 42: ...e unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If...

Страница 43: ...n 11 mm wrench 16 Remove valve to ori ce nut with a 13 16 wrench 17 Remove inlet pipe with pipe wrench Note orientation of 90o elbow 18 Remove two 2 phillips head M5 screws on each side of the valve 1...

Страница 44: ...740 077 Side Insert Bracket 56 W842051 Gasket Upper Air Passage Top 57 W260108 Gasket Upper Air Passage Bottom 58 630 009 Gasket Lower Air Passage 59 Upper Air Passage Assy 61 945F Direct Vent Adaptor...

Страница 45: ...ly Gasket 69 Valve Shield 70 Valve Bracket 71 Valve Gasket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 730 550 Burner Assy 740 546 Base Assembly 79 Ba...

Страница 46: ...46 Hampton H35 Direct Vent Freestanding Gas Stove NOTES...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer de...

Страница 48: ...________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with reliability and simplicity in m...