operating instructions

FIRST FIRE

The first fire in your stove is part of the paint curing 

process. To ensure that the paint is properly cured, 

it  is  recommended  that  you  burn  your  fireplace 

for at least four (4. hours the first time you use 

it  with  the  fan  on.  When  first  operated,  the  unit 

will release an odour caused by the curing of the 

paint, the burning off of any oils remaining from 

manufacturing. Smoke detectors in the house may 

go off at this time. Open a few windows to ventilate 

the room for a couple of hours. 

The glass panel may require cleaning after the unit 

has cooled down.  

DO NOT ATTEMPT TO CLEAN THE 

GLASS WHILE IT IS HOT. 

Note:  When the glass is cold and the appliance 

is lit, it may cause condensation and fog 

the glass. This condensation is normal 

and will disappear in a few minutes as 

the glass heats up.

OPERATING  

INSTRUCTIONS

1.

  Read and understand these instructions before 

operating this appliance.

2.

  Check  to  see  that  all  wiring  is  correct  and 

enclosed to prevent possible shock.

3.

  Check to ensure there are no gas leaks.

4.

  Make sure the glass in the door frame is properly 

positioned. Never operate the appliance with 

the glass removed.

5.

  Verify that the venting and cap are unobstructed.

6.

  Verify log placement. If the pilot cannot be 

seen when lighting the unit, the logs have been 

incorrectly positioned.

7.

  The unit should never be turned off, and on 

again without a minimum of a 60 second wait.

During  the  first  few  fires,  a  white  film 

may  develop  on  the  glass  front  as  part 

of the curing process. The glass should 

be cleaned

 or the film will bake on and 

become  very  difficult  to  remove.  Use  a 

non-abrasive cleaner and NEVER clean 

the glass while it is hot.

DO NOT BURN THE APPLIANCE 

WITHOUT THE GLASS FRONT IN 

PLACE.

8.

   Remote  control  requires  coding.  See  remote 

coding  instructions for details. 

NOTE:

 This appliance will operate with 4 AA back-up 

batteries installed (see Back-up Battery section 

for details) during power outages. Only the fan 

and light will not operate until power is restored. 

If the remote is misplaced, the unit can be shut 

off by flipping the main 

ON/OFF

 switch, located 

behind the front cover plate, to the 

OFF

 position.

IMPORTANT:

 The remote control system supplied 

with this appliance has several options for 

starting/operating the appliance, please read the 

remote control operating instructions (packed 

with remote control) to understand how to 

operate this remote system. You can download 

remote functions video with the QR code below.

Содержание H27-LP10

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Страница 2: ...has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H27 10 has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...System 21 DV Stove Horizontal Vent Kit 22 Residential And Manufactured Homes Mobile Homes 24 Minimum Horizontal Termination Installations 24 Dura Vent Termination Kit 25 Horizontal Terminations 26 Ve...

Страница 4: ...ight Side Wall Vertical Pipe See Manual for details Model Modele H27 NG10 Model Modele H27 LP10 Part 919 485a Colour Everything black on grey except for items indicated as being printed in red Size Pr...

Страница 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 6: ...6 Hampton H27 10 Direct Vent Freestanding Gas Stove 6 dimensions UNIT DIMENSIONS WITH VERTICAL VENTING 17 13 16 452 mm...

Страница 7: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 7 7 installation UNIT DIMENSIONS WITH HORIZONTAL VENTING 452 mm...

Страница 8: ...alfirst Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of th...

Страница 9: ...f the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpassingthrough...

Страница 10: ...wall if installing the blower option so the fan can be easily installed and or serviced LOCATING YOUR GAS STOVE When selecting a location for your stove ensure that the clearances listed above are met...

Страница 11: ...n the back of the left side access panel 7 Loosen the 2 bolts on fan assembly and slide the fan into the slots provided on the unit 8 Once the fan assembly is fitted into the assigned slots tighten th...

Страница 12: ...e steps OPTIONAL WALL THERMOSTAT INSTALLATION 1 Open the front panel and remove the cover plate by removing two screws 2 Disconnect one of the wires from the switch as shown in the picture below to co...

Страница 13: ...logy Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room...

Страница 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air...

Страница 15: ...Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvani...

Страница 16: ...Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4...

Страница 17: ...nt Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd D...

Страница 18: ...m two 45o elbows If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for...

Страница 19: ...of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total ve...

Страница 20: ...feet total horizontal Please note min 1 foot between 90o elbows is re quired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated...

Страница 21: ...to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdi...

Страница 22: ...th the starter collar and the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent terminal 2 Assembleatrialf...

Страница 23: ...and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner out fully and get a trial fit of the liner onto the 4...

Страница 24: ...rements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall ensure that...

Страница 25: ...ical to horizontal type installations Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancereq...

Страница 26: ...enetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towa...

Страница 27: ...dden on the final installation NOTE For best results and optimum performancewitheachapprovedventing system it is highly recommended to ap ply Mill Pac sealant supplied toevery inner pipe connection Fa...

Страница 28: ...lt in drafting or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportBox Ins...

Страница 29: ...y chimneys cleanout doors and caps or plugs for cleanout tee fittings and ash dumps shall be secured in place and sealed before install ing a Direct Vent system within the chimney If the appliance shu...

Страница 30: ...Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 5 0 2 w c Propane 10 0 2 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide sto...

Страница 31: ...the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pres sure...

Страница 32: ...ll off the pilot cap to expose the pilot orifice 6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1...

Страница 33: ...and refer to the dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b L...

Страница 34: ...ftheburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown below L...

Страница 35: ...ck for proper draft CAUTION Anyalterationtotheproductthatcausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer BACK UP BATTERY In the event of a power...

Страница 36: ...ot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be...

Страница 37: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Страница 38: ...ned Never operate the appliance with the glass removed 5 Verifythattheventingandcapareunobstructed 6 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrec...

Страница 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Страница 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Страница 41: ...at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREAND...

Страница 42: ...ocheckmechanicalsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and al...

Страница 43: ...o stove 4 Disconnect gas line to stove 5 Disconnect 3 8 NPT pipe from 90o elbow on valve or flex connector 6 Disconnect 3 wires from spark igniter assembly 7 Lift off the Cast Top and remove the Cast...

Страница 44: ...ctor 350 004 Baffle Plate for Firebox Part Description Part Description Part Description 350 022 Casting Mount Bracket Fan Air Divider 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52...

Страница 45: ...Halogen Light Socket Assembly 910 997 Halogen Light Bulb 120 Volt 20 Watt JCD Bi Pin Gy6 35 910 157 P Blower Motor Only with Squirrel Cage 911 093 10 foot Extension Cord 911 027 Battery Holder W 9V Sn...

Страница 46: ...46 Hampton H27 10 Direct Vent Freestanding Gas Stove 46 notes...

Страница 47: ...d if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufactur...

Страница 48: ...________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___...

Отзывы: