Regency Pellet Products Warranty 

 

 

Replacement units are limited to one per warranty term.  Airtube and baffle replacements are limited to one 

replacement per term. 

 

Unit must be installed according to all manufacturers’ instructions as per the manual. 

 

All Local and National required codes must be met. 

 

The installer is responsible to ensure the unit is operating as designed at the time of installation. 

 

The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual.  As 

outlined below, the warranty may be voided due to problems caused by lack of maintenance.  

 

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit 

will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced 

at our discretion. No labor coverage is included with these parts 

 

Exclusions: 

This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance 

or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), inner panels, door 

or glass gasketing, or any other additional factory fitted gasketing. 

 

Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical 

damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components 

(including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels (plastics, 

garbage, solvents, cardboard, coal or coal products, oil based products, waxed cartons, compressed pre-

manufactured logs), lack of regular maintenance and upkeep, acts of God, weather related problems from 

hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in 

malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty.  

 

FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications 

or upgrades will not be performed on existing appliances). 

 

This warranty does not cover dealer travel costs for diagnostic or service work. All labor rates paid to authorized 

dealers are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time 

beyond their subsidy. 

 

Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may 

void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or 

corroded within three (3) months of installation/purchase. 

 

Units which show evidence of being operated while damaged, or with problems known to the purchaser and 

causing further damages will void this warranty. 

 

Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty. 

 

Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this 

warranty. 

 

FPI is not liable for the removal or replacement of facings or finishing in order to repair or replace any appliance in 

the field. 

 

Freight damages for products or parts are not covered under the terms of the warranty. 

 

Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior 

authorization from FPI may void this warranty. 

 

 

Содержание Greenfire GC60-2

Страница 1: ...er or service agency Tested by Greenfire GC60 2 OWNER S MANUAL Freestanding Cast Iron Pellet Stove Contact your building or fire officials about restrictions and installation inspection requirements i...

Страница 2: ...ds Under specific test condition this heater has been shown to deliver heat at rates raging from 7 817 38 437 Btu hr Efficiency 78 HHV PFS TECO 21 703 When using optional top vent adaptor kit GC60 920...

Страница 3: ...rating Instructions 7 Dimensions Specifications 7 Control Board Functions 8 Automatic Safety Features of Your Pellet Stove 8 Operating Your Pellet Stove 9 Turning Your Pellet Stove Off 10 Slider Dampe...

Страница 4: ...may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the burning process This hard mass will block the air...

Страница 5: ...r and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also ensure all gaskets on the door are checked and re...

Страница 6: ...it can be installed on a hard stable combustible surface D L unit doit tre install e avec protection de plancher devant et au bord de la porte ouvrant avec au moins 6 152 mm La base de pi destal peut...

Страница 7: ...nstruction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT T...

Страница 8: ...age Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg hr Testing Standard Weight with full hopper Consumption on H...

Страница 9: ...ow to adjust setting 3 Light is the default setting Depending on Fuel quality Ignition problems may occur at higher altitudes this can be resolved by trimming the Combustion Fan to a higher setting 7...

Страница 10: ...until it has reached the designated heat setting Once a fire has been established the convection blower will turn on after ten 10 minutes To OPERATE Press the Heat Level buttons to change the desired...

Страница 11: ...Magnahelic pressure gauge once the unit has been running on heat level 5 setting after one hour of burn time This adjustment is necessary for varying venting configurations The reading can be taken fr...

Страница 12: ...and if required the slider damper to produce the proper clean combustion 1 Open the door using the door handle located on the right hand side of the stove 2 Lift the lever on burn pot to unlock the f...

Страница 13: ...and inside of the glass ASH PAN AND DOOR GASKETS Weekly After extended use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available fro...

Страница 14: ...ection It is very important that the stove be cleaned and serviced as stated above CLEANING PAINTED SURFACES Please clean surfaces with a soft damp cloth CLEANING ENAMEL SURFACES Enamel Finishes and p...

Страница 15: ...cture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s opt...

Страница 16: ...cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados e...

Страница 17: ...local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain...

Страница 18: ...order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Deta...

Страница 19: ...Hampton GC60 2 Cast Pellet Stove Owner s Manual 19...

Страница 20: ...the following information Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________...

Отзывы: