23
Operation (continued)
WARNING: NEVER light the burner with the
cover on the outdoor fire table.
CAUTION: Keep outdoor gas appliance area
clear and free from combustible materials,
gasoline and other flammable vapours and liquids.
CAUTION: Do NOT obstruct the flow of combustion and ventilation
air.
CAUTION: Check and clean burner/venturi tubes for insects and insect nests.
A clogged tube can lead to a fire.
LIGHTING
1. Make sure all labels, packaging and protective films have been removed from the outdoor fire table.
2. Remove cover and burner lid (if applicable) before operating fire table. Check for obstructions of airflow to the burner.
Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube can lead to a fire.
3. Control knob must be in the “OFF” position.
4. To ensure proper function, the screen on the pilot housing should not be covered by lava rocks.
5. Connect LP gas tank per Operation steps 1 and 2.
6. Turn LP gas tank valve to “OPEN”.
7. Push and hold the flame ignitor to create sparks within the electrode; and continue to hold.
8. Push in the control knob and turn to the “ON” position. Keep holding down the control knob toallow gas to flow for 20 seconds.
9. After 20 seconds, release and turn control knob counter-clockwise to adjust flame to desired height.
10. If ignition does not occur in 20 seconds turn burner control knob to “OFF”, wait five minutes, fan with a newspaper or
magazine, and repeat lighting procedure.
proper flame height
OFF
HOMEDEPT.CA
Please contact 1-855-HD-HAMPTON for further assistance.