background image

[email protected]  

 www.IP44.de

2.00   06/18

1 / 8

IP54

1.  Conduct mains cable through cable entry point of the 

wall bracket. Conduct aperture in cable entry point in 
such a way that density is assured.

2.  Attach wall bracket: Pay attention of position “top”.  

Use the washer gaskets with rubberized face showing to 
the wall bracket. At mounting holes which are not used 
arrange for density.

3.  Establish protective conductor connection and conduct 

electrical junction.

4.  Hustle light housing onto the wall bracket and assure it  

with countersunk head screws.

5.  Select lux- and time-setting.

6.  Click into place sensor head.

light technology:

IvyLight-technology
230V Power LED / 3000K 
system performance: 11 W/360 lm
 

EEC

technical information:

operating voltage 230V / 50Hz
 

protection class

 

safety class 1

 

Luminaire is suitable for mounting on normal inflammable  

 

fixing surfaces.

 

conformity mark

maintenance:

Disconnect the electrical installation.
This luminaire contains built-in LED lamps. The lamps cannot 
be replaced in the luminaire by the client.

A

care:

Regularly clean luminaire from dirt and deposits. Do not use a 
high pressure cleaner for cleaning.
Please note care instructions at www.IP44.de.
See service documents:
Care of stainless steel rustless or coated surfaces.

safety:

We point out that the electric connection of light fixtures has 
to be done by a certified installer.
We assume no accountability for damages which are a result 
of non-appropriate mounting or application of the luminaire.
Modifications on the luminaire will result in loss of warranty.

Please keep the instructions with the service documents!

intro control

instructions for use

Содержание intro control

Страница 1: ...ion operating voltage 230V 50Hz protection class safety class 1 Luminaire is suitable for mounting on normal inflammable fixing surfaces conformity mark maintenance Disconnect the electrical installat...

Страница 2: ...Bedienungsanleitung Sensor welcome IP44 de www IP44 de 2 00 06 18 2 8 sensor installation instructions...

Страница 3: ...2 1 For more information about picture 1 and 2 see page 6 welcome IP44 de www IP44 de 2 00 06 18 3 8 sensor installation instructions...

Страница 4: ...VDE 0100 A VE NORM E8001 1 CH SEV 1000 3 Only use genuine replacement parts 4 Repairs must only be made by specialised workshops Installation The site of installation should be at least 50 cm away fr...

Страница 5: ...cted 2 Switch light OFF when light is ON Turn switch OFF and ON once The light goes out or switches to sensor mode Manual override 1 Activate manual override Turn switch OFF and ON once The light is s...

Страница 6: ...1 2 welcome IP44 de www IP44 de 2 00 06 18 6 8 Functions Once installed the sensor can be put into operation Control dials are provided on the sensor unit for selec ting time twilight and pro gramme s...

Страница 7: ...n zone Sensor unit is not properly engaged Check detection zone and re adjust if necessary Lightly press sensor unit to clip it into place Sensor does not switch OFF at around midnight External light...

Страница 8: ...th 90 angle of aperture and sneak by guard Sensor reach 8 m max all round mounted at a height of 1 75 2 m Time setting 5 sec 15 min Twilight setting 2 2000 Lux ON time selectable 4 hours provided Swit...

Отзывы: