25
12.3 Batteries (Wet Lead Acid)
Hammerhead
batteries are rated for 500 charge cycles.
Every time the batteries are charged it uses one cycle.
To insure getting the expected life, unnecessary charging should be avoided.
The specific gravity will reflect the percentage of charge remaining in the
battery.
100% charge = 1.265 and above Specific Gravity
75 % charge = 1.225 Specific Gravity
50 % charge = 1.190 Specific Gravity
25 % charge = 1.120 Specific Gravity
Note : Gel maintenance free-batteries can not be tested with the hydrometer.
Do not attempt to open cell covers or caps. Doing so will destroy the battery.
All the fuses are located on the main
control circuit board.
Part Numbers
00059580 Fuse 125 Amp 80 Volts (Brush & Vac. Motors)
00972420 Fuse 100 Amp. 80 Volts (Brush & Vac. Motors)
00733630 Fuse 10 Amp. 32 or 80 Volts (Pump & Water Sol.)
00902440 Fuse 50 Amp. 80 Volts (Drive)
00972430 Fuse 2 Amp. 32 Volts (Switch)
Warning: Do not substitute the value
of the 50, 100 and 125 amp fuses.
They must be correct voltage and
amperage. Doing so will produce
system errors. Fuses are used as
shunts in the circuit.
Note: If the 2 amp fuse blows,
check the main contactor for
bad contacts.
13. Fuse Locations (Version 2 Controller)
Содержание 650RS
Страница 5: ...5 3 2 System Maintenance I 3 3 System Maintenance II...
Страница 17: ...17 10 Table of Error Codes...
Страница 18: ...18 11 24V 22A Charger 10 1 Operating Instructions 11 1 24V 22A Charger...
Страница 28: ...28...
Страница 29: ...28 17 Contactor Wiring Control Board To batteries and charger Proper wiring of the contactor is critical...
Страница 30: ...CONT ACT US 800 626 7835 Contact HammerHeadClean com HammerHeadClean com HAMMERHEAD ENGINEERED SIMPLICITY...