31
!
X
Y
Edge sanders
HS 950
Setup and installation
7.4 Chip extraction
Warning! Risk of injury!:
Vacuum hose must be flame-resistant and must conduct electricity! Be sure to use only genuine Hammer
vacuum hoses!
Note: As a rule, all units must be vacuumed during use. A time delayed socket is available as an accessory.
• The dust extractor must be connected to the machine
in such a manner that it runs in unison with the
machine.
• The dust extraction hoses must be electrically conduc-
tive and grounded to prevent electrostatic
build up.
• Use dust extractors with reduced dust emission to clean
dust from the machine.
• In addition, the vacuum performance must be sufficient
to achieve the required negative pressures and an air
speed of 20 m/s at the connector. (see “Technical
data”)
• Check the air speed before putting the machine into
operation for the first time and after essential changes.
• The dust extractor setup must be controlled before the
machine is put into operation for the first time. Check for
obvious defects on a daily basis and the efficiency on a
monthly basis.
Angle B:
1.
Place a 90° angle between the roller and the side
work table.
2.
Measure the distance Y and X.
The values X and Y
must be equal.
3.
Loosen the hexagonal screws.
Release the fixing screws
Setting - at X>Y:
•
Adjusting in the „-“ direction
Setting - at X<Y:
•
Adjusting in the „+“ direction
4.
Tighten the hexagonal screws.
Tighten the fixing screws
!
Socket head cap screw
"
Fixing screws
#
clamp
Fig. 7-13: Setting - Angle B
Содержание HS 950
Страница 17: ...17 Edge sanders HS 950 Technical specifications...
Страница 21: ...21 Edge sanders HS 950 Setting up the machine...
Страница 33: ...33 Edge sanders HS 950 Setup and installation...
Страница 43: ...43 Edge sanders HS 950 Operation...
Страница 51: ...51 Edge sanders HS 950 Electrical circuit diagram...
Страница 58: ...58 Edge sanders HS 950...
Страница 59: ...59 Edge sanders HS 950...