HK
-41702
Make sure that the lifebuoy line is not on the outward side of the release cord! This might entangle the lifebuoy in an activation situation.
9. Pull up the release cord through the ERU hole with the pilot line. Secure it with the manual safety pin.
10. Connect the power to the Release Switch.
11. The safety cover on the Release Switch shall be secured with some kind of easy-to- break seal, in order to avoid unintentional use of
the system.
12. The system is now ready for use. The ERU shall be changed after two years of service.