Hammar HM-0600 Скачать руководство пользователя страница 5

HK

-41702

COMPONENTS

PACKAGE

Part no.

HM-0600 

1.  One GRP holder with pre-installed metal spring holder. The GRP holder can 

be mounted on port or starboard side of the ship and no change of the 

metal spring holder is needed. Measurements and hole positions - please 

check enclosed drawing.

2.  One ERU (electric remote unit) with cord pre-installed on the metal holder. 

The ERU cable is 1,5m long and shall be well strapped to the GRP holder in 

order to avoid any damage by weather or wind.

3.  One Release Switch in protective box to be mounted at the wheelhouse or 

bridge, IP66 class. Colour: silky grey. If mounted outside it shall be protected 

by an outer protective enclosure. Maximum diameter for cable 12mm.  If 

the Release Switch shall be mounted flush in a bridge control panel please 

specify in the order - HM-0451 Release Switch for flush mounting. Measure

-

ments and hole position - please check enclosed drawing.

4.  One connector box in marine grade plastic, IP66 class. Colour: steel grey. 

Maximum diameter for cable 12mm. Measurements and hole positions - 

please check enclosed drawing.

5.  20m cable from connector box to release switch, marine approved, scree-

ned 2 x 0,75mm2, diameter 8mm. Longer lengths can be supplied on 

request by additional meter price. Maximum length of the installation is 

150m. The Hammar products are designed to handle any voltage drop, so 

there is no need to increase the cable dimensions more than our recom-

mendation. 

       Cable recommendations:  

 

       0 - 75m installation length: 2 x 0,75mm2 

       75 - 150m installation lenght: 2 x 1,5mm2. 

       Cables with a diameter larger than 12mm can not be handled in the cable  

       glands and terminal blocks. Electric power required is  24VDC emergency          

       power. 

6.  One manual safety pin in stainless steel.

7.  One pilot line for loading the lifebuoy.

8.  Installation manual and user guide.

Содержание HM-0600

Страница 1: ...HK 41702 INSTALLATION MANUAL HM 0600 LIFEBUOY RELEASE SYSTEM Mk II Complete package for electric water release...

Страница 2: ...wing or the enclosed document Test of the Lifebuoy Release System 7 The ERU is pre installed The ERU must be marked with its expiry date Markings must be done solely by a manufacturer of liferafts or...

Страница 3: ...lease cord through the ERU hole with the pilot line Secure it with the manual safety pin 10 Connect the power to the Release Switch 11 The safety cover on the Release Switch shall be secured with some...

Страница 4: ...nector box mounted close to the GRP holder and disconnect the flexible cable of the H20 ERU Connect the two connection wires from the Emulator to the terminals on the Connector box were the flexible c...

Страница 5: ...M 0451 Release Switch for flush mounting Measure ments and hole position please check enclosed drawing 4 One connector box in marine grade plastic IP66 class Colour steel grey Maximum diameter for cab...

Страница 6: ...cuum operated HM 0650 with release cord and installation manual in English HM 0406 Replacement kit for LifeBuoy System MkI ERU electric water activation HM 0500 with release cord metal ring cable tie...

Страница 7: ...HK 41702 Sideview Backview Frontview Topview 190 780 958 510 650 60 800 160 60 670 680 540 M8 x5 GRP HOLDER DRAWING...

Страница 8: ...709 65 50 Fax 46 31 49 70 23 Drawn Ritad Checked Kontr Appr Godk nd Scale skala Repl Ers tter Date Datum dd mm yyyy Draw No Ritn nr Det Number ant Designation ben mn Sheet1 Notes noteringar Material...

Страница 9: ...Datum Repl Ers tter Scale skala Draw No Ritn nr Det Number ant Designation ben mn Material Notes noteringar RELEASE SWITCH DIMENSIONS Sheet1 A010031 tor c 10 07 2009 1 1 Tel 46 31 709 65 50 Fax 46 31...

Страница 10: ...DC 32VDC Max intermittent load 3A Cable glands max cable diameter 12 mm Terminals max cable area 2 5 mm2 POS 4 Cable 2 x min 0 75 mm2 screened Outer diameter max 10 mm POS 5 Cable 4 x min 0 75 mm2 scr...

Отзывы: