![Hammar HM-0600 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/hammar/hm-0600/hm-0600_installation-manual_3437436005.webp)
HK
-41702
COMPONENTS
PACKAGE
Part no.
HM-0600
1. One GRP holder with pre-installed metal spring holder. The GRP holder can
be mounted on port or starboard side of the ship and no change of the
metal spring holder is needed. Measurements and hole positions - please
check enclosed drawing.
2. One ERU (electric remote unit) with cord pre-installed on the metal holder.
The ERU cable is 1,5m long and shall be well strapped to the GRP holder in
order to avoid any damage by weather or wind.
3. One Release Switch in protective box to be mounted at the wheelhouse or
bridge, IP66 class. Colour: silky grey. If mounted outside it shall be protected
by an outer protective enclosure. Maximum diameter for cable 12mm. If
the Release Switch shall be mounted flush in a bridge control panel please
specify in the order - HM-0451 Release Switch for flush mounting. Measure
-
ments and hole position - please check enclosed drawing.
4. One connector box in marine grade plastic, IP66 class. Colour: steel grey.
Maximum diameter for cable 12mm. Measurements and hole positions -
please check enclosed drawing.
5. 20m cable from connector box to release switch, marine approved, scree-
ned 2 x 0,75mm2, diameter 8mm. Longer lengths can be supplied on
request by additional meter price. Maximum length of the installation is
150m. The Hammar products are designed to handle any voltage drop, so
there is no need to increase the cable dimensions more than our recom-
mendation.
Cable recommendations:
0 - 75m installation length: 2 x 0,75mm2
75 - 150m installation lenght: 2 x 1,5mm2.
Cables with a diameter larger than 12mm can not be handled in the cable
glands and terminal blocks. Electric power required is 24VDC emergency
power.
6. One manual safety pin in stainless steel.
7. One pilot line for loading the lifebuoy.
8. Installation manual and user guide.