background image

HK

-41702

TESTING THE MECHANICAL RELEASE FUNCTION

1.  Remove the manual safety pin holding the release cord.

2.  The Lifebuoy will be released and launched from the GRP holder.

TESTING THE ELECTRONIC RELEASE FUNCTION BY USING THE EMULATOR HM-0467

 

1.  Open the enclosure of the Emulator and attach two connection wires to the terminals on the Emulator. 

       (Do not use to much torque on the terminal screws)

2.  Push the push button on the circuit board to switch on the Emulator.  The red and the green LED on the circuit board shall light up 

simultaneously. The green LED will start flashing green and the device is ready to be used.

3. 

Open the Connector box (mounted close to the GRP holder) and disconnect the flexible cable of the H20 ERU. Connect the two 

connection wires from the Emulator to the terminals on the Connector box, were the flexible cable was mounted. (The polarity is not 

important).

The Emulator can be left without observation mounted to the Connector box, as the Emulator will hold the indication of the 

LED turning from green to red if activated until the device is reset manually.  

4.  Push the Release Switch (should be mounted on the bridge or inside the wheelhouse) to activate the output of the Lifebuoy Release 

unit. The Emulator’s LED will change from LED flashing green to LED flashing red if the output has been activated and the system is 

functional.  

DO NOT FORGET TO RECONNECT THE H20 ERU AND THE SAFETY PIN AFTER THE TEST!

TEST OF THE LIFEBUOY RELEASE SYSTEM

Содержание HM-0600

Страница 1: ...HK 41702 INSTALLATION MANUAL HM 0600 LIFEBUOY RELEASE SYSTEM Mk II Complete package for electric water release...

Страница 2: ...wing or the enclosed document Test of the Lifebuoy Release System 7 The ERU is pre installed The ERU must be marked with its expiry date Markings must be done solely by a manufacturer of liferafts or...

Страница 3: ...lease cord through the ERU hole with the pilot line Secure it with the manual safety pin 10 Connect the power to the Release Switch 11 The safety cover on the Release Switch shall be secured with some...

Страница 4: ...nector box mounted close to the GRP holder and disconnect the flexible cable of the H20 ERU Connect the two connection wires from the Emulator to the terminals on the Connector box were the flexible c...

Страница 5: ...M 0451 Release Switch for flush mounting Measure ments and hole position please check enclosed drawing 4 One connector box in marine grade plastic IP66 class Colour steel grey Maximum diameter for cab...

Страница 6: ...cuum operated HM 0650 with release cord and installation manual in English HM 0406 Replacement kit for LifeBuoy System MkI ERU electric water activation HM 0500 with release cord metal ring cable tie...

Страница 7: ...HK 41702 Sideview Backview Frontview Topview 190 780 958 510 650 60 800 160 60 670 680 540 M8 x5 GRP HOLDER DRAWING...

Страница 8: ...709 65 50 Fax 46 31 49 70 23 Drawn Ritad Checked Kontr Appr Godk nd Scale skala Repl Ers tter Date Datum dd mm yyyy Draw No Ritn nr Det Number ant Designation ben mn Sheet1 Notes noteringar Material...

Страница 9: ...Datum Repl Ers tter Scale skala Draw No Ritn nr Det Number ant Designation ben mn Material Notes noteringar RELEASE SWITCH DIMENSIONS Sheet1 A010031 tor c 10 07 2009 1 1 Tel 46 31 709 65 50 Fax 46 31...

Страница 10: ...DC 32VDC Max intermittent load 3A Cable glands max cable diameter 12 mm Terminals max cable area 2 5 mm2 POS 4 Cable 2 x min 0 75 mm2 screened Outer diameter max 10 mm POS 5 Cable 4 x min 0 75 mm2 scr...

Отзывы: