background image

Page 7 

Hamlet Solution Inset  

BURNING SOLID FUEL 

SOLID FUEL BURNING 

 

 

Set the grate t the ‘+’ position 

 

 

Ensure the ash pan is in position 

 

 

Set the air wash to one quarter open 

 

 

Set the primary air inlet  to fully open 

     See 

PRIMARY AIR 

Section opposite 

 

 

Light as normal with kindling or fire lighter 

 

 

If a gas poker is used be sure to remove it as 
soon as the fire is alight 

 

 

Close the fire door 

 

 

When the fire is well alight regulate the burning 
rate by controlling the primary air inlet control 

 

 

The air wash can be opened sufficiently to keep 
the door glass clean 

 

 

MIXED FUELS  

 

 

The grate can be set to either Wood or Coal 
position depending on the main percentage of 
the fuel to be burnt 

 

 

As per coal but allow addition secondary air 

 

 

The primary air inlet can be closed and burning 
regulated by means of the air wash above the 
door (s) 

 
ANTHRACITE  

 

Anthricite  is more difficult to keep in for long     
periods, consequently more care in setting the 
controls and some familiarisation is necessary 
when burning Anthracite. 
Use small size fuels (Stovesse or Small Nuts) 
Proceed as for manufactured smokless fuel. Leave 
the air inlet control open about a quarter or less. 
 

EXTENDED BURNING 

 

The appliance will burn for extended periods     
provided:- 

 

 

Sufficient fuel is placed in the firebox 

 

 

The controls are correctly set 

 

 

Excess draught is not present in the chimney 

 

 

The door is closed 

 

 

If the fire goes out with un burnt fuel in the    
firebox increase the air opening slightly, and 
vice versa. 

 

In The Morning 

 

Open the air controls fully until embers begin to 
glow brightly, then place pieces of fuel on the fire 
until it is well established. Complete re-fuelling can 
now be undertaken 

 

                 IMPORTANT 

 

Stop using the appliance if you smell 
fumes or see smoke escaping. 

 

If fume emission does persist, the following  
immediate actions should be taken : 

 

 

Open doors and windows to ventilate room. 

 

 

Let the fire die or extinguish and safely dispose 
of fuel from the appliance. 

 

 

Check for flue or chimney blockage, and clean if 
required. 

 

Seek expert advice from your HETAS         
registered installer. Do not attempt to re-light 
the fire until the cause of the fume emission 
has been identified and corrected. 

 

PRIMARY AIR 

 

Air enters the appliance through the control on the 
bottom of the fire door. The Hamlet Solution has a 
single control knob which slide left to right. Sliding 
the knob to the 

Right

 (+), will increase the amount 

of air intake to the stove. To decrease, push the 
slider to the 

Left

 (-)  

Fully Open Position 

Fully Closed Position 

Содержание Solution Inset 5

Страница 1: ...40 2004 Amd A2 2004 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE SOLUTION INSET Multi Fuel Grate Installation Instructions Rev 01 September 2009 Part No AFS1460 Solution Inset Shown With Multi Fuel G...

Страница 2: ...ar 4 Assembling the Grate 5 Fitting the Grate 6 Solid Fuel Burning 7 Final Factor Check List 8 Hamlet Solution Inset CONTENTS Page 2 Please note if you require any further information or assistance th...

Страница 3: ...Grate bar comb Extension 1 x AFS1413 Grate Bar 5 x AFS0001 Plus Minus bracket 1 x AFS1412 Inner Wood Cover Plates Includes Fixings 1 x AFS1404 Outer Wood Cover Plates Includes Fixings 1 x AFS1333 Wood...

Страница 4: ...ts as shown in Fig 3 Next fit the comb and comb extension bar as follows Feed the comb extension bar through the hole in the body of the stove from the outer face with the slotted end inside the stove...

Страница 5: ...mb extension though the stove body Section views are for clarity Fig 4b Slot and hole aligned vertically ASSEMBLY PROCEDURE Fig 4c Fig 4d Left and right end comb insertion Left hand end in left landin...

Страница 6: ...e with castings of the same type fitting as per the instructions on page 4 When re ordering replacement grate bar See page 3 of these instructions for the correct spare part code Fig 5 Fig 6 Fig 7 Woo...

Страница 7: ...r or less EXTENDED BURNING The appliance will burn for extended periods provided Sufficient fuel is placed in the firebox The controls are correctly set Excess draught is not present in the chimney Th...

Страница 8: ...ension Plus Minus Bracket I ve checked it and its O K Assembled By Checked by Final Factory Check list Stove Model Serial No Arada Ltd The Fire Works Weycroft Avenue Axminster Devon EX13 5HU United Ki...

Отзывы: