Figure 2: Fitting the flue outlet for a top flue configuration.
The flue pipe assembly is secured in place with four M5 bolts (supplied). Tighten
bolts diagonally and evenly to ensure full compression of the gasket but do not
over tighten.
Place appliance on the hearth and make sure that it is level and does not rock.
Connect the chimney ensuring all joints are sealed with fire cement.
Figure 3: Fitting the flue pipe inside the spigot.
Note : The flue pipe must be fitted inside the outlet spigot. Failure to do so
could result in the spillage of condensation running down the flue, (see figure 3)
BK575 Rev03