background image

 
 
 
 

WARNING 

 

IT IS A LEGAL REQUIREMENT THAT THE INSTALLATION OF ALL 

NEW OR REPLACEMENT, WOOD OR SOLIDFUEL HEATING  

APPLIANCES ARE REQUIRED TO OBTAIN BUILDING CONTROL 

APPROVAL FROM YOUR LOCAL AUTHORITY OR THE  

INSTALLATION WORK MUST BE CARRIED OUT THROUGH A 

GOVERNMENT APPROVED COMPETENT PERSONS SCHEME 

SUCH AS OPERATED BY HETAS. 

 

IF IN DOUBT, CONTACT HETAS LIMITED 

TELEPHONE  NUMBER : 0845 634 5626 

www.hetas.co.uk 

 

THIS STOVE MUST NOT BE CONNECTED  

TO A SHARED FLUE SYSTEM 

 

TO ALL USERS 

PETROLEUM COKE 

SOME OF WHOSE BRAND NAMES ARE 

CALCO’, ‘PETROCOKE’ AND ‘WONDERCO’

 

MUST  NOT BE BURNED IN THIS APPLIANCE 

 

BITUMINOUS HOUSE COAL  

SHOULD NEVER BE USED IN YOUR STOVE 

 

TO USE THESE FUELS WILL INVALIDATE  

THE APPLIANCE GUARANTEE.

 

 

IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION 

TELEPHONE NUMBER 0845 601 4406

 

www.solidfuel.co.uk 

Hamlet Camborne Deluxe Stoves 

Содержание BK055

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Operating Installation Manual BK055 Rev 06 November 2009 Part No AFS1297 RANGE OF STOVES Camborne Deluxe Camborne Deluxe Medium Pictured...

Страница 2: ...please contact the Hamlet retailer in your area or call our technical support department on 0844 8475107 Copyright 2008 Arada Ltd This booklet has copyright and may not be copied in whole or part or...

Страница 3: ...Chimney Sweeping 18 Door Glass 18 Outer Finish 18 Summer Storage Non Usage 19 Adjusting the Door Hinges 19 Disassemble The Airwash 20 Centre Fire Door Rope Replacement 20 Fire Door Rope Replacement 21...

Страница 4: ...HETAS IF IN DOUBT CONTACT HETAS LIMITED TELEPHONE NUMBER 0845 634 5626 www hetas co uk THIS STOVE MUST NOT BE CONNECTED TO A SHARED FLUE SYSTEM TO ALL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES AR...

Страница 5: ...odern equipment available It is a highly efficient and sophisticated piece of machinery and when properly installed and operated it should provide a lifetime of heating satisfaction Safety is the most...

Страница 6: ...Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 1 Fuel Retainer 2 2 2 2 2 Grate Bars 5 7 9 11 3 Throat plate 1 1 1 1 4 Flue Spigot 1 4 1 5 1 5 1 6 5 Hot Plate 1 4 1...

Страница 7: ...Camborne Deluxe Compact Camborne Deluxe Small Camborne Deluxe Medium Camborne Deluxe Large 9 Rear Liners 1 2 2 2 10 Side Liners 2 2 2 2 11 Rear Grate bar support 1 1 1 1 12 Comb Assembly comprising of...

Страница 8: ...t water add in boiler type 0 6 8 10 Max Oputput to Room kW 3 3 8 5 7 7 6 Max Oputput to Water kW 2 2 2 2 3 3 4 Height mm 505 530 552 552 Width mm 393 477 586 672 Depth mm 377 386 382 467 Height to Cen...

Страница 9: ...ll be installed on a floor with adequate load bearing capacity If the existing construction does not meet this prerequisite suitable measures e g load distributing plate should be taken to achieve it...

Страница 10: ...ware of this Failure to correct an over drawing flue will invalidate the warranty Please remember that chimney draught is dependent on four main factors Flue gas temperature Flue height Flue size Flue...

Страница 11: ...ng details on the chimney flue lining hearth and fireplace installation Approved Docu ment J of the Building Regulations for England Wales is available from The Stationary Bookshops and can also be vi...

Страница 12: ...shared flue system that serves any other heating appliance TYPICAL REAR FLUE OUTLET as per BS 8303 1 Maximum 150mm 6 Horizontal Flue Section Minimum 150mm 6 Diameter Flue Soot Door Fire Retardant Rop...

Страница 13: ...r Plate 1 5mm Thick Minimum Non Combustible Register Plate Minimum 1 5mm Thick Steel TYPICAL TOP FLUE OUTLET as per BS 8303 1 Typical Metal Insulated Chimney System Installed To The Chimney Manufactur...

Страница 14: ...and then lowering end marked L onto the low section of the comb see fig 3 The upper bar is fitted in a similar manner but with the end marked L inserted in the rear channel and the end marked H seate...

Страница 15: ...ner panels See Fig 6 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The long centre tab on the back edge rests on t...

Страница 16: ...2 mbar If Building Control Consent route is being sought please complete the check list on page 17 For a registered Competent Persons Scheme such as HETAS please complete the Certificate Of Complianc...

Страница 17: ...Profession Capacity Telephone No Address Postcode Signed Date Registered member of e g CORGI OFTEC HETAS NACE NACS 7 Hearth Form of construction new or existing 8 Inspection and testing after completi...

Страница 18: ...mportant that the flue ways flue pipe and chimney be cleaned prior to lighting the appliance after a prolonged shut down period DOOR GLASS The door glass should remain clear during normal burning Howe...

Страница 19: ...or catch This is quite normal and due to the settling of the casting The fire door can be re aligned as follows When the appliance is cold open the fire door so that it is at right angles to the front...

Страница 20: ...ng or replacement Refit using the reverse of this procedure Fig 11 Unscrew Control Knob Fig 12 Lifting Cover From Body Fig 13 Inner Slider Removal Hamlet Camborne Deluxe Stoves CENTRE FIRE DOOR ROPE R...

Страница 21: ...seal to length and glue into position Allow 30 minutes before refitting the door to the appliance FIRE DOOR GLASS REPLACEMENT In the event of the door glass being broken it can easily be replaced Ple...

Страница 22: ...amage and replace if necessary Clean the air slots within the door s casting and slider plate s Reassemble into the door and refit the control knob You will note that the slider can be locked to a sel...

Страница 23: ...vered in this manual please contact your Hamlet dealer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits so they can complete the service reco...

Страница 24: ...acturer For Further Details Advice On The Use Of Other Fuels For additional further advise on fuels please refer to HETAS Tel 0845 634 5625 or www hetas co uk or Solid Fuel Associa tion Tel 0845 601 4...

Страница 25: ...be minimised by burning hard for a short period 15 to 20 minutes twice a day Please Note To avoid chimney problems your appliance should not be burnt at a reduced burn rate without a period of fast b...

Страница 26: ...or household objects from falling embers The ash pan should be emptied at least twice a day or when the level of ash reaches the top of the ash pan On no account should the ash be allowed to build up...

Страница 27: ...to the Right as in Fig 20 AIR WASH SYSTEM The air wash has an internal sliding plate with slots housed in a cover plate and is located above the fire door Sliding the control knob to the right as far...

Страница 28: ...fe This operation should be carried out with the door doors closed to prevent dust escaping into the room Move up and down vigorously the riddling lever ash will fall into the ash pan beneath the grat...

Страница 29: ...t be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot WARNING Never attempt to open the fire door whilst the appliance is in use WITHOUT the use of t...

Страница 30: ...AOCXSL AOCSL AOCML AOCLL N A AOCSH AOCMH AOCLH ECB5 WBTRAY ECB7 WBTRAY ECB9 WBTRAY ECB11 WBTRAY 30 Aerosol Touch Up Paint Add On High Canopy Add On Low Canopy Add In Slab Boiler Wood Burning Upgrade K...

Страница 31: ...Large 1 Fuel Retainers AFS1190 AFS1192 AFS1191 AFS1240 2 Throat Plate AFS1018 AFS1019 AFS1020 AFS1241 3 Grate Bar Set AFS001 AFS001 AFS001 AFS002 4 Hot Plate AFS009B AFS009 AFS009 AFS012 5 Flue Spigo...

Страница 32: ...set AFS1279 AFS1279 AFS1279 AFS1279 14 Airwash Kit AFS1280 AFS1280 AFS1280 AFS1280 15 Fire Door Rope Kit with Rope glue AFS1021 AFS1021 AFS1021 AFS1021 16 Left Hand Fire Door Complete N A See Note1 AF...

Страница 33: ...Small Cam borne Deluxe Medium Cam borne Deluxe Large 20 Comb and Extension Bar AFS1274 AFS1276 AFS1291 AFS1301 21 Grate bar Support AFS1275 AFS1277 AFS1170 AFS1246 22 Stove Mitten AFS1285 AFS1285 AFS...

Страница 34: ...checked annually by a qualified heating engineer with documentation to be retained and produced in the event of a claim being made Claims are not valid where installation does not conform to appropria...

Страница 35: ...ion must be retained and produced in the event of a warranty claim This guarantee specifically does not cover accidental damage misuse wear tear The use of non Hamlet replacement parts will invalidate...

Страница 36: ...late Fuel Retainers Firebox Liners Throat Plate Air Wash Ash Pan Operating Tool Operating Installation Manual Stove Mitten Assembled By Checked by Date of Purchase Name and Address of Supplier Arada L...

Отзывы: