RFI Filter Wiring Details (See Figure 3.)
-
Black wire (top left) J4 from the top left terminal to terminal J1 on the Control
Board.
-
Blue wire (bottom left) J5 to terminal J2 on the Control Board.
-
White wire (top right) J3 splits to left terminal of cord socket plug and Reset
terminal of circuit breaker/On-Off switch.
-
Black wire (center right) J2 to center terminal of circuit breaker.
-
Yellow/Green striped wire (bottom right) J1 to motor chassis.
RFI Board Removal and Replacement
-
Disconnect wires from RFI board, mark if necessary or refer to wiring detail for
proper placement.
-
Remove the three Phillips screws and gently pull the RFI board off blender.
-
Replace with new board, and assemble in reverse order.