time is in element (dit)
lengths after the last
element you send, so
timing depends on keying
speed.
K
K[A,B,U,G,S] K {A,B,U,G,S}
Keying mode: Curtis A,
Curtis B, Ultimatic, Bug
(G), or Straight key
A, B, U, G, S
L
L[Y,N]
L {Y,N}
Automatic letter spacing
on or off
Y, N
M
M[Y,N,P]
M {Y,N,P}
Keying Monitor (sidetone)
Y (always on), N (never
on) or P (Paddles Only)
Y, N, P
N
N[n]
N {n}
Select message bank to be
assigned to the six top
panel buttons
1 - 5
P
DIT
Select dot paddle (paddle
reverse). Tap the paddle
you wish to use for dots.
NA
Q
Qnnnn
Q nnnn
QSO serial number
0 - 65535
QD
QD
Q nnnn
Decrement QSO number
by one
NA
QI
QI
Q nnnn
Increment QSO number
by one
NA
R
Rnn [nn]
R nn nn
Speed pot low and high
limit values. These are the
absolute low and high
limits; for example, to set
the speed control range
from 10 to 30 WPM, you
would send “R10 30”.
5 - 99
S
Snn
S nn
“Set” speed, WPM
5 - 99
T
Tn
T n
Paddle sense timing
0-8