General information regarding the CE marking

HAMEG instruments fulfi ll the regulations of the EMC directive. The 

conformity test made by HAMEG is based on the actual generic- and 

product standards. In cases where different limit values are applicable, 

HAMEG applies the severer standard. For emission the limits for 

residential, commercial and light industry are applied. Regarding the 

immunity (susceptibility) the limits for industrial environment have 

been used.

The measuring- and data lines of the instrument have much infl uence 

on emmission and immunity and therefore on meeting the acceptance 

limits. For different applications the lines and/or cables used may 

be different. For measurement operation the following hints and 

conditions regarding emission and immunity should be observed:

1. Data cables

For the connection between instruments resp. their interfaces and 

external devices, (computer, printer etc.) suffi ciently screened cables 

must be used. Without a special instruction in the manual for a reduced 

cable length, the maximum cable length of a dataline must be less than 

3 meters and not be used outside buildings. If an interface has several 

connectors only one connector must have a connection to a cable.

Basically interconnections must have a double screening. For IEEE-bus 

purposes the double screened cables HZ72S and HZ72L from HAMEG 

are suitable.

2. Signal cables

Basically test leads for signal interconnection between test point and 

instrument should be as short as possible. Without instruction in the 

manual for a shorter length, signal lines must be less than 3 meters 

and not be used outside buildings.

Signal lines must screened (coaxial cable - RG58/U). A proper ground 

connection is required. In combination with signal generators double 

screened cables (RG223/U, RG214/U) must be used.

3. Infl uence on measuring instruments.

Under the presence of strong high frequency electric or magnetic fi elds, 

even with careful setup of the measuring equipment an infl uence of 

such signals is unavoidable.

This will not cause damage or put the instrument out of operation. Small 

deviations of the measuring value (reading) exceeding the instruments 

specifi cations may result from such conditions in individual cases.

HAMEG Instruments GmbH

Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt
The HAMEG Instruments GmbH herewith declares conformity of the product 
HAMEG Instruments GmbH déclare la conformite du produit

Bezeichnung / Product name / Designation: 
  

 

Netzgerät

  

 

Power 

Supply

  

 

Alimentation

Typ / Type / Type: 

 

HM8143

mit / with / avec:    –
Optionen / Options / Options:   

mit den folgenden Bestimmungen / with applicable regulations / avec les directives 
suivantes

 

EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG

 

EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC

 

Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE

Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE

Angewendete harmonisierte Normen / Harmonized standards applied / Normes 
harmonisées utilisées

Sicherheit / Safety / Sécurité
EN 61010-1:2001 (IEC 61010-1:2001)
Überspannungskategorie / Overvoltage category / Catégorie de surtension: II

Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2

 Hersteller 

HAMEG 

Instruments 

GmbH 

KONFORMITÄTSERKLÄRUNG 

 

 

Manufacturer 

Industriestraße 6 

DECLARATION OF CONFORMITY 

 

Fabricant 

D-63533 Mainhausen 

DECLARATION DE CONFORMITE

Elektromagnetische Verträglichkeit / Electromagnetic compatibility / 
Compatibilité électromagnétique

EN 61326-1/A1 Störaussendung / Radiation / Emission: 
Tabelle / table / tableau 4; Klasse / Class / Classe B.

Störfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1. 

EN 61000-3-2/A14 Oberschwingungsströme / Harmonic current emissions / Émissions 
de courant harmonique: Klasse / Class / Classe D.

EN 61000-3-3 Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / 
Fluctuations de tension et du fl icker.

Datum / Date / Date 
05. 06. 2006 

 

 

Unterschrift / Signature /Signatur 

  

 

 

Manuel 

Roth

  

 

 

Manager

G e n e r a l   i n f o r m a t i o n   r e g a r d i n g   t h e   C E   m a r k i n g          

Содержание HM8143

Страница 1: ...A r b i t r a r y P o w e r S u p p l y H M 8 1 4 3 Manual 99 Washington Street Melrose MA 02176 Fax 781 665 0780 TestEquipmentDepot com...

Страница 2: ...uence of such signals is unavoidable This will not cause damage or put the instrument out of operation Small deviations of the measuring value reading exceeding the instruments speci cations may resul...

Страница 3: ...ies 23 Linear power supplies 23 Switched mode power supplies SMPS 23 Parallel and series operation 23 Current limit 24 Electronic fuse 24 Introduction to the operation 24 Operation modes 24 Constant v...

Страница 4: ...ion 10 mV 1 mA Arbitrary waveform power supply 1024 points 12 bit Tracking mode for 30 V outputs External modulation of output voltages Electronic load up to 60 W per channel max 2 A SENSE lines Multi...

Страница 5: ...ry Function Channel I only Number of points 1024 Resolution 12 Bit Parameters of points Dwell time and Voltage Dwell time 10 s 60 s Repetition rate 1 255 and continuous Inputs Modulation input BNC soc...

Страница 6: ...nd guarantee operation without any danger to the operator According to safety class 1 requirements all parts of the housing and the chassis are con nected to the safety ground terminal of the power co...

Страница 7: ...e petrol ether Displays and windows may only be cleaned with a moist cloth Do not use alcohol solvents or paste Under no cir cumstances any fluid should be allowed to get into the instrument If other...

Страница 8: ...it CURRENT pushbutton and LED Setting of current limit via frontpanel By pushing the but ton the setting function is active and the appertaining LED is lit Rotary knob Parameter setting of voltage and...

Страница 9: ...ut voltage is recti ed smoothed and then chopped The capacitance values needed here for ltering the 100 resp 120 Hz ripple are higher due to the lower voltage All SMPS feature a very much higher ef ci...

Страница 10: ...STOP STOP Introduction to the operation First time operation Please observe especially the following notes The line voltage indicated on the rear panel corresponds to the available line voltage also t...

Страница 11: ...ermit easy triggering of an oscilloscope connected to the output of the HM8143 especially in arbitrary mode the in strument is equipped with a BNC socket TRIGGER IN OUT on its rear panel This is con g...

Страница 12: ...instrument by short cir cuits or overheating Current limit If one of the output voltages is short circuited the current li miter automatically keeps the current from rising beyond the programmed maxim...

Страница 13: ...I2 0 123 A RU1 RU2 Format RU1 or RU2 Reply U1 12 34V or U2 12 34V Function The voltage values sent back by the HM8143 are the programmed voltage values Use the MUx com mands to query the actual values...

Страница 14: ...nal proceeds internal This also has the effect of switching off the outputs Pressing this button again switches the outputs of the power supply on The waveform generation starts either after the recei...

Страница 15: ...epeat this sequence 10 times The required data table is as follows ABT A10 00_B30 00_A30 00_725 67_002 00_002 00_N10 or ABT A10 00_B30 00_A30 00_725 67_002 00_002 00_N10 2 x 100 s 2 00V 100 ms 25 67 V...

Отзывы: