background image

Subject to change without notice

21

 Specifications HM6050-2

Frequency range:

9 kHz to 30 MHz

Network inductance:

Z = 50  II (50 µH + 5 )
error < 20% acc. to VDE 0876T1

Max. current:

2 x 16 A continuous

Voltage:

230 V~ at 50/60 Hz
(factory setting)

Artificial hand:

220 pF + 511

PE simultating network:

50  II 50 µH

 Connections

Front panel:
Artificial hand:

banana jack 4 mm
(Artificial Hand)

Ground:

banana jack 4 mm

DUT:

Female AC supply voltage output with PE

Test signal output:

50  BNC jack (Test Receiver)

Rear panel:
Power:

line cable 3 x 1,5 mm

2

male with PE

Ground:

Alu-Block with tread 4 mm

40 x 20 x 20 mm

RS-232 Interface:

9-pin Sub-D, female

 Transient  Limiter

Frequency range:

150 kHz – 30 MHz

Transmission less:

f = 150 kHz – 30 MHz 
a =10 dB + 1,5/ -0,5dB
f <1 kHz – a>90 dB
f  >100  MHz – a>50  dB

Max. Input voltage:

bei P = 2 W (average) ^

=

   +33 dBm

U = ±50 V

DC

Standing wave ration (VSWR):

1,5:1 or better

 Miscellaneous

Ambient temperature:

10 °C to 40 °C

Power:

230 V / 115 V, 50 – 60 Hz

Safety:

Safety class I (IEC 1010-01/VDE 0411)

Dimensions (W x H x D):

285 x 125 x 380 mm

Weight:

6 kg

Color:

technobrown

Содержание HM6050-2

Страница 1: ...d a n c e S t a b i l i z a t i o n N e t w o r k H M 6 0 5 0 2 Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com Hameg H...

Страница 2: ...50 2 20 Specifications 21 Operating Manual 22 Introduction 22 Used Symbols 22 Operation according to rules 22 Safety 22 Replacement of fuses 23 Operating conditions 24 Warranty and repair 24 Operating...

Страница 3: ...uction in the manual for a reduced cable length the maximum cable length of a dataline must be less than 3 meters If an interface has several connectors only one connector must have a connection to a...

Страница 4: ...WG EMC Directive 89 336 EEC amended by 91 263 EWG 92 31 EEC Directive EMC 89 336 CEE amend e par 91 263 EWG 92 31 CEE Directriz EMC 89 336 CEE enmendada por 91 263 CE 92 91 CEE Niederspannungsrichtlin...

Страница 5: ...tly to the LISN Inside the LISN the power lines are terminated with a well defined impedance network against each other and against ground The HM6050 2 Line Impedance Sta bilization Network LISN in pr...

Страница 6: ...output with PE Test signal output 50 BNC jack Test Receiver Rear panel Power line cable 3 x 1 5 mm2 male with PE Ground Alu Block with tread 4 mm 40 x 20 x 20 mm RS 232 Interface 9 pin Sub D female Tr...

Страница 7: ...ns It conforms to the regulations as defined in CISPR Publ 16 or EN55011 Safety This instrument has been designed and tested in accordance with VDE 0411 Part 1 Safety requirements for electrical equip...

Страница 8: ...M6050 2 contains a fuse Ex factory the HM6050 2 is set to 230V 10 50 60Hz If the instrument shall operate at a mains voltage of 115 V 10 the wire bridges have to be changed by soldering Insert or repl...

Страница 9: ...ly failures are detected After burn in a thorough test of all functions and of quality is run all specifications and operating modes are checked In case of reclamations during the two years warranty p...

Страница 10: ...nd connection according to Class 1 2 Ground jack This jack is used for testing DUTs which don t have a protective ground line in their AC power cable but do have a separate ground connection The DUT s...

Страница 11: ...tached Test Receiver s or Spectrum Analyzer s input circuitry from high transient voltages After pushing button 10 the transient limiter circuit will be bypassed A blinking red LED 12 indicates this o...

Страница 12: ...onnected between the ground block and the chamber s shielding material VDE 0877 Part1 16 RS 232 interface Safety hints Attention All interface lines are galvanic coupled to the LISN As mentioned in pa...

Страница 13: ...upper case letters Command Function Indication R Remote control enabled RM LED lit O Local control RM LED dark P Protect ground line sim circuit on PE LED lit p Protect ground line sim circuit off byp...

Страница 14: ...hich may be touched by the user lie on a dangerous high voltage level EMC measurement procedures for LISN HM6050 2 Measurements have to be performed according to the VDE regulations VDE 0877 Part 1 Af...

Отзывы: