General information regarding the CE marking
General information regarding the CE marking
HAMEG instruments fulfi ll the regulations of the EMC directive. The conformity test made by HAMEG is based on the actual
generic- and product standards. In cases where different limit values are applicable, HAMEG applies the severer standard.
For emission the limits for residential, commercial and light industry are applied. Regarding the immunity (susceptibility)
the limits for industrial environment have been used. The measuring- and data lines of the instrument have much infl uence
on emmission and immunity and therefore on meeting the acceptance limits. For different applications the lines and/or
cables used may be different. For measurement operation the following hints and conditions regarding emission and im-
munity should be observed:
1. Data cables
For the connection between instruments resp. their interfaces and external devices, (computer, printer etc.) suffi ciently
screened cables must be used. Without a special instruction in the manual for a reduced cable length, the maximum cable
length of a dataline must be less than 3 meters and not be used outside buildings. If an interface has several connectors
only one connector must have a connection to a cable. Basically interconnections must have a double screening. For IEEE-
bus purposes the double screened cables HZ72S and HZ72L from HAMEG are suitable.
2. Signal cables
Basically test leads for signal interconnection between test point and instrument should be as short as possible. Without
instruction in the manual for a shorter length, signal lines must be less than 3 meters and not be used outside buildings.
Signal lines must screened (coaxial cable - RG58/U). A proper ground connection is required. In combination with signal
generators double screened cables (RG223/U, RG214/U) must be used.
3. Infl uence on measuring instruments
Under the presence of strong high frequency electric or magnetic fi elds, even with careful setup of the measuring equip-
ment an infl uence of such signals is unavoidable. This will not cause damage or put the instrument out of operation. Small
deviations of the measuring value (reading) exceeding the instruments specifi cations may result from such conditions in
individual cases.
4. RF immunity of oscilloscopes
4.1 Electromagnetic RF fi eld
The infl uence of electric and magnetic RF fi elds may become visible (e.g. RF superimposed), if the fi eld intensity is high. In
most cases the coupling into the oscilloscope takes place via the device under test, mains/line supply, test leads, control
cables and/or radiation. The device under test as well as the oscilloscope may be effected by such fi elds. Although the in-
terior of the oscilloscope is screened by the cabinet, direct radiation can occur via the CRT gap. As the bandwidth of each
amplifi er stage is higher than the total –3dB bandwidth of the oscilloscope, the infl uence RF fi elds of even higher frequen-
cies may be noticeable.
4.2 Electrical fast transients / electrostatic discharge
Electrical fast transient signals (burst) may be coupled into the oscilloscope directly via the mains/line supply, or indirectly
via test leads and/or control cables. Due to the high trigger and input sensitivity of the oscilloscopes, such normally high
signals may effect the trigger unit and/or may become visible on the CRT, which is unavoidable. These effects can also be
caused by direct or indirect electrostatic discharge.
HAMEG Instruments GmbH
KONFORMITÄTSERKLÄRUNG
DECLARATION OF CONFORMITY
DECLARATION DE CONFORMITE
Herstellers
HAMEG Instruments GmbH
Manufacturer
Industriestraße
6
Fabricant
D-63533
Mainhausen
Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt
The HAMEG Instruments GmbH herewith declares conformity of the product
HAMEG Instruments GmbH déclare la conformite du produit
Bezeichnung / Product name / Designation:
Oszilloskop/Oscilloscope/Oscilloscope
Typ / Type / Type:
HM504-2
mit / with / avec:
–
Optionen / Options / Options:
–
mit den folgenden Bestimmungen / with applicable regulations / avec les
directives suivantes
EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG
EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE
Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE
Angewendete harmonisierte Normen / Harmonized standards applied / Normes
harmonisées utilisées
Sicherheit / Safety / Sécurité
EN 61010-1: 2001 / IEC (CEI) 1010-1: 2001
Messkategorie / Measuring category / Catégorie de mesure: I
Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2
Elektromagnetische Verträglichkeit / Electromagnetic compatibility /
Compatibilité électromagnétique
EN 61326-1/A1 :1997 + A1:1998 + A2 :2001/IEC 61326 :1997 + A1 :1998 + A2 :2001
Störaussendung / Radiation / Emission: Tabelle / table / tableau 4; Klasse / Class /Classe
B
.
Störfestigkeit / Immunity / Imunitee: Tabelle / table / tableau A1.
EN 61000-3-2/A14
Oberschwingungsströme / Harmonic current emissions / Émissions de courant
harmonique: Klasse / Class / Classe D.
EN 61000-3-3
Spannungsschwankungen u. Flicker / Voltage fl uctuations and fl icker / Fluctuations
de tension et du fl icker.
Datum / Date / Date
Unterschrift / Signature / Signatur
25.6.2003
G.
Hübenett
Product
Manager
cable HZ72 from HAMEG is suitable.
Содержание HM504-2
Страница 2: ......
Страница 3: ...O s c i l l o s c o p e H M 5 0 4 2 Manual English...
Страница 39: ...37 Subject to change without notice Front Panel HM504 2...
Страница 40: ......
Страница 41: ...LEER...