background image

 

 

 

WARNING:

 

This unit emits ultraviolet (UV) radiation that is harmful to humans.  Avoid exposure 

to the direct or reflected output beam.  Make certain that the appropriate output beam shields and 

optics are in place prior to energizing the unit.  All interlocks must be satisfied prior to operation; 

failure to do so may lead to hazardous conditions. 

 

 

CAUTION: 

The TLS-EQ-9 emits dangerous levels of UV radiation.  Even short exposures to 

skin or eyes may cause burns.  Ensure that only authorized personnel are in the vicinity of source 

during operation.  Personnel in vicinity of operating source should wear protective eyewear, 

clothing, and gloves.  Lighted UV warning lights and signs posted on doors to lab areas may help 

prevent accidental exposure.   

 

 

 

 

WARNING:

 

The TLS-EQ-9 utilizes an internal Class 4 IR laser capable of causing severe injury 

to eyes or skin.  Do not open or attempt to service this unit.  Contact Energetiq regarding any 

problems with the unit. 

 

 

WARNING: 

When working near the emitted light, always wear protective devices (conforming to ISO 

4007/4849/4850/4854/4855 or equivalent regulations). The lamp installed in this housing emits intense ultraviolet rays, 

which are harmful to the eyes and skin. Looking directly into the emitted light or allowing the light to fall on the skin will 

damage eyesight or cause skin burns.

  

 

WARNING: 

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment 

may be impaired. 

The power supply must be properly grounded by the outlet to prevent electrical shocks. 

Securely plug in the power supply connector to avoid looseness or play. Loose connections may result in 

faulty operation. 

2.2.  Definition of equipment and document symbols and designations 

Do not operate the TLS-EQ-9 if the covers are removed or is defective in any way.  Contact Energetiq if any 

problems with the equipment are suspected. 

The TLS-EQ-9 utilizes a quartz lamp containing a high-pressure gas fill.  Explosion of the lamp and 

possible injury from flying fragments can occur if the lamp is mishandled.   

Do not open the enclosure of either the Lamp or the Controller.  Dangerous invisible infrared laser 

beams and hazardous voltages exist inside the Lamp.  

Opening the chassis both voids the warranty and 

exposes the user to dangerous radiation and hazardous voltages. 

 

 

 

 

CAUTION: 

controls or adjustments or performance of procedures other than those specified 

herein may result in hazardous radiation exposure

.

 

 

 

 

WARNING:

 

Invisible laser radiation avoid eye or skin exposure to direct or scattered radiation 

Class 4 laser product 

Содержание Energetiq LDTLS TLS-EQ-9

Страница 1: ...Model TLS EQ 9 Laser Driven Tunable Light Source LDTLS Operation Manual Revision 3 June 2022 Part Number DOC 9220...

Страница 2: ...information including drawings schematics and specifications contained in this document are the property of Energetiq and shall not be reproduced in whole or in part without the written consent of En...

Страница 3: ......

Страница 4: ...1 TLS EQ 9 Main Housing 6 3 2 2 Internal Components 8 3 3 Optical Performance 9 3 4 Physical Specifications 9 3 5 Utility requirements 9 3 6 Remote Interface 9 3 7 External interlock connection 10 4...

Страница 5: ...8 Warranty 21 9 Appendix 21 9 1 Dimensional Drawings 21 9 2 Environmental Requirements 22 9 3 I O Connector Pin Assignment 22 9 4 RS 485 Interface Pin Assignment 22 9 5 Remote Interface Schematic 23 9...

Страница 6: ...losed space We suggest purging any beam transport space with dry nitrogen gas The TLS EQ 9 source must also be cabled correctly and connected to a power source with a protective earth ground prior to...

Страница 7: ...es and skin Looking directly into the emitted light or allowing the light to fall on the skin will damage eyesight or cause skin burns WARNING If the equipment is used in a manner not specified by the...

Страница 8: ...EQ 9 laser product is designated as Class 1 during all normal operation The parameters of the non accessible internal laser are given below in Table 1 Parameter Value Wavelength 974 nm Emission Type C...

Страница 9: ...tion Labels and Safety Notifications Label Picture Description 1 Manufacturer s identification label on lamp house gives the manufacturer s name and address and the model serial number and date of man...

Страница 10: ...ircuit must be connected to enable the operation of the unit Should the interlock connection open during operation or standby the source is immediately disabled and all light output from the aperture...

Страница 11: ...immediately Do not attempt to substitute any parts There are no user serviceable parts inside the TLS EQ 9 Lamp House Save the pallet and all packing materials If it becomes necessary to ship the sys...

Страница 12: ...for 12VDC power 4 RS 485 I O connector Provides access to control and status signals 5 Status indicator LEDs Light emitting diodes LEDs on the back of the TLS EQ 9 housing provide status information S...

Страница 13: ...rature too high Laser power not reaching setpoint Laser temperature fault Internal power supply voltage low LAMP MODULE FAULT One of the following has occurred in the Lamp House module Control Cable n...

Страница 14: ...s Dimensions H x W x D Lamp House 231 7 x 355 6 x 266 7 mm 9 125 x 14 0 x 10 5 in Weight 7 9 kg 17 5 lb 3 5 Utility requirements Lamp Controller Unit Electrical Electrical 12VDC 140W Cooling Fan 30 CF...

Страница 15: ...any connections 4 1 1 Electrical Power The TLS EQ 77H requires 100 240 V 50 60 Hz input voltage Power consumption is 350 W maximum during normal operation Some OEM versions have higher current require...

Страница 16: ...imit gas flow The lamp requires 1 8 OD tubing and the retroreflector requires 4mm OD tubing 2 Insert the Interlock Connector Bypass in the Remote Control 3 Connect the Remote Control to the Remote Con...

Страница 17: ...20 150 seconds the igniter will be turned on automatically and the plasma will ignite The LAMP ON LED will be lit The duration of the warm up time 20 150 seconds will depend on the temperature and pre...

Страница 18: ...25mm and 0 5mm is available To change the slits slide the installed slit upward to remove it from the monochromator as shown below in Figure 5 To install slide the slit into the same location The mon...

Страница 19: ...20X B Gloves Nitrile rubber TechNiGlove replace X with digit for desired size A R LG 1 Laser safety glasses ThorLabs A R 7 1 1 3 Supplies and Tools Required Part Number Description Quantity 843 R USB...

Страница 20: ...y to the Lamp power input connector o Connect the Monochromator Power Supply to the TLS EQ 9 Monochromator power connector o Connect the USB cable to the PC and TLS EQ 9 Monochromator control USB conn...

Страница 21: ...16 2 3 Zero the power meter Power Meter functions are shown at left Turn Power Meter ON...

Страница 22: ...length to 500nm 5 Turn the Remote Control OPERATE switch on Clear any faults if required by turning the OPERATE switch OFF ON The LASER ON LED will illuminate Wait for the LAMP ON LED to illuminate Wa...

Страница 23: ...TLS EQ 9 At the chosen wavelength of 500nm the expected minimum output is 1 3mW If the output is 1 3mW or greater no adjustment is necessary Stop here If the output is below 1 3mW continue with the a...

Страница 24: ...ne which direction results in an increase in the meter reading Continue turning in the appropriate direction until the meter reading is maximized 11 After turning the first adjustment screw move to th...

Страница 25: ...ON position then to the OFF position The unit will not turn on if a fault condition exists If all the interlocks are OK and either the lamp or controller interlock faults will not clear please contac...

Страница 26: ...rgetiq Technology Inc s warranty for the product is set forth in Section 5 of Energetiq Technology Inc s standard terms and conditions found at www energetiq com 9 Appendix 9 1 Dimensional Drawings TL...

Страница 27: ...RNAL INTERLOCK apply 5V referenced to digital common to close interlock and allow operation Status Indicators Outputs LAMP ON 1 Pulled to digital common when ON LASER ON 2 Pulled to digital common whe...

Страница 28: ...e power Laser power can be increased or decreased in increments of 0 5 of full scale The following describes the serial commands and their functions 0 1uF 100 Pins 1 2 3 4 Pins 6 7 8 9 Pin 5 499 Pins...

Страница 29: ...e Power XX X Q Queries the value of the present laser power setpoint in of full scale Power XX X F Resets laser power setpoint to factory default value Power XX X B Saves present settings to flash mem...

Страница 30: ...sion History Rev Effective Date Description of Change 1 09 Sep 2019 Initial release 2 19 Nov 2020 Updated labels and CE Declaration of Conformity 3 28 Jun 2022 Document style format labels and complia...

Страница 31: ...26 Energetiq Technology Inc 205 Lowell St Wilmington MA 01887 Phone 1 781 939 0763 Fax 1 781 939 0769 Email info energetiq com Website www energetiq com DOC 9220 Rev 3 6 22...

Отзывы: