4
Specifications:
Measuring range for DC voltages V
Set range
Measuring levels
Accuracy
200 mV
100 µV
+ - (0,5 % +5)
2000 mV
1 mV
+ - (0,8 % +5)
20 V
10 mV
+ - (0,8 % +5)
200 V
100 mV
+ - (0,8 % +5)
Max. 250 V
1 V
+ - (1,0 % +5)
Measuring range for AC voltages V ~
Set range
Measuring levels
Accuracy
200 V
100 mV
+ - (1,2 % +10)
Max. 250 V
1 V
+ - (1,2 % +10)
Measuring range for direct current A
Set range
Measuring levels
Accuracy
200 µA
0,1 µA
+ - (1,0 % +5)
2000 µA
1 µA
+ - (1,0 % +5)
20 mA
10 µA
+ - (1,0 % +5)
Max. 200 mA
100 µA
+ - (1,2 % +5)
Max. 10 A
10 mA
+ - (2,0 % +5)
Overvoltage protection: Fuse F1: 250mA/250V, fast; Fuse F2: 10A/250V fast
Voltage drop during measurements: 200 mV
Measuring range for resistance
Ω
Set range
Measuring levels
Accuracy
200
Ω
0,1
Ω
+ - (1,0 % +5)
2000
Ω
1
Ω
+ - (0,8 % +5)
20 k
Ω
10
Ω
+ - (0,8 % +5)
200 k
Ω
100
Ω
+ - (0,8 % +5)
2000 k
Ω
1 k
Ω
+ - (1,2 % +5)