background image

                                     

             

 

 

 

 

 

 

 

 

 

 

 

This Page intentionally left as blank

Содержание HAL-HPC300

Страница 1: ...HAL HPC300 Handheld Particle Counter Operational Manual 625 E Carroll Avenue Glendora CA 91741 USA Phone 510 579 8540 Fax 626 963 7302 Info haltechnologies com http haltechnologies com...

Страница 2: ...This Page intentionally left as blank...

Страница 3: ...ent Bring you attention about the features of the instrument Unpacking and Inspection Inspect the receiving package and notify the shipper immediately if there appears to be susceptible damage during...

Страница 4: ...e specified limits Technical Support and Warrantee Within a year from the date purchased the manufacturer will provide free technical support and software upgrade For additional help please contact in...

Страница 5: ...1 2 Features 7 II Basic Operation 9 2 1 Handheld Unit 9 2 2 Control Panel 11 2 3 Operational Windows 11 2 3 1 Startup Page 11 2 3 2 Measuring Window 12 2 3 3 Browsing Window 16 2 3 4 Setting Window 18...

Страница 6: ...ing data real time printing software upgrading and battery charging etc In addition to USB and RS232 interfaces the RJ45 interface allows users to conduct the remote sampling away from the sampling lo...

Страница 7: ...mpling Average of multiple times of measurements External digital temperature and humility sensors to assure accurate measurement Up to 26 location labels of measurements No less than 6 hours of conti...

Страница 8: ...w calibration 5 insufficient battery Communication Speed USB 12Mbps RJ45 100Mbps RS 232 9600bps Power Li ion polymer Battery 7 4V 2800mAH or AC adapter AC input 100 240V DC output 9V 1 5A Max Operatin...

Страница 9: ...II Basic Operation 2 1 Handheld Unit Figure 1 Front View of the Handheld Set Temperature Relative Humidity Probe Interface Power Switch Back Lit LCD Display Air Intake Control Panel...

Страница 10: ...to the USB interface of a computer COM port Connect to the printer or serial port of a computer POWER An AC adapter plug in port Thread bore is used for a tripod to minimize a human affect on the ste...

Страница 11: ...r about 2 seconds to turn off the instrument After about 8 minutes standby or no operation the instrument will shut off automatically to save the power RUN STOP Start or stop a measurement operation M...

Страница 12: ...t and conditions according to the unit setting One may wish to change the setting before the measurement run by pressing up or down arrow to enter into the Setup Window page An example of the Measurin...

Страница 13: ...d The sound can only be quieted by turning off the instrument Flashing of the sensor error indicates that the sensor is dirty A zero count filter attached to the air sampling intake may clean the sens...

Страница 14: ...in a unit volume under the accumulative situation The unit volume may be set Counts per Liter Counts per Cubic Meter Counts Cu M or Counts per Cubic Foot Counts Cu Ft Sample Time SampTime Sample time...

Страница 15: ...date and time is always displayed in the format of month day year and hour minute second respectively Date and time can be changed in the Setting window If the instrument is set as the manual saving m...

Страница 16: ...he user to browse print or delete historic data In the Browsing window press ENTER keypad to enter into the last saved data record Then use the arrow keypad to scroll through the stored data Use keypa...

Страница 17: ...a CUMU Displays the mode that data was saved in CUMU Record Format as number of saved data total number of stored Data e g 0015 0110 SampTime Displays the length of sampling time of a saved data Tempe...

Страница 18: ...ve up or down for highlighted selection Press BACK keypad to return to the previous Browsing window Press ENTER keypad to confirm the print or delete selection Toggle between Yes and No selection with...

Страница 19: ...o confirm the parameter s setting Press BACK keypad to back to the previous window Figure 13 Setting Window page Sizes The user may change the size of the middle channel selected from 0 5 m 0 7 m 1 0...

Страница 20: ...pressing the RUN keypad and the beginning of the actual sample measurement The user also has the option of setting a time interval between two consecutive sample runs when the Count Mode see below is...

Страница 21: ...e touched The factory setting for this function is set to Off BackLight The back light of LCD display may be configured to stay on for the following lengths of time On Off 5 seconds 15 seconds 30 seco...

Страница 22: ...obe into water Zero Count Filter and Purge Test The instrument must be periodically cleaned using the purge filter Following are instructions to purge the unit 1 Unscrew the iso kinetic probe and atta...

Страница 23: ...on the setup executable provided on the CD ROM and be sure that your com settings are set to either USB Downloaded data could be managed deleted and saved as a Microsoft Excel file format Use the data...

Страница 24: ...Functional LED Function Push Button Power LED Power Push Button AC Adaptor Socket Beeper Functional LED Function Push Button Power LED Power Push Button AC Adaptor Socket Beeper Paper Loading Cover P...

Страница 25: ...ning Power LED turns red when the battery below the normal usage level Auto sleep mode The printer goes to sleep mode after 10 seconds if no printing command is received The printer will go to working...

Страница 26: ...reen Waiting for recediving data and ready to print Flash green Paper feeding Functional LED Flash red No paper Sound high and low Printer turn on Sound low and high Printer turn off Sound high three...

Страница 27: ...ration in an un specified environmental condition Abnormal operation due to instrument needing calibration Limitation of Warranty A Hal Technology warrants that all equipment shall be free from defect...

Страница 28: ...medies granted under this Section may at Hal Technology s option be terminated C Warranty repairs shall be completed at a Hal Technology authorized service location by an authorized service technician...

Страница 29: ...eturn shipping costs during the warranty period Buyers may select a faster method of shipment at their own expense Contact HAL TECHNOLOGY LLC 625 E Carroll Avenue Glendora CA 91741 USA Phone 510 579 8...

Страница 30: ...User Registration Form Company _____ Contact Person ______________ Address ______ ______ __ City ____State Province Country _____ Postal Code _________ Phone ________________ Fax __________________ E...

Отзывы: